검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 55

        2.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete frame buildings designed for only gravity loads have been seismically vulnerable due to their inadequate column detailing. The seismic vulnerabilities can be mitigated by the application of a column retrofit technique, which combines high-strength near surface mounted bars with a fiber reinforced polymer wrapping system. This study presents the full-scale shaker testing of a non-ductile frame structure retrofitted using the combined retrofit system. The full-scale dynamic testing was performed to measure realistic dynamic responses and to investigate the effectiveness of the retrofit system through the comparison of the measured responses between as-built and retrofitted test frames. Experimental results demonstrated that the retrofit system reduced the dynamic responses without any significant damage on the columns because it improved flexural, shear and lap-splice resisting capacities. In addition, the retrofit system contributed to changing a damage mechanism from a soft-story mechanism (column-sidesway mechanism) to a mixed-damage mechanism, which was commonly found in reinforced concrete buildings with strong-column weak-beam system.
        4,300원
        3.
        2018.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This study deals with the microstructure and tensile properties of 700 MPa-grade high-strength and seismic reinforced steel bars. The high-strength reinforced steel bars (600 D13, 600 D16 and 700 D13 specimens) are fabricated by a TempCore process, while the seismic reinforced steel bar (600S D16 specimen) is fabricated by air cooling after hot rolling. For specimens fabricated by the TempCore process, the 600 D13 and 600 D16 specimens have a microstructure of tempered martensite in the surface region and ferrite-pearlite in the center region, while the 700 D13 specimen has a microstructure of tempered martensite in the surface region and bainite in the center region. Therefore, their hardness is the highest in the surface region and shows a tendency to decrease from the surface region to the center region because tempered martensite has a higher hardness than ferrite-pearlite or bainite. However, the hardness of the 600S D16 specimen, which is composed of fully ferritepearlite, increases from the surface region to the center region because the pearlite volume fraction increases from the surface region to the center region. On the other hand, the tensile test results indicate that only the 700 D13 specimen with a higher carbon content exhibits continuous yielding behavior due to the formation of bainite in the center region. The 600S D16 specimen has the highest tensile-to-yield ratio because the presence of ferrite-pearlite and precipitates caused by vanadium addition largely enhances work hardening.
        4,000원
        4.
        2017.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This present study deals with the microstructure and tensile properties of 600 MPa-grade high strength and seismic resistant reinforcing steels. The high strength reinforcing steel (SD 600) was fabricated by Tempcore processing, while the seismic resistant reinforcing steel (SD 600S) was air-cooled after hot-rolling treatment. The microstructure analysis results showed that the SD 600 steel specimen consisted of a tempered martensite and ferrite-pearlite structure after Tempcore processing, while the SD 600S steel specimen had a fully ferrite-pearlite structure. The room-temperature tensile test results indicate that, because of the enhanced solid solution and precipitation strengthening caused by relatively higher contents of C, Mn, Si and V in the SD 600S steel specimen, this specimen, with fully ferrite-pearlite structure, had yield and tensile strengths higher than those of the SD 600 specimen. On the other hand, the hardness of the SD 600 and SD 600S steel specimens changed in different ways according to location, dependent on the microstructure, ferrite grain size, and volume fraction.
        4,000원
        5.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.
        4,000원
        6.
        2013.09 구독 인증기관 무료, 개인회원 유료
        In this study, Rebar of SD500, SD600 is applied to the designed or constructed in domestic apartment. Analyzed the variation of the rebar according to the strength of the rebar and the construction cost of the change. Reinforced volume reduction of the apartment building is less than the other. Because, A low wall of rebar reduction is more than 50% of the total. The reason for the previous, Reduction of the quantity of horizontal reinforcement does not appear and Vertical rebar reinforcement than the stress is determined by the placement of rebar in which the upper floor.
        4,000원
        7.
        2013.03 구독 인증기관 무료, 개인회원 유료
        In this study, Rebar of SD500, SD600 is applied to the designed or constructed in domestic underground parking. Analyzed the variation of the rebar according to the strength of the rebar and the construction cost of the change. Most of underground parking appear reduction of Rebar ratio. In this case, the load acting on the underground parking garage is large. So, Rebar placing is dominated by element's stress. Therefore, Large amounts material of slabs, beams and foundations are reduced. In case of columns and wall, Ratio of Material reduction is less than former. Because Splice and Anchorage of rebar amounts are increased and Hoop and horizontal rebar amounts are fixed. Percentage of rebar of the column and wall are 15%. So, Showed a less impact on the reduction of total material.
