        61.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To investigate earthquake responses of structures with basements affected by soil deposits, centrifuge tests were performed using an in-flight earthquake simulator. The test specimen was composed of a single-degree-of-freedom structure model, a basement and sub-soil deposits in a centrifuge container. The test parameters were the dynamic period of the structure model, boundary conditions of the basement, existence of soil deposits, centrifugal acceleration level, and type and level of input earthquake accelerations. When soil deposits did not exist, the earthquake responses of the structures with fixed basement were significantly greater than those of the structure without basement. Also, the earthquake responses of the structures with the fixed basement surrounded by soil deposits were amplified, but the amplifications were smaller than those of the structures without basement. The earthquake responses of the structures with the half-embedded basement in the soil deposits were greater than those estimated by the fixed base model using the measured free-field ground motion. The test showed that the basement and the soil deposit should be simultaneously considered in the numerical analysis model, and the stiffness of the half-embedded was not effective.
        4,300원
        62.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A novel vibration control method for vibration reduction of a spacial structure subjected to earthquake excitation was proposed in this study. Generally, spatial structures have various vibration modes involving high-order modes and their natural frequencies are closely spaced. Therefore, in order to control these modes, a spatially distributed MTMDs (Multiple TMDs) method is proposed previously. MR (Magnetorheological) damper were used to enhance the control performance of the MTMDs. Accordingly, MSTMDs (Multiple Smart TMDs) were proposed in this study. An arch structure was used as an example structure because it has primary characteristics of spatial structures and it is a comparatively simple structure. MSTMDs were applied to the example arch structure and the seismic control performance were evaluated based on the numerical simulation. Fuzzy logic control algorithm (FLC) was used to generate command voltages sent for MSTMSs and the FLC was optimized by genetic algorithm. Based on the analytical results, it has been shown that the MSTMDs effectively decreased the dynamic responses of the arch structure subjected to earthquake loads.
        4,000원
        63.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, shaking table test has been carried out for the dual frame passive control system for seismic performance verification of the proposed system. The proposed system was separated into two independent frameworks that are strength resistant core and frame structure by connecting to the damper. Moreover, the seismic performance improvement of the proposed system has been verified by comparing and analyzing the experimental results of the proposed system with an existing core system. As a result of the shaking table test, acceleration and displacement responses of dual-frame vibration control system are decreased than those of the existing strength resistant type core system. In the case of the core system, while the damage was concentrated on the column of first floor, the damage of the dual system was dispersed in each layer. The damage also was concentrated on the damper, almost no damage occurs to the structural members. It has been emphasized that installed dampers in the proposed dual system reduce the input energy of whole structure by absorbing seismic input energy, which leads overall system damage to be reduced.
        4,000원
        64.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력발전소에는 전력생산과 안전과 관련된 수많은 기기들이 존재하고 있다. 기본적으로 원자력발전소의 구조물과 기기는 지진시 탄성거동올 목표로 안전율을 매우 높게 적용하여 설계해 왔다. 그러나 최근 발생한 지진의 규모가 증가함에 따라 설계수준을 초과한 지진에 대한 기기의 안전성을 재평가할 필요가 있다. 본 연구에서는 구조물의 비선형 거동에 의한 층응답을 분석하였고, 비선형해석에 의한 구조물의 비탄성구조응답계수를 재평가하였다. 기기의 지진취약도 평가시 구조물의 비탄성구조응답이 어떤 영향을 주는지 분석하기 위하여 재평가된 구조물의 비탄성구조응답계수와 기존에 사용되어온 구조물 비탄성구조응답계수를 적용하여 지진취약도 평가를 수행하였다. 해석결과에 따르면 비탄성구조응답계수는 기기의 고유진동수, 기기의 위치 그리고 구조물의 동특성에 따라 영향을 받는 것으로 나타났다.
        4,000원
        65.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A seismic response analysis method for three-dimensional floating offshore structures due to seaquakes is developed. The hydrodynamic pressure exerted on the structure is calculated taking into account the compressibility of the sea water, the fluid-structure interaction, the energy absorption by the seabed, and the energy radiation into infinity. To validate developed method, the hydrodynamic pressure induced by the vibration of a floating massless rigid circular disk is calculated and compared with an exact analytical solution. The developed method is applied to seismic analysis of a support structure for a floating offshore wind turbine subjected to the hydrodynamic pressures induced from a seaquake. Analysis results show that earthquake response of a floating offshore structure can be greatly influenced by the compressibility of fluid, the depth (natural frequencies) of the fluid domain, and the energy absorption capacity of the seabed.
