        검색결과 15

        1.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the flexural capacity equation of FRP-bar reinforced concrete beams was verified by comparing the experimental results and flexural capacity obtained according to the ACI procedure. And, also the economic feasibility of FRP-bar reinforced concrete beams was analyzed by comparing nominal moment capacity of beams. The results of analysis were as follows, 1) GFRP concrete beams have lower flexural performance than reinforced concrete beams, whereas CFRP concrete beams have similar flexural performance to reinforced concrete beams under the same reinforcement ratio 2) Although the design moment increased as the compressive strength of concrete increased, the flexural performance of GFRP reinforced concrete beams was found to be lower than the reinforced concrete beams for all reinforcement ratios.
        4,000원
        2.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to develop a simple regression model in designing the asphalt concrete (AC) overlay thickness using the Mechanistic-empirical pavement design guide (MEPDG) program. METHODS: To establish the AC overlay design equation, multiple regression analyses were performed based on the synthetic database for AC thickness design, which was generated using the MEPDG program. The climate in Seoul city, a modified Hirsh model for determining dynamic modulus of asphalt material, and a new damaged master curve approach were used in this study. Meanwhile, the proposed rutting model developed in Seoul city was then used to calibrate the rutting model in the MEPDG program. The AC overlay design equation is a function of the total AC thickness, the ratio of AC overlay thickness and existing AC thickness, the ratio of existing AC modulus and AC overlay modulus, the subgrade condition, and the annual average daily truck traffic (AADTT). RESULTS: The regression model was verified by comparing the predicted AC thickness, the AADTT from the model and the MEPDG. The regression model shows a correlation coefficient of 0.98 in determining the AC thickness and 0.97 in determining AADTT. In addition, the data in Seoul city was used to validate the regression model. The result shows that correlation coefficient between the predicted and measured AADTT is 0.64. This indicates that the current model is more accuracy than the previous study which showed a correlation coefficient of 0.427. CONCLUSIONS: The high correlation coefficient values indicate that the regression equations can predict the AC thickness accurately.
        4,000원
        3.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Involved in a research for the application of seismic isolation to the nuclear industry, this study evaluates firstly the responses of seismic isolation system considering general ranges of structural period and damping ratio by using preliminary design formula. Secondly, coupling effects of input motions were evaluated to find out appropriate conditions of excitations and effect of the iteration for calculating yield displacement of lead core was also assessed in terms of response of a seismically isolated structure. Finally, the results of preliminary design calculation were compared with those of dynamic analysis and the propriety of the formula was evaluated and appropriate ranges of reduction factor were also suggested from the results.
        4,000원
        4.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현행 내진설계기준에서 RBS-B 접합부는 오직 중간모켄트골조(IMF) 시스템에서만 사용이 허용된다. 본 연구는 현행설계규준에 따라 설계한 RBS-B 접합부를 갖는 철골 모멘트골조 시스템의 내진성능평가를 수행하였다. 이를 위하여 층수(3층, 6층, 9층), 경간너비(6m, 9m), 내진설계범주(SDC C_{max}, SDC C_{min})으로 구성된 12개의 RBS-B접합부를 갖는 철골모멘트골조 건물을 설계하였고 RBS-B 접합부의 비선형 이력거동을 잘 모사하는 접합부 모델을 개발하였다. 설계된 대상골조는 ATC-63에 의해 개발된 내진성능평가방법에 따라 내진성능평가를 수행하였다. 또한 본 연구는 저자가 이전연구에서 제안한 새로운 설계법에 따라 설계된 IMF 시스템의 내진성능평가를 수행하였다. 그 결과 현행규준에 따라 설계한 몇 개의 대상골조가 적절한 붕괴여유비를 보유하지 못하였다. 반면에 새로운 설계절차에 따라 설계된 대상골조는 적절한 붕괴여유비를 보유하였다.
        4,000원
        6.
        2017.04 서비스 종료(열람 제한)
        The steel grid composite deck is a composite structure made of a concrete slab disposed over a steel grid. In this study, the punching shear strength obtained experimentally and the shear strength calculated by design equations of ACI 318 and Eurocode 2 are compared. The result shows that the experimental strength is best estimated by the design equation of Eurocode 2 which considers reinforcement ratio.
        7.
        2016.10 서비스 종료(열람 제한)
        The present study was conducted to appraise tow theoretical models for reinforced concrete members strengthened with carbon fiber reinforced polymer(CFRP) sheets. Predicted values using two models by ACI 440.2R-08 were compared with ones obtained from experiment. For this, two flexural specimens were tested: one unstrengthened specimen and the other strengthened with CFRP sheets. Based on the test results, the wow models are reliable by showing good agreement with the test results.
        8.
        2015.04 서비스 종료(열람 제한)
        This study reviews past literatures relevant to concrete beams using recycled aggregates (RAs) and investigate existing shear design equations for reinforced concrete (RC) beams. Then, a simplified, emprical design equation to determine the shear strength of high strength RC beams with RAs is proposed and compared with existing equations. The analysis indicated that the proposed equation provided the most accurate estimated of strength of high strength concrete beams with RAs.
