국내에서 지진 발생빈도가 증가함에 따라 다가구주택 필로티기둥의 내진보강이 필수적이다. FRP 패널은 경량성과 고강도를 갖춘 내진 보강재료 사용되고 있으나, 상대적으로 낮은 임계온도로 인해 화재에 취약하다. 따라서 FRP 패널로 보강된 RC 기둥의 내화 성능을 확보할 방안이 필요하다. 본 연구에서는 FRP 패널로 보강된 RC 기둥의 내화성능을 평가하기 위해, FRP 패널의 열적특성(비열, 열전도율, Weight loss)을 확인하는 소재시험을 진행하였다. 또한, FRP 패널로 보강된 RC 단주기둥에 뿜칠을 도포하고, 표준화재 1시간 동안의 온도거동을 분석하였다.
Tunnel fires have significant social and economic impacts, causing extensive damage to concrete and steel reinforcements at high temperatures. Despite international advancements in fire-resistant designs, the safety measures for tunnel fires in South Korea remain insufficient. This study aimed to evaluate the fire resistance of fiber-reinforced concrete incorporating fire-resistant fibers with a focus on preventing spalling and enhancing structural safety. These findings are expected to contribute to the development of fire-resistant tunnel-design standards. Concrete mixtures with compressive strengths of 27 MPa were prepared according to highway construction material standards. Fiberreinforced concrete samples were produced with fire-resistant fiber dosages of 0.0, 0.6, 0.8, and 1.0 kg per cubic meter. Fresh concrete tests, including air content (KS F 2421) and slump (KS F 2402) tests, were conducted along with compressive strength tests (KS F 2405) on the hardened concrete. The fire resistance was assessed using an electric furnace to simulate the fire curve conditions specified in the Road Tunnel Fire Safety Guidelines based on KS F 2257. Increasing the fiber content led to a slight reduction in slump, likely owing to fiber agglomeration, with minimal effect on workability within the tested range. The air content exhibited negligible variation, indicating that there was no major impact on the air-void system. The compressive strength before the fire resistance test fluctuated but consistently met the design target of 27 MPa. The compressive strength after the fire resistance test across all samples decreased to approximately 2.0 MPa. The fiber-reinforced concrete exhibited reduced internal temperatures compared to the control, which was attributed to heat transfer disruption and the formation of micropores by the fibers. In this study, fiber-reinforced concrete demonstrated improved thermal resistance under fire conditions with minimal impact on the workability and air content within the tested range. Although the compressive strength before the fire resistance test remained adequate, the sharp decline in the post-fire strength highlights the need for further optimization. These findings emphasize the potential of fiber-reinforced concrete as a cost-effective solution for enhancing tunnel fire resistance, thereby supporting the development of safer and more resilient infrastructures.
건축물은 사용자의 부주의, 전기적, 기계적 요인 등에 의해 화재가 발생할 수 있고, 화재 발생 시 각 재료의 특성에 따라 강성 및 강도가 감소하여 구조 성능이 저하될 수 있다. 이러한 상황에서 적절 한 성능 복구가 되지 않으면 후에 지진 등의 큰 하중이 가해질 때 건축물 붕괴 등 치명적인 피해가 발생할 수 있다. 현재 내화성능을 높이는 방법으로 내화피복을 사용하는 등 수동적인 방법에 머물러 있으며, 꾸준한 유지관리 등이 필요하다는 단점이 있다. 따라서 변형 후 열을 가하면 원래의 형상으로 돌아가는 성질을 가진 형상기억합금을 사용하여 콘크리트 보를 보강하고, 화재 시, 화재 후에 프리스 트레스트 콘크리트와 유사한 방식으로 콘크리트에 압축응력을 발생시켜 구조 성능을 향상시킬 수 있 는지 ANSYS 구조해석 프로그램을 통해 그 효과를 확인해보고자 한다.
High-entropy alloys (HEAs) are characterized by having five or more main elements and forming simple solids without forming intermetallic compounds, owing to the high entropy effect. HEAs with these characteristics are being researched as structural materials for extreme environments. Conventional refractory alloys have excellent hightemperature strength and stability; however, problems occur when they are used extensively in a high-temperature environment, leading to reduced fatigue properties due to oxidation or a limited service life. In contrast, refractory entropy alloys, which provide refractory properties to entropy alloys, can address these issues and improve the hightemperature stability of the alloy through phase control when designed based on existing refractory alloy elements. Refractory high-entropy alloys require sufficient milling time while in the process of mechanical alloying because of the brittleness of the added elements. Consequently, the high-energy milling process must be optimized because of the possibility of contamination of the alloyed powder during prolonged milling. In this study, we investigated the hightemperature oxidation behavior of refractory high-entropy alloys while optimizing the milling time.