        4,800원
        66.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigate the dynamic response changes of rib dome structure according to property changes of Substructure. Eigenvalue analysis is conducted in first natural frequency of rib dome versus substructure and searched in the dominant mode of horizontal and vertical direction. Resonance frequency by each first natural frequency of the rib dome structure, substructure and total structure is applied for a seismic wave. That is analyzed about maximum displacement response ratio and maximum acceleration response ratio.
        4,000원
        67.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is very important to assure the seismic performance of equipment as well as building structures in seismic design of nuclear power plant(NPP). Seismically isolated structures may be reviewed mainly on the horizontal seismic responses. Considering the equipment installed in the NPP, the vertical earthquake responses of the structure also should be reviewed. This study has investigated the vertical seismic demand of seismically isolated structure by lead rubber bearings(LRBs). For the numerical evaluation of seismic demand of the base isolated NPP, the Korean standard nuclear power plant (APR1400) is modeled as 4 different models, which are supported by LRBs to have 4 different horizontal target periods. Two real earthquake records and artificially generated input motions have been used as inputs for earthquake analyses. For the study, the vertical floor response spectra(FRS) were generated at the major points of the structure. As a results, the vertical seismic responses of horizontally isolated structure have largely increased due to flexibility of elastomeric isolator. The vertical stiffness of the bearings are more carefully considered in the seismic design of the base-isolated NPPs which have the various equipment inside.
        4,200원
        68.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        가스 생산용 해양플랜트 설비의 경우 폭발의 위험에 노출되어 있으며, 폭발사고는 구조물의 안전성에 치명적인 영향을 미칠 수 있다. 따라서, 이러한 폭발사고에 의한 피해를 최소화하기 위해서는, 폭발하중에 의한 구조부재의 동적응답 특성을 명확히 파악할 필요가 있다. 폭발하중의 경우 매우 짧은 시간 동안에 구조물에 가격되었다가 소멸되기 때문에 구조부재의 고유주기 및 폭발하중의 지속시간을 고려한 동적응답 평가가 필수적으로 요구된다. 일반적으로 가스 폭발하중의 경우, 부 압력단계가 전체 하중 이력에서 상당 부분 존재하며, 본 연구에서는 이러한 부 압력단계의 형상에 따라 총 하중 지속시간을 결정하는 하중 모델을 제안하였다. 방화벽은 폭발사고 시 장비 및 인명 피해를 방지하고자 FPSO 탑사이드 모듈 사이에 배치되는 구조부재이므로 폭발하중에 의한 응답이력 특성 분석이 반드시 필요하다. 때문에 무 감쇠 단 자유도 모델에 가스 폭발하중을 적용하여 변위응답 특성을 분석하였으며, 평판으로 구성된 방화벽의 FE 모델을 이용한 하중 지속시간과 구조부재들의 고유주기를 고려한 응답 특성을 분석하였다. LS-DYNA를 이용한 선형/비선형 구조해석 분석결과, 부 압력단계의 지속시간이 구조물의 동적응답에 큰 영향을 주는 것을 보였다.
        4,000원
        69.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        가스 생산용 해양플랜트 설비에서 발생할 수 있는 폭발사고의 경우, 구조 시스템의 기하학적 특성이나, 바람, 가스 누출율 등과 같은 환경적 조건에 의해 피해 규모의 범위가 상당하다. 따라서 폭발파에 의한 구조 부재의 응답을 분석하기 위해서는 이러한 조건들을 고려한 가스폭발 수치해석 과정이 반드시 필요하다. 본 연구에서는 FPSO 탑사이드의 형상 및 장비 배치와 같은 세부적인 부분까지 고려하여 폭발해석을 수행하였으며, 이를 바탕으로 획득한 하중 이력들의 특성을 분석하였다. 또한 다양한 형태로 나타나는 폭발하중 이력들 중 구조물 손상에 직접적으로 영향을 미칠 수 있는 최대 압력과 지속시간들을 고려하여 유한요소해석 시 하중조건으로 적용한 후, 부재의 응답특성에 관한 분석을 수행하였다. 유한요소해석 모델은 실제 구조물에 적용이 가능하고, 복잡한 형상을 이상화한 단 자유도 및 다 자유도 모델을 사용하였다. 정 압력 및 부 압력단계의 최대 압력이 증가함에 따라 구조 부재의 최대 응답이 증가하였고, 부 압단계에서 하중 지속시간이 증가함에 따라 구조물의 최대 변위가 증가는 경향을 보였다.