        9.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        일반적으로 사용되는 철근콘크리트 교량의 바닥판에는 겨울철 과다한 염화칼슘의 사용과 그로인해 유발되는 성능저하로 인해 균열이 발생하고 수분이 침투하여 바닥판 내부의 철근이 부식됨으로써 균열이 생성 및 진전된다. 이러한 철근콘크리트 바닥판의 단점을 원천적으로 차단하기 위하여 바닥판 내부의 철근을 제거한 후 바닥판 외부에서 Steel strap을 이용하여 거더의 횡방향 거동을 구속시킴으로써 아칭효과를 극대화하고 내하력을 향상시킨 무철근 교량 바닥판이 최근에 개발 및 실용화되고 있다. 본 연구에서는 횡구속된 무철근 바닥판의 영향인자를 파악하기 위하여 콘크리트의 비선형성을 고려하였고 바닥판의 두께, 지간장 및 횡방향 구속강성도 등에 대하여 유한요소법을 이용한 매개변수해석을 수행했다. 또한, 이러한 해석결과를 활용하여 우리나라의 실정에 적합한 설계식을 제안하였다.
        10.
        2013.10 서비스 종료(열람 제한)
        In order to eliminate the defects of reinforced-concrete decks in terms of material, the steel-straped deck system is developed by maximizing the arching effect while the girders are restrained using straps in lateral direction to the bridge. In this paper, nonlinear FEA are performed for various parameters such as slab thickness, span length, strap spacing and sectional area, etc. in order to derive the equation to design the deck slab with steel-strap considering the minimum thickness of Korean design standards.
        11.
        2013.10 서비스 종료(열람 제한)
        In this study, by comparing the current steel structure design equations find out the problems, we will utilize to make the pipe-gusset joint equations. Representative equations CIDECT and AIJ-02 consider unreinforced and reinforced. As a result, there is some difference. therefore current equations decrease in reliability, in order to propose more accurate design equations need additional testing experimentation through finite element analysis
        12.
        2010.05 KCI 등재 서비스 종료(열람 제한)
        개구부의 여러가지 형상을 고려한 축하중에 대한 철근 콘크리트 벽체의 극한 강도를 연구하기 위하여 12개의 1/3축소벽체 실험을 수행하고 분석하였다. 벽체실험은 기존의 설계식을 수정하기위하여 구성되었다. 유효좌굴길이가 고려된 실험결과를 이용하여 새로운 실험식이 산출되었다. 이 새로운 설계식은 기존의 실험설계식과 비교하여 제안한다.
        13.
        2007.06 KCI 등재 서비스 종료(열람 제한)
        선체는 기본적으로 얇은 판부재들의 조합으로 구성되어 있으며 이들 중 상당수는 유공을 가진 유공판(Perforated plate)으로 이루어져있다. 선체에 설치된 유공판으로서는 선체 상갑판 해치(하역시설로 사용), 선저부의 거더와 플로어(중량경감과 선박 건조 및 검사시 통로확보용), 다이어프램(중량경감 및 파이프 관통의 목적)등이 있다. 이들 유공판에 압축하중이 작용하면 좌굴과 최종강도 특성이 크게 변화할 뿐만 아니라 수반되는 면내응력도 재 분포하게 되어 심각한 문제를 발생한다. 본 연구에서는 실선에서 사용 중인 유공보강판의 모델을 조사하여 비선형 유한요소법(ANSYS)을 사용하여 종방향 압축하중이 작용하는 경우에 대해서 유공비, 웹 치수, 웹 두께 그리고 보강재 단면을 변화시켜가며, 최종강도 시리즈 해석을 수행하고, 최종강도 예측 설계식을 제안하였으며, 식의 정도성을 검증하기 위하여 유한요소해석 결과와 비교하여 정도를 확인하였다. 제안된 설계식은 초기구조설계 시 유공보강판의 최종강도 계산에 유용하게 사용되리라 판단된다.
        14.
        2006.04 KCI 등재 서비스 종료(열람 제한)
        선체구조 부재에는 이중저의 거더 및 늑판 등에서 유공을 가진 판이 많이 사용되고 있고, 이는 중량 경감, 사람 및 화물의 이동, 배관 등의 목적으로, 보통은 강도상 큰 문제가 없는 부위에 위치하지만, 때로는 불가피하게 높은 응력이 작용하는 부위에 설치해야 할 경우도 있다. 이러한 판에 유공의 존재는 면내 하중에 의한 탄성좌굴강도 및 최종강도에 큰 영향을 주게 된다. 따라서 유공판의 탄성좌굴강도 및 최종강도 평가는 선박의 초기 구조설계단계에서 구조부재 치수를 결정할 때 검토해야 할 중요한 설계기준 중의 한가지 이다. 그러므로, 유공판에 대한 합리적인 신뢰적인 탄성좌굴강도 및 최종강도 평가가 필요시 되고 있으며 본 연구에서는 다양한 종횡비와 유공비 그리고 세장비의 영향을 고려하여 탄소성 대변형 유한요소 시리즈해석 결과를 바탕으로 하여 간단한 설계식을 도출하였다.