        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Restraints of Branch Lines are used as earthquake-resistant support devices for fire-fighting pipes along with sway brace devices. The central types are aligned and fixed in a straight line with center of the pipe, but the eccentric types are fixed to on side of the pipe, so a bending moment occurs. In this study, three specimens each of central type and eccentric type were installed at an angle of 45° from the vertical and a monotonic compression load of 1340N was applied. All central type samples satisfied 17.8mm of the allowable displacement, but all eccentric type samples failed to meet the target load and buckled. Therefore, when considering the performance of eccentric type restraints, both compressive load and bending moment must be considered. Even through material mechanics calculations, the yield stress of eccentric type - 3/8 inch all threaded steel bolt - exceeds 320Mpa of the allowable stress. A experiment standards need to be established for eccentric type restraints.
        4,000원
        2.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is carried out to analyze the velocity distribution for each location and the uniformity index according to straight distance on exit side by changing the design factors of branch pipe connected to 180° circular mixing-tee using RSM(Reynolds Stress Model) turbulence model. As the results of the flow characteristics according to hydraulic diameter, the velocity profiles in the 90° sectional area are generally similar. In the 180° section, the maximum velocity point shows Y/D=0.7~0.8 after rapid increase of the flow velocity. In the result according to the distance away from inlet, the maximum velocity point in the 90° sectional area is located in outer side of the curved pipe as the distance away from inlet increases. In the 180° sectional area, the maximum velocity point is showed in Y/D=0.7~0.8 after the rapid increase of the flow velocity regardless of the variation of branched distance. In case of inclined angle, the maximum velocity point in the 90° sectional area is located in outer side of the curved pipe as the inclined angle increases. In the 180° sectional area, the maximum velocity point is observed in Y/D=0.8 regardless of the inclined angle. In addition, the uniformity index of flow velocity shows that it is stabilizing after approximately L/D=40 away from the end of the curved pipe regardless of the flow factors in the branch pipe.
        4,000원
        3.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to 16.3oC and 14.6oC during the experiment, respectively. The average water temperature in heating pipes was 52.3oC and 45.0oC, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of 5.71~7.49W/m2 oC. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.
        4,000원
        4.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Desalination plants have been recently constructed in many parts of the world due to water scarcity caused by population growth, industrialization and climate change. Most seawater desalination plants are designed with a submarine pipeline for intake and discharge. Submarine pipelines are installed directly on the bottom of the water body if the bottom is sandy and flat. Intake is located on a low-energy shoreline with minimal exposure to beach erosion, heavy storms, typhoons, tsunamis, or strong underwater currents. Typically, HDPE (High Density Polyethylene) pipes are used in such a configuration. Submarine pipelines cause many problems when they are not properly designed; HDPE pipelines can be floated or exposed to strong currents and wind or tidal action. This study examines the optimal design method for the trench depth of pipeline, analysis of on-bottom stability and dilution of the concentrate based on the desalination plant conducted at the Pacific coast of Peru, Chilca. As a result of this study, the submarine pipeline should be trenched at least below 1.8 m. The same direction of pipeline with the main wind is a key factor to achieve economic stability. The concentrate should be discharged as much as high position to yield high dilution rate.
        4,200원
        6.
        2007.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To improve the practical application of the thermal expansion of closed long pipeline exposing to external heating sources such as solar energy, safety engineering and system optimization for relief valve in the closed piping system are suggested through theoretical approach, correlation in view of temperature and pressure increase caused by external solar energy in the closed piping system. The profile for thermal relief valve including relieving capacity, influx heat energy, sizing criteria, set pressure, selection against back pressure is also presented. It is noted that following topic on solar relief valve should be applied to engineering, installation and commissioning.
        4,000원
        7.
        1983.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        접지전지 설계를 위한 Zn, Al 및 Mg의 합급양극의 특성을 실험적으로 조사한 결과를 다음과 같이 요약할 수 있다. 1. 환경비저항 1000 Ω.cm 이하에서는 Zn합금양극이, 1000 Ω.cm 이상에서는 Mg합금양극이 접지전지 설계에 좋다. 2. 비저항 500 Ω.cm 이하에서는 Al합금양극이 Mg 합금양극보다 접지전지 설계를 위한 유전양극 특성이 좋으나 모든 비저항에서 Zn합금양극보다 특성이 떨어진다. 3. 배유전유밀도가 급격히 증가하는 일정인가전압은 다음과 같다. ① E 하(Zn)=log (4.9465/σ상(0.0639))+11×10 상(-6)σ상(0.8923i) ② E 하(Al)=log (4.9306/σ상(0.0525))+13×10 상(-6)σ상(0.9314i) ˚led3 E 하(Mg)= log (3.7086/σ상(0.0988))+181×10 상(-6)σ상(0.5406i) 4. 유전양극의 종류 및 환경의 비저항에 따라 인가전압과 배유전유밀도의 관계는 다음과 같은 일반식으로 표시할 수 있다. logi=g+root(n.E+r)
        4,000원