        4,000원
        70.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the influence of probabilistic variability in stiffness and nonlinearity of soil on response of nuclear power plant (NPP) structure subjected to seismic loads considering the soil-structure interaction (SSI). Both deterministic and probabilistic methods have been employed to evaluate the dynamic responses of the structure. For the deterministic method, SRPmin method given in USNRC SRP 3.7.2(2013) (envelope of responses using three shear modulus profiles of lower bound(GLB), best estimate(GBE) and upper bound(GUB)) and SRPmax method (envelope of responses by more than three ground profiles within range of GLB≤G≤GUB) have been considered. The probabilistic method uses the Latin Hypercube Sampling (LHS) that can capture probabilistic feature of soil stiffness defined by the median and the standard deviation. These analysis results indicated that 1) number of samples shall be larger than 60 to apply the probabilistic approach in SSI analysis and 2) in-structure response spectra using equivalent linear soil profiles considering the nonlinear behavior of soil medium can be larger than those based on low-strain soil profiles.
        4,300원
        71.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In military, Electro-optic/Infra-red system that is used to obtain the target image of high performance induced blur images by the vibration of the carrier and inner optical devices. Optical devices of the EO/IR is constituted by the optical lens, detector and mechanical assembly. High performance detectors for IR camera are typically used for stirling cryocooler to maintain the temperature of the detection surface cryogenically. However, This cooler induces a blur image on detector surface by the vibration. In this study, we performed modal analysis and response analysis of the mounting structure design which can minimize the vibration of the cooler and detector. Also, We confirmed that we were designed robust mounting structure according to the vibration through the response analysis models the inner gimbal and optics.
        4,000원
        72.
        2015.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.
        4,200원
        73.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        LNG 방열 시스템의 선형 동적해석 모델을 사용하여 슬로싱 충격 압력을 구조해석에 적용 시 사용되는 이상화된 삼각파 압력에 대해서 검토하였다. 삼각파 압력의 최대값, 지속시간, 비대칭성의 충격파에 대한 구조 안전성 평가를 위해서 멤브레인 구조의 허용기준과 슬로싱 압력에 관련된 간략화된 파괴압력에 대해 검토하고, 슬로싱 충격 압력의 지속시간과 비대칭성으로 특징 지워진 이상화된 삼각파 형상의 압력을 고려한 일련의 선형 동적해석을 수행하여 설계기준으로 사용할 파괴압력을 도출하였다. 본 논문에서 제시한 방법을 통해서 방열시스템 구조 요소의 안전성을 평가하기 위한 파괴 압력을 선정할 수 있고 모형실험을 통한 슬로싱 압력과의 비교를 통하여 방열시스템의 구조안전성을 평가할 수 있을 것이라 판단된다. 또한 해석결과를 통해 방열시스템에서의 최대 응력은 매우 짧은 순간의 충격하중 하에서는 압력의 비대칭성 보다는 하중 지속시간에 많은 영향을 받고 있음을 검토하였다.
        4,000원
        74.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 질점계 비선형 지진응답해석을 통한 역량스펙트럼 도출방법을 소개한다. 일반적인 건축물의 손상도 평가는 비선형 등가정적해석(Push-over Analysis)을 통하여 건축물의 역량스펙트럼을 도출하고, 역량스펙트럼과 요구스펙트럼의 교차점을 성능점으로 평가하고 있다. 등가정적해석은 지진의 영향을 등가의 정적하중으로 환산한 후 이를 이용하여 정적해석을 수행함으로써 구조물의 지진에 의한 거동을 예측하는 방법이다. 이 방법은 고차모드 및 층별 동특성의 영향을 고려할 수 없다. 따라서 건축물의 동특성이 반영된 역량스펙트럼을 산출하기 위하여 질점계 비선형 지진응답해석을 진행하여 건축물의 역량 스펙트럼을 제안하고자 한다.