PURPOSES : This study provides fundamental information on the temperature variations in tunnel structures during severe fire events. A fire event in a tunnel can drastically increase the internal temperature, which can significantly affect its structural safety. METHODS : Numerical simulations that consider various fire conditions are more efficient than experimental tests. The fire dynamic simulator (FDS) software, based on computational fluid dynamics (CFD) and developed by the National Institute of Standards and Technology, was used for the simulations. The variables included single and multiple accidents involving heavy goods vehicles carrying 27,000 liters of diesel fuel. Additionally, the concrete material characteristics of heat conductivity and specific heat were included in the analysis. The temperatures of concrete were investigated at various locations, surfaces, and inside the concrete at different depths. The obtained temperatures were verified to determine whether they reached the limits provided by the Fire Resistance Design for Road Tunnel (MOLIT 2021). RESULTS : For a fire caused by 27,000 liters of diesel, the fire intensity, expressed as the heat release rate, was approximately 160 MW. The increase in the carrying capacity of the fire source did not significantly affect the fire intensity; however, it affected the duration of the fire. The maximum temperature of concrete surface in the tunnel was approximately 1400 ℃ at some distance away in a longitudinal direction from the location of fire (not directly above). The temperature inside the concrete was successfully analyzed using FDS. The temperature inside the concrete decreased as the conductivity decreased and the specific heat increased. According to the Fire Resistance Design for Road Tunnel (MOLIT 2021), the internal temperatures should be within 380 ℃ and 250 ℃ for concrete and reinforcing steel, respectively. The temperatures were found to be approximately 380 ℃ and 100 ℃ in mist cases at depths of 5 cm and 10 cm, respectively, inside the concrete. CONCLUSIONS : The fire simulation studies indicated that the location of the maximum temperature was not directly above the fire, possibly because of fire-frame movements. During the final stage of the fire, the location of the highest temperature was immediately above the fire. During the fire in a tunnel with 27,000 liters of diesel, the maximum fire intensity was approximately 160 MW. The capacity of the fire source did not significantly affect the fire intensity, but affected the duration. Provided the concrete cover about 6 cm and 10 cm, both concrete and reinforcing steel can meet the required temperature limits of the Fire Resistance Design for Road Tunnel (MOLIT 2021). However, the results from this study are based on a few assumptions. Therefore, further studies should be conducted to include more specific numerical simulations and experimental tests that consider other variables, including tunnel shapes, fire sources, and locations.
공동주택 방화문의 화재성능 결함으로 인하여 하자소송이 확대되고, 화재발생 시 치명적일수 있다. 그러나 현행 법령은 이에대한 대책이 소홀한 편이다. 본 연구에서는 방화문의 결함과 특성 등을 잘 반영하고 있는 『강제창호 제작・품 질검수 매뉴얼』과 LH 설계・시방서 개정작업에서 드러난 문제점들에 대한 개 선방안을 제시하고자 한다. 방화문의 적정단가를 산정하고 내용연수를 합리적 으로 조정하며 3단계 점검시스템 등 관련규정을 신설 운영한다면, 방화문 품질 성능 향상과 화재시 입주민 보호에 크게 기여할 것으로 판단된다.
A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.
이 논문은 정적 재하상태에 있는 무피복 강합성보와 내화피복을 적용한 강합성보를 대상으로 화재 시 내부 온도 및 수직처짐에 대 한 내화피복의 영향을 평가한 결과를 제시한다. 열응력해석을 위한 화재하중으로는 American Society for Testing and Materials E119 의 표준화재곡선을 사용했으며, 강재거더 표면에 부착하는 내화재료의 방화효과를 구현하기 위해 외기에서 강합성보로 전달되는 열 의 전달계수를 감소시켰다. 실규모 무피복 강합성보에 대한 구조화재실험에서 내부 온도분포와 수직처짐을 측정하였고 실험 결과와 의 비교를 통해 비선형 구조화재해석 결과의 타당성을 검증하였다. 내화피복이 적용된 강합성보의 구조화재해석 결과로부터 강재거 더 표면에 내화재를 적용할 경우 동일 화재 조건에서 무피복 강합성보에 비해 내부 온도와 수직처짐이 감소함을 알 수 있었다. 또한 열 전달계수의 변화에 따른 열응력 응답으로부터 화재 시 강합성보의 온도 및 구조거동에 대한 내화피복의 영향을 제시하였다.
