        82.
        2014.10 서비스 종료(열람 제한)
        Durability and structural safety of steel structure are severely affected by corrosion caused by deicer material as well as by airborne chlorides in the marine environment. In this study, based on analysis of current status it is suggested that deterioration and durability reduction by the environmental factor such as chlorides should be more reasonably taken into consideration for the accurate inspection and condition evaluation of steel structures.
        86.
        2013.11 KCI 등재 서비스 종료(열람 제한)
        비파괴 기법중 반전위 측정법은 부식가능성을 정량적으로 판별할 수 있으므로 꾸준하게 사용되고 있다. 본 연구에서는 피복두께를 10, 30, 60mm, 물-시멘트비를 0.35, 0.55, 0.70으로 변화시킨 RC 시편을 대상으로 비말대 지역을 모사한 촉진염해분무실험을 수행하였다. 45일간의 촉진 염해 분무시험을 수행한 뒤, RC 시편에 대하여 반전위값을 측정하였다. w/c 0.55 조건에서 피복두께가 10mm인 RC 시편은부식이 발생하였으며, w/c 0.7인 경우 피복두께 30mm인 시편에서도 부식이 발생하였다. 실험결과를 이용하여 물-시멘트비와 피복두께를 변수로 하는 반전위 평가식을 제안하였으며, 비말대지역에서 부식을 억제할 수 있는 조건을 도출하였다. 또한 Life 365 프로그램을 이용하여 비부식 조건의 w/c와 피복두께를 분석하였으며, 본 연구의 결과인 반전위 측정값과 비교하였다.
        87.
        2013.10 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the corrosion protection properties of Zn/Sn metal spray method according to the contents ratio of Zn and Sn by CASS test. Also, the corrosion protection life of Zn/Sn metal spray method is evaluated by the comparing between the corrosion properties of Zn metalizing method and Zn/Sn metal spray method using CASS test. As a result, it was confirmed that the optimum content ratio of Zn/Sn in metal spray method is 60:40(65:35) (Zn : Sn volume ratio) in aspect of corrosion protection properties and construction properties. Also, it was confirmed that the Zn/Sn metal spray method had more than 3 times of corrosion protection properties cmparing the Zn matalizing method.
        88.
        2013.10 서비스 종료(열람 제한)
        The corrosion is a main cause of degradation damage in the steel bridges. The evaluation whether the repair or reconstruction would be need or not for the corroded steel member, is based on cross section and quantity of corroded portion. It is considered reasonable that the evaluation will be base on the endurance of the corroded member. In this study, the bending endurance of the I-shaped steel girder with the local corrosion on the lower flange is discussed by using elastic-plastic finite element analyses. That simple way of estimating it is also proposed.
        89.
        2013.04 서비스 종료(열람 제한)
        To assess the steel corrosion resistance for Calcium aluminate cement and Ordinary portland cement against internal chloride ions, mortar specimens were cast, assuming aggregates are inert. Linear polarisation, half-cell potential and mass loss were chosen to measure the rate of steel corrosion.
        90.
        2013.04 서비스 종료(열람 제한)
        Marine bridges are deteriorated due to the exposure under marine environment. The structure deterioration occurred by corrosion of steel in concrete is mainly relevant to chloride in seawater. The cathodic protection technique is an unique measurement to stop the corrosion of steel. In this study, the detail maintenance strategy of cathodic protection system in KEC's experience is introduced.
        91.
        2013.04 서비스 종료(열람 제한)
        The durability of structures that has been built along the coastline based on the national geographic characteristics became a very important standard in economic and societal aspects. The environment that the steel corrosion would most likely happen is called tidal zone. It is a well-known zone and lots of researches have been done. We decided to implement steel corrosion monitoring on artificial seawater to find what kind of environment accelerates the steel corrosion. We compared and analyzed the experiment through galvanic potential measurement and half cell potential measurement
        92.
        2012.03 KCI 등재 서비스 종료(열람 제한)
        콘크리트내의 철근의 부식은 열화와 콘크리트 구조물의 조기파괴의 주된 원인이 된다. 본 연구에서는 비파괴 기법 중 전자기적 열유도방법과 적외선 열화상기법을 이용한 철근부식평가가 시도되었는데, 부식 또는 비부식된 철근의 열특성 차이를 이용한 것이다. 본 논문은 이러한 개념을 배경으로 수행한 실험적 연구이며, 유도전류를 통해 콘크리트 표면으로부터 내부 철근을 가열하고 외부의 적외선 카메라를 이용하여 표면의 온도변화를 관측한다. 피복두께가 다른 콘크리트 시편은 앞면과 배면의 피복두께를 동일하게 제조하여 앞면에서 가열과 배면에서의 온도측정을 동시에 할 수 있도록 고안되었다. IC (Impressed Current) 방법을 통하여, 철근 부식을 촉진하였으며, 적외선 화상을 통하여 온도가열과 냉각을 전 시험과정에 걸쳐 측정하였다. 본 실험을 통하여 부식/비부식 철근의 뚜렷한 온도변화를 확인하였으며, 부식된 시편에서 빠른 온도증가속도 및 냉각속도를 평가하였다. 본 연구는 콘크리트 매립철근의 비파괴적인 부식탐지의 가능성을 보여주고 있다.
        93.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        시멘트 대체 재료로서 플라이애쉬의 사용은 시멘트 생산비용을 절감시키는 효과를 창출하였다. 반면에 플라이애쉬 혼입콘크리트는 OPC에 비해 상대적으로 긴 양생시간과 초기강도의 발현 저하를 들 수 있어 이의 해결을 위해 물리적 방법, 온도 및 화학적 방법 등과 같은 다양한 활성화 기술의 적용을 통하여 플라이애쉬 혼입 콘크리트의 수화를 가속시킬 수 있고, 콘크리트의 부식 저항성을 향상시킬 수가 있다. 본 연구에서는 10~40%의 치환률을 가진 활성화된 플라이애쉬 시편을 통해 개방 회로형 전위측정(Open circuit potential measurement)을 수행하였고, 투수시험, 급속염화물침투시험 및 SEM(Scanning electron microscopy)촬영을 통해 OPC 콘크리트와 비교․분석 하였다. 또한, 치환률의 임계범위 20~30%의 경우에 있어서 활성화된 플라이애쉬를 사용한 콘크리트가 열화저항성에 있어서 개선효과가 나타나고 있음을 확인하였다. 또한 플라이애쉬를 화학적으로 활성화시킨 경우가 본 연구에서 수행된 다른 활성화 방법들에 비해 더욱 좋은 결과를 나타나고 있음도 확인하였다.
        94.
        2005.01 KCI 등재 서비스 종료(열람 제한)
        Because of the toxicity of hexavelant chromium ion, treatments of metallic surface with chromate compounds to retard corrosion are undesirable for safety control in industrial uses and protection of environment. In this study, we investigated several compounds such as inorganic, organic, and polymer materials in order to substitute the chromate conversion treatment on steel sheet. The corrosion property was investigated in a salt spray tester with 3.5 wt.% NaCl at 35℃. The results showed that the zirconium/silane/polymer triple coatings on the galvanized steel exhibited a significant retardation of corrosion. Although the multicoating system needs a complexed processing, we can confirm a possibility of development of a chromate-free chemical conversion treatment for galvanized steel sheet.