        4,000원
        8.
        2012.09 구독 인증기관 무료, 개인회원 유료
        Strength bar has merits in workability improvement, construction time shortening and connection details to be easy. But, lap splice length tends to be longer. In this study, high strength threaded bar will be reviewed whether it is appropriate in domestic standards by KCI concrete structural criteria and propose the mechanical splice.
        4,000원
        9.
        2010.09 구독 인증기관 무료, 개인회원 유료
        Recently, practical application of high tension bar is attempted. The main object of using high tension bar is strengthening of material property and decreasing of steel amount. If using high tension bar which is not a definite yield strength,according to strain ratio of high tension bar tensile and compressive dominate mode ciearly, there being a possibility dividing becoming difficult. Specially, Providing steel ratio of balanced destruction is very difficult. In this study, high tension bar to apply to flexural member and the behavior experiment bending after one, will consider high tension bar the application possible standard of existing.
        4,000원
        10.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고강도 재료(고강도 콘크리트, 고강도 철근)가 사용된 철근콘크리트 부재의 전단파괴모드는 보통강도 재료를 사용한 부재의 전단파괴모드와 상이한 결과를 나타낼 수 있다. 고강도 재료가 사용될 경우에 구조설계기준식에서 요구하는 전단보강철근이 먼저 항복한 후에 콘크리트가 압축파괴하는 것과는 다르게, 철근이 항복하기 이전에 콘크리트가 압축파괴할 수 있다. 이 논문에서는 고강도 재료가 사용된 철근콘크리트 부재의 최대철근비를 균형파괴시의 재료의 응력 및 변형률 상태를 이용하여 계산하였다. 제안식에서 최대철근비는 콘크리트의 압축강도와 전단보강철근의 상호관계에 의하여 변화하였다. 제안식은 97개의 철근콘크리트 부재에 대한 실험결과와 비교되었다. 실험결과 및 계산결과는 철근콘크리트 부재의 파괴모드가 전단보강철근의 양과 콘크리트의 압축강도와 밀접한 관계가 있음을 나타내었다.
        4,000원
        11.
        2006.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구의 목적은 고강도 철근콘크리트 교각의 비탄성 거동을 파악하는데 있다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 PCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열모델로서는 분산 균열모델을 사용하였다. 횡방향 구속철근으로 구속된 고강도 콘크리트의 강도 증가 효과를 고려하였다. 이 연구에서는 고강도 철근콘크리트 교각의 비탄성 거동의 파악을 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.
        4,000원
        12.
        2005.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건축 구조물이 초고층화, 대형화, 특수화 되어감에 따라 고강도 재료의 사용이 증대되고 있으며, 고강도 재료가 사용된 철근콘크리트 보의 전단강도를 타당하게 예측할 수 있는 해석모델이 반드시 필요하다. 본 연구에서는 고강도 철근이 사용된 철근콘크리트 보의 전단강도를 타당하게 예측할 수 있는 트러스 모델을 제안한다. 고강도 철근이 사용된 철근콘크리트 보의 전단강도에 대한 제안된 모델인 TATM의 타당성을 검토하기 위하여 총 107개 보의 실험결과를 수집하였으며, TATM 및 기존 트러스 모델의 전단강도 해석결과를 이들 실험결과와 비교하였다. 비교 결과, TATM은 다른 트러스 모델보다 실험결과를 더 잘 예측하였으며, TATM의 해석결과에 대한 실험결과의 비는 인장철근과 전단 철근의 항복강도에 거의 관계없이 일정하였다.