        4,000원
        75.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Spatial structures as like dome structure have the different dynamic characteristics from general rahmen structures. Therefore, it is necessary to accurately analyze dynamic characteristics and effectively control of seismic response of spatial structure subjected to multi-supported excitation. In this study, star dome structure that is subjected to multi-supported excitation was used as an example spatial structure. The response of the star dome structure under multiple support excitation are analyzed by means of the pseudo excitation method. Pseudo excitation method shows that the structural response is divided into two parts, ground displacement and structural dynamic response due to ground motion excitation. And the application of passive tuned mass damper(TMD) to seismic response control of star dome structures has been investigated. From this numerical analysis, it is shown that the seismic response of spatial structure under multiple support seismic excitation are different from those of spatial structure under unique excitation. And it is reasonable to install TMD to the dominant points of each mode. And it is found that the passive TMD could effectively reduce the seismic responses of dome structure subjected to multi-supported excitation.
        4,000원
        76.
        2014.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Considering a rigorously fluid-structure interaction, a method for an earthquake response analysis of a floating offshore structure subjected to vertical ground motion from a seaquake is developed. Mass, damping, stiffness, and hydrostatic stiffness matrices of the floating offshore structure are obtained from a finite-element model. The sea water is assumed to be a compressible, nonviscous, ideal fluid. Hydrodynamic pressure, which is applied to the structure, from the sea water is assessed using its finite elements and transmitting boundary. Considering the fluid-structure interaction, added mass and force from the hydrodynamic pressure is obtained, which will be combined with the numerical model for the structure. Hydrodynamic pressure in a free field subjected to vertical ground motion and due to harmonic vibration of a floating massless rigid circular plate are calculated and compared with analytical solutions for verification. Using the developed method, the earthquake responses of a floating offshore structure subjected to a vertical ground motion from the seaquake is obtained. It is concluded that the earthquake responses of a floating offshore structure to vertical ground motion is severely influenced by the compressibility of sea water.
        4,200원
        77.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 철근콘크리트 구조물의 지진해석에 관한 국제 벤치마크 프로젝트인 SMART-2013을 통해 3차원 비대칭 철근콘크리트 건물의 고유진동수와 재료 비선형성을 고려한 지진응답을 계산한 결과를 제시한다. 이를 위해 콘크리트와 철근의 비선형 재료모델을 구성하고 대표부피요소에 대한 국부테스트를 수행하여 비선형 모델의 성능을 평가하였다. 이러한 SMART-2013 철근콘크리트 건물의 비선형 유한요소모델에 대해 모드해석과 저강도 지진하중에 대한 선형 시간이력해석을 수행한 결과, 구조물의 고유진동수, 변위 및 가속도 시간이력이 SMART-2013 프로젝트에서 제시한 실험값들과 유사하였다. 또한 Northridge 지진에 대한 변위 및 가속도 응답의 시간이력과 최대층간상대변위의 응답스펙트럼을 계산하여 고강도 지진 하중에 대한 이 철근콘크리트 건물의 거동을 평가하였다.
        4,000원
        78.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        면진장치는 지진력을 감소시키기 위하여 사용되어왔다. 원자력발전소에 면진장치가 적용된다면, 운영기간동안 구조물과 기기들은 동일한 내구성 및 성능이 확보되어야 한다. 본 연구에서는 면진된 원전의 지진에 대한 안전성을 확보하기 위하여 면진구조물의 장기거동을 해석적으로 분석하였다. 경년열화에 의한 면진장치 특성을 분석하였고, 다른 온도환경에서 면진장치의 경년열화에 의한 구조물의 지진응답을 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 면진구조물의 고유진동수는 증가하였다. 그러나 면진 구조물의 최대가속도와 최대변위는 온도에 따라 크게 변하지 않았다. 면진장치의 열화에 의하여 구조물의 손상은 발생하지 않았지만 목표진동수 영역에서 스펙트럼가속도는 온도에 따라 증가하였다. 따라서 면진구조물에서 면진장치는 온도에 따른 지진응답의 증가를 고려하여 설치 및 제작해야 할 것으로 판단된다.
        4,000원
        80.
        2014.04 구독 인증기관·개인회원 무료
        Risers are often exposed to harsh ocean environments, and vulnerable to various damages. The riser failure may cause serious economical losses as well as environmental problems. Therefore, maintaining the structural integrity of the riser is very important. This paper deals with the methodology for monitoring structural integrity of the riser using dynamic characteristic changes such as mode shapes. The damage index method, which has been proved its usefulness in many applications, is applied to a numerical study to test its feasibility of identifying damage in a riser. The numerical study is performed using OcraFlex 9.4, specialized program for analyzing marine structures. The numerical study shows that the damage index method can identify damage in the riser.