콘크리트 충전강관은 국부좌굴을 방지하고 내화성이 향상되기 때문에 건설현장에서 많이 적용되며 휨성능을 향상시 키기 위해 강관 내부에 철근을 보강하여 사용한다. 그러나 철근은 부식되며 내구성이 저하되기 때문에 이를 대신할 소재에 대 한 연구가 진행되고 있다. 탄소섬유보강근은 철근에 비해 경량이며 고강도와 내부식성이 우수하다는 이점이 있다. 그러나 임계 온도가 250℃로 철근의 임계온도인 538℃에 비해 현저히 낮기 때문에 내화피복이 필요하다. 따라서 열전달해석을 통해 탄소섬 유보강근을 사용하였을 때 온도분포를 확인하고 P-M상관도를 도출하여 적용 가능여부를 확인하고자 한다. 해석결과 내화성능을 확보하기 위해 콘크리트 피복두께 40mm, 뿜칠내화피복재 30mm를 적용하거나 콘크리트 피복두께 60mm, 뿜칠내화피복재 20mm 를 적용하면 3시간 내화성능을 만족하는 것으로 평가되었다.
교각의 내구성 증진 및 내진 보강을 위하여 원형철근 콘크리트 교각 외부에 강판을 보강한 경우, 교각 외부에서 발 생하는 화재에 대해 보강된 교각의 내화성능을 정량적으로 평가하였다. 범용유한요소해석프로그램 ABAQUS를 이용하였으며 ISO 834-1의 표준화재곡선을 적용하여 교각의 거동을 해석하였다. 해석 변수로는 강판보강두께와 원형교각 지름의 비, 교각에 수직으로 작용하는 축력비를 적용하였다. 교각의 상부와 하부는 힌지-롤러 경계조건을 고려하여 상부는 수직으로 변위가 발생하 도록 하였으며, 교각 외부 전체에 열하중을 가하였고 편심 없는 순수 축하중을 교각 중앙에 가력하였다. 온도에 따른 콘크리트, 철근 및 강재의 비열, 열전도율, 탄성계수 등을 고려하여 보강에 따른 교각의 내화 성능 향상도를 평가하였다. 강판으로 보강한 원형철근 콘크리트 교각은 콘크리트의 중심부일수록 강판 두께의 영향을 받지 않으며 강판 두께별 축력을 주 었을 때 내화시간은 축력비 0.7에서 최대 약 3분 향상되었다. 또한, 보강두께가 두꺼울수록 내하력이 향상하며 60분 이후에 모 두 내하력비가 1.0 이하로 감소하기 시작하는 것을 알 수 있었다. 강판보강공법은 내화성능을 향상시킬 수 있으며 강판 보강 두 께와 보강 지름의 비가 클수록 화재에 대해 축방향에 대한 변위와 내하력이 증가하는 것으로 나타났다. 본 연구결과를 토대로 원형철근 콘크리트 교각의 외부 강판 보강을 통하여 교각의 내화 성능을 향상시킬 수 있음을 정량적으로 판단할 수 있었다.
최근 들어 아라미드 섬유 시트는 건설 산업에 쉽게 사용되고 있다. 아라미드 섬유 시트는 높은 특성강도 및 강성, 높은 부식 저항성능, 경량 및 자기적 투명성과 같은 많은 장점을 제공한다. 본 연구에서는 아라미드 섬유 시트의 난연성능 및 접착강도가 연구되었다. 아라미드 섬유 보강 콘크리트 기둥의 내화성능은 표준 및 외부화재 곡선에 대해 서로 다른 조합의 보드 두께와 종류로 제작된 6개의 실험체를 사용하여 연구되었다. 그 결과 아라미드 섬유 시트는 마감재료를 이용해서 한 시간의 내화성능을 가지는 것으로 나타났다.
The basalt fiber is expected to become a trend for industrial fibers as they have better properties of heat-resistant, non-combustion, absorbent, soundproof, moistureproof, lightweight, corrosion resistant, and high strength properties. Also, the fiber is found to be non-toxic and harmless to the human body. Therefore, in this study, we analyzed the chemical and mineral compositions of powdered sludge of basalt produced at seven sites on Jeju Island for the development of fire resistance insulating material for a building. The results showed that the basalt stone sludge is made from only sodium calcium aluminum silicate and ferridioside components unlike the basalt rock.