        4,000원
        13.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        본 논문은 강섬유 보강 콘크리트 부재에 수직으로 기계적 정착된 고강도 확대머리철근의 정착성능을 평가하기 위하여 실시한 기초 인발실험결과를 정리한 것이다. 주요 실험변수는 강섬유의 혼입률, 콘크리트 강도, 정착길이, 확대머리철근 항복강도 , 전단보강유무 등이다. 실험체의 좌우 순피복두께는 확대머리철근 직경의 두 배로 계획하였다. 확대머리철근을 중심으로 1.5ldt,0.7ldt가 되는 위치에 힌지 지점을 두고, 확대머리 철근을 직접 인발하였다. 인발실험결과, 실험변수에 따라 콘크리트 파괴 및 철근 인장파단이 나타났다. 강섬유를 보강한 실험체가 동일한 변수의 강섬유를 보강하지 않은 실험체에 비히여 콘크리트 압축강도는 2.7~5.4% 크게 나타난 반면 인발강도는 20.9~63.1% 크게 나타나 정착성능 향상에 큰 기여를 하는 것으로 평가되었다. 강섬유 보강 콘크리트에 대해 확대머리철근과 평행한 전단보강근의 배근은 1.7~7.7% 인발강도를 증가시켰으나, 콘크리트 강도 증가를 고려할 때 정착성능 향상에 미치는 영향이 크지 않았다. 본 실험체 상세와 같이 강섬유보강 콘크리트 부재에 수직정착된 SD600의 확대머리철근 정착설계는 KCI2017, KCI2012의 정착길이 설계식을 그대로 사용할 수 있을 것 으로 사료된다.
        14.
        2019.10 서비스 종료(열람 제한)
        최근 지진의 발생 빈도가 잦아지면서 고강도 내진 철근에 대한 관심이 급증하였다. 그러나 현재 콘크리트구조 학회기준 (2017)에서는 철근콘크리트 부재의 전단철근의 항복강도를 500MPa로 제한하고 있다. 이 논문에서는 이러한 설계기준항복강도 제한을 확장하기 위해 고강도 내진 철근을 사용한 철근콘크리트 보의 실험을 수행하였다. 실험에는 항복강도가 400MPa, 500MPa, 700MPa인 전단철근이 사용되었으며 전단철근의 배근간격을 변수로 하여 철근비에 따른 철근콘크리트 보의 전단거동을 비교하였다. 실험결과 철근량과 철근의 항복강도가 증가할수록 전단강도비가 감소하는 경향이 나타났다.
        15.
        2019.09 KCI 등재 서비스 종료(열람 제한)
        확대머리 SD600 고강도 인장철근으로 단부 정착된 SFRC 깊은보의 전단성능을 평가하기 위해 전단 실험을 수행하였다. 실험 변수는 주인장 철근의 단부 정착방법(확대머리 철근, 일자형 철근), 단부 정착길이, 전단보강근 유무 등이다. 전단경간비는 1을 가지는 실험체에 대한 전단실험결과, 모든 실험체는 초기 휨 균열이 발생한 후 경사균열이 진행되면서 최종적으로 압축전단파괴되었다. 확대머리 철근으로 기계적 정착된 실험체들이 일자형 철근 정착에 비하여 5.6∼22.4% 더 큰 전단강도를 나타내었다. 확대머리 철근으로 기계적 정착된 실험체들에 대하여 최대하중의 75%까지는 지압응력이 전체 정착응력의 0.9~17.2%에 도달하였으나, 최대하중 시점에서 지압응력이 전체 정착응력의 22.4%~46%에 도달하여 큰 응력 부담률을 나타내었다. 이를 통하여 확대머리 지압응력에 의한 정착응력 증가가 전단강도에 큰 영향을 미침을 알 수 있다. 실험 전단강도가 실용식에 의한 전단강도의 2.68~4.65 배로 평가되어, 실용식이 전단내력을 안전측으로 평가하였다.
        16.
        2019.04 서비스 종료(열람 제한)
        In this paper, anchorage behavior of high-strength headed rebar with minimum edge distance was evaluated. The experimental parameters are the compressive strengths of concrete, the strengths and the anchorage lengths of headed rebar. The maximum pullout strengths and final failure modes were evaluated through the experiment.
