검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 315

        23.
        2022.10 구독 인증기관·개인회원 무료
        Regulations on the concentration of boron discharged from industrial facilities, including nuclear power plants, are increasingly being strengthened worldwide. Since boron exists as boric acid at pH 7 or lower, it is very difficult to remove it in the existing LRS (Liquid Radwaste System) using RO and ion exchange resin. As an alternative technology for removing boron emitted from nuclear power plants, the electrochemical boron removal technology, which has been experimentally applied at the Ringhal Power Plant in Sweden, was introduced in the last presentation. In this study, the internal structure of the electrochemical module was improved to reduce the boron concentration to 5 mg/L or less in the 50 mg/L level of boron-containing waste liquid. In addition, the applicability of the electrochemical boron removal technology was evaluated by increasing the capacity of the unit module to 1 m3/hr in consideration of the actual capacity of the monitor tank of the nuclear power plant. By applying various experimental conditions such as flow rate and pressure, the optimum boron removal conditions using electrochemical technology were confirmed, and various operating conditions necessary for actual operation were established by configuring a concentrated water recirculation system to minimize secondary waste generation. The optimal arrangement method of the 1 m3/hr unit module developed in this study was reviewed by performing mathematical modeling based on the actual capacity of monitor tank and discharge characteristics of nuclear power plant.
        24.
        2022.10 구독 인증기관·개인회원 무료
        For Dry Storage of Spent Nuclear Fuel (SNF), all moisture must be removed from the dry storage canister through subjected to a drying process to ensure the long-term integrity. In NUREG-1536, the evacuation of most water contained within the canister is recommended a pressure of 0.4 kPa (3 torr) to be held in the canister for at least 30 minutes while isolated from active vacuum pumping as a measure of sufficient dryness in the canister. In the existing drying process, the determination of drying end point was determined using a dew point sensor indirectly. Various methods are being studied to quantify the moisture content remaining inside the canister. We presented a moisture quantification method using the drying process variables, like as temperature, pressure, and relative humidity operation data. During the drying process, it exists in the form of a mixed gas of water vapor and air inside the canister. At this time, if the density of water vapor in the mixed gas discharged out of the canister by the vacuum pump is known, the mass of water removed by vacuum drying can be calculated. The canister is equipped with a pressure gauge, thermometer and dew point sensor. The density of water vapor is calculated using the pressure, temperature and relative humidity of the gas obtained from these sensors. First, calculate the saturated water vapor pressure, and then calculate the humidity ratio. The humidity ratio refers to the ratio of water vapor mass to the dry air mass. After calculating the density of dry gas, multiply the density by the humidity ratio to calculate the density of water vapor (kg/m3). Multiply the water vapor density by the volume flow (m3/s) to obtain the mass value of water (kg). The calculated mass value is the mass value obtained per second since it is calculated through the flow data obtained every second, and the amount of water removed can be obtained by summing all the mass values. By comparing this value with the initial moisture content, the amount of moisture remaining inside the canister can be estimated. The validity of the calculations will be verified through an experimental test in the near future. We plan to conduct various research and development to quantify residual water, which is important to ensure the safety of the drying process for dry storage.
        25.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has been conducted to investigate the North Korea water supply system. For this purpose, laws and regulations concerning the North Korea water utilities were analyzed. According to this study, the water supply system of North Korea is similar to that of South Korea. The major difference between these two systems lies in the national water supplier: South Korea has the national water supplier as well as the municipal suppliers, while there is no national water supplier in North Korea. It is noted that the North Korean water utilities depend on outside suppliers for resources necessary for water production such as electricity, chemicals, spare parts, etc. This could damage the North Korean water utilities. If required resources were not delivered properly (deficient quantity and/or at delayed timing), the water suppliers would encounter difficulties in water production.
        4,000원
        27.
        2022.05 구독 인증기관·개인회원 무료
        Activated corrosion products deposited on the reactor coolant system in a nuclear power plant should be removed to reduce the radiation exposure to workers. Chemical decontamination processes using organic acids have been widely applied to remove the activated corrosion products. However, they are highly corrosive to the base metal and generate a considerable amount of ion exchange resin waste, which is hard to be treated. In order to resolve this problem, KAERI has been developed a chemical decontamination process using chelate-free inorganic acid, HyBRID (Hydrazine Based Reductive metal Ion Decontamination) process. Especially, the Cyclic SP (Sulfuric acid/Permanganate)- HyBRID process was suggested as the decontamination process for applying to the remove the double oxide layer generated on the reactor coolant system in the pressurized water reactor (PWR). During the Cyclic SP-HyBRID process, the process is continuously applied without discharging or recharging of the decontamination process solution from the primary circuit. Thus, it is necessary to include the removal processes of the decontamination reagents middle of the Cyclic SP-HyBRID process, e.g., ‘Mn removal step’ for removing the permanganate ions and ‘hydrazine decomposition step’ for decomposition of the remaining hydrazine. During these removal processes, the metal ions can also be removed from the process solution. In this study, the behaviors of metals were investigated during the Cyclic SP-HyBRID process. The concentration changes of metal ions in the process solution were analyzed using atomic absorption (AA) spectroscopy. The metal precipitates generated during the process were characterized using X-ray diffraction (XRD) and Fourier Transform Infrared (FT-IR) spectroscopy. From the results of the analysis, it was observed that the metal ions dissolved in the process solution were converted into metal hydroxides and precipitated at the Mn removal process. It was confirmed by equilibrium calculation result that the OH− ions generated at the Mn removal can react with the metal ions and form the metal hydroxides. It is considered that this removal behaviors of the metals can contribute the decontamination performance.
        32.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The clear-water phase (CWP) is a notable limnological phenomenon in freshwater systems caused by predatory interactions between large filter-feeding zooplankton and phytoplankton. However, the mechanisms and factors that influence the extent of CWP, particularly in complex water systems with both fluvial and lacustrine characteristics, remain poorly understood. The present study evaluated CWP occurrence patterns at different sites in a large reservoir located in a temperate monsoon region (Lake Paldang, Korea); the relationships among factors associated with CWP occurrence, such as transparency, zooplankton diversity, and chlorophyll a concentration were investigated. Transparency exhibited significant correlations with precipitation and retention time, as well as the relative abundance of zooplankton (p<0.01), suggesting that a change in the retention time due to precipitation can alter CWP. Data collected before and after CWP occurrence were analyzed using paired t-test to determine variations in CWP occurrence based on the water system characteristics. The results demonstrated that various factors were associated with CWP occurrence in the fluvial-type and lacustrine-type sites. The correlation between zooplankton biomass and transparency was stronger in the lacustrine-type sites than in the fluvial-type sites. The lacustrine-type sites, where cladoceran emergence is common and is associated with long retention times, favored CWP occurrence. The results suggest that lacustrine-type sites, which are conducive to zooplankton development and have relatively long retention times, enhance CWP occurrence. Furthermore, CWP occurrence was notable in spring, and the present study revealed that site-specific CWP could occur throughout the year, regardless of the season.
        4,300원
        33.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A pump-type eDNA filtering system that can control voltage and hydraulic pressure respectively has been developed, and applied a filter case that can filter out without damaging the filter. The filtering performance of the developed system was evaluated by comparing the eDNA concentration with the conventional vacuum-pressured filtering method at the catchment conduit intake reservoir. The developed system was divided into a voltage control (manual pump system) method and a pressure control (automatic pump system) method, and the pressure was measured during filtering and the pressure change of each system was compared. The voltage control method started with 65 [KPa] at the beginning of the filtering, and as the filtering time elapsed, the amount of filtrate accumulated in the filter increased, so the pressure gradually increased. As a result of controlling the pressure control method to maintain a constant pressure according to the designed algorithm, there was a difference in the width of the hydraulic pressure fluctuation during the filtering process according to the feedback time of the hydraulic pressure sensor, and it was confirmed that the pressure was converged to the target pressure. The filtering performance of the developed system was confirmed by measuring the eDNA concentration and comparing the voltage control method and the hydraulic control method with the control group. The voltage control method obtained similar results to the control group, but the hydraulic control method showed lower results than the control group. It is considered that the low eDNA concentration in the hydraulic control method is due to the large pressure deviation during filtering and maintaining a constant pressure during the filtering process. Therefore, rather than maintaining a constant pressure during filtering, it was confirmed that a voltage control method in which the pressure is gradually increased as the filtrate increases with the lapse of filtering time is suitable for collecting eDNA. As a result of comparing the average concentration of eDNA in lentic zone and lotic zone as a control group, it was found to be 96.2 [ng μL-1] and 88.4 [ng μL-1l], respectively. The result of comparing the average concentration of eDNA by the pump method was also high in the lentic zone sample as 90.7 [ng μL-1] and 74.8 [ng μL-1] in the lentic zone and the lotic zone, respectively. The high eDNA concentration in the lentic zone is thought to be due to the influence of microorganisms including the remaining eDNA.
        4,000원
        34.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        계림 환성수계(環城水系)는 중국 계림 자연경관의 중요한 구성 부분이며, 국제적 관광 명소 건설을 위한 계림시의 중요한 공정이자 대외적으로는 계림의 대표적인 관광 브랜드다. 본 연구는 중국 계림 환성수계의 야경 디자인을 평가대상으로 야경 만족도를 평가한 것이다. 설문조사를 바탕으로 탐방객의 관광행태 및 환성수계와 환성수계 야경에 대한 만족도 요인을 살펴보았다. 또한 델파이 조사와 AHP 분석을 통해 확정된 최종 30개 평가지표에 대한 신뢰성과 타당성 분석을 전제로 IPA 분석을 시행하였다. 이 과정에서 Deng(2007)의 방법을 적용하여 성취도 측정항목을 자연로그로 변환한 후 전반적 만족도 변인들의 평균값과 편상관분석치를 상대적 중요도로 한 수정 IPA를 통해 계림 환성수계 야경에 대한 평가를 수행하였다. 전통적 IPA와 수정된 IPA 분석 결과 약간의 차이가 보였는데 특히 1사분면 핵심우세구역과 4사분면 현황유지구역 중 지표 차이가 큰 것으로 나타났다. 중점개선구역인 제2사분면에 있는 조명쇼의 창의적 예술성(C13), 인터랙티브 쇼의 품질(C24), 민속축제의 공연(C28) 등 주로 조명예술의 콘텐츠와 연출 관련된 지표들은 전통적 IPA와 수정된 IPA 분석 결과 모두 관광객의 기대와 중요도는 높지만, 실제 연출력과 만족도가 낮으므로 개선의 여지가 큰 지표들로 향후 우선적으로 개선해야 할 항목으로 부각되었다.
        4,500원
        1 2 3 4 5