        17.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        본 연구는 순환골재를 사용한 콘크리트의 활용증대 방안으로 철근콘크리트 구조물의 노후화와 내구성 저하 시 보수․보강으로 사용되는 FRP (AFRP, CFRP) 판으로 보강된 순환골재 고강도콘크리트(40MPa, 60MPa) 보를 제작하여 순환골재 철근콘크리트 보의 휨 보강에 대한 적용성을 평가하고자 한다 기존의 표면매입보강에 따른 에폭시와 FRP 판의 부착력을 고려하지 않기 위해 콘크리트 타설 전 FRP 보강판을 거푸집에 미리 설치하였으며, 순환골재 치환율(30%), 콘크리트 강도(40MPa, 60MPa), 이형철근(D10, D13), FRP 판의 종류(AFRP 판, CFRP 판)를 변수로 12개 실험체를 제작하여, FRP 판과 순환골재 치환율에 따른 휨 성능을 분석하였다. 그 결과 FRP 판으로 보강한 실험체는 무보강 실험체에 비해 최대 17% 증가하는 경향을 나타내었으며 AFRP 판에 비해 CFRP 판의 보강 성능이 우수한 것으로 나타났다. 또한 순환골재 치환율에 따른 보강 성능의 차이는 없는 것으로 나타났다. 실험에 의해 측정된 균열모멘트는 파괴계수를 이용한 결과 기준식과 비슷한 값을 나타났으며 휨 모멘트는 FRP 판을 보강한 일부 시험체가 KCI 2012와 ACI 440-2R에서 제시한 기준을 만족하지 못하는 것으로 나타났다.
        18.
        2018.04 서비스 종료(열람 제한)
        In this paper, the shear performance of the deep beams with high strength headed reinforcement was evaluated. The experimental parameters are high strength headed bar a gunboat. The shear span-depth ratio (a/d) of specimens was 1. The development length of headed reinforcement was evaluated to have a great influence on the shear strength of the deep beam.
        19.
        2018.04 서비스 종료(열람 제한)
        The purpose of this study is to investigate the effects of reinforcement arrangements on the high strength of concrete and to present the quantitative values. To complete this research, two types of concrete strengths (40 MPa and 60 MPa), two types of reinforcing bar diameters (10 ㎜ and 13 ㎜), and seven types of specimens with or without reinforcement arrangements were prepared and tested for compressive strength. As a result, the strength of the cores containing the reinforcement can be predicted to have 82% - 94% of the strength of the cores without reinforcement.
        20.
        2018.01 KCI 등재 서비스 종료(열람 제한)
        초고층 및 장경간 등 대형 구조물에 대한 시공시 부재의 품질이 저하될 정도로 과다한 철근이 배근되고 있다는 문제점이 제기되고 있으며, 최근 건축되고 있는 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용 재료의 강도도 점차 증가하고 있다. 초고층 및 장경간 구조물의 시공에서 고강도 철근을 사용할 경우 기존의 일반 강도 철근에 비해 배근량 감소로 인하여 부재에서 배근 간격에도 여유를 줄 수 있어 시공성 향상, 공기단축, 접합부 상세가 간소화 되는 장점이 있다. 이 연구에서는 SD500, SD600 철근을 국내에서 설계되었거나 시공되 어진 라멘 구조 형식의 지하주차장 건축물에 적용하여 각 부재별로 철근의 강도에 따른 순수 철근량에 대한 정착 및 이음 철근량 증감을 비교 분석한 결과 다음과 같은 결론을 얻었다. 계산된 철근의 정착 및 이음 물량은 사용철근의 강도가 증가함에 따른 정착 및 이음길이의 증가량과 순수 물량의 감소비율, 사용철근의 직경이 줄였을 때의 단면적 감소 등의 요인들에 의해 정착 및 이음 물량이 결정되었으며, 전체적으로 순수 물량에 대한 정착 및 이음 물량의 비율이 SD400대비 SD500의 경우는 증가하였지만 SD500대비 SD600의 경우는 감소하였다. 이는 보의 정착 및 이음 물량이 전체 정착 및 이음 물량에 미치는 영향이 크기 때문으로 판단된다. 한편 순수 물량에 대한 정착 및 이음 물량의 비율에서 SD400 과 SD500의 차이와 SD400과 SD600의 차이가 미미하여 철근의 정착 및 이음 물량이 강도 증가에 따른 전체 철근 물량의 증감에는 큰 영향을 주지 않는 것으로 파악되었다.
        1 2 3