검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 40

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a vibrating nozzle using the waste vibration energy of the compressor body was installed in the suction flow path to improve the efficiency of the compressor through the pre-compression. To this end, the behavior of the suction valve according to the vibrating nozzle and the mass flow rate of the refrigerant entering the compression chamber were numerically analyzed. The results showed that the mass flow rate increased proportionally as the angle of the vibration nozzle increased. Among the profile shapes of the vibration nozzle, the concave or straight shape showed the highest mass flow rate. Considering the ease of machining, the straight shape is more favorable. On the other hand, as the operating frequency and stroke of the vibration nozzle increased, the mass flow rate also increased proportionally. It can be seen that the largest nozzle angle, operating frequency, and stroke are favorable for pre-compression unless the suction flow is restricted.. In the future, it is necessary to apply the vibrating nozzle system to an actual compressor model to experimentally check the compressor's cooling power, compression work and EER.
        4,000원
        2.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Abstract The compressor of a refrigerator accounts for approximately 60-80% of the total energy consumption necessary for the refrigeration cycle. This study investigates the implementation of a pre-compression system featuring a vibrating nozzle, with the goal of enhancing the efficiency of a linear compressor. By utilizing this pre-compression system, the cooling capacity and efficiency of the compressor are expected to improve. The numerical results show that the pre-compression system leads to an improvement of approximately 1.7% in cooling capacity compared to the baseline model. Furthermore, an increase of approximately 0.1 in EER was observed, confirming the feasibility of incorporating a pre-compression system with a vibrating nozzle.
        4,000원
        3.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to compare and analyze the conventional constant-speed compressor driven by an induction motor and the BLDC-applied capacity variable compressor in order to improve the energy efficiency of the refrigeration system. Through this study, it was found that, when a reciprocating hermetic compressor is operated, more power is consumed than a BLDC compressor due to the consumption of current through the instantaneous starting capacitor when operating at a constant voltage than a BLDC compressor.
        4,000원
        5.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 선박용 공기압축기의 상태기반보전 시스템에 필요한 이상치 탐지 알고리즘 적용에 대한 실험적 연구로서 고장모사 실험을 통해 시계열 전류 센서 데이터를 이용한 이상탐지 적용 가능성을 확인하였다. 고장 유형 10개에 대해 실험실 규모의 고장 모사 실험을 수행하여 정상 운전데이터와 고장 데이터를 구축하였다. 실험 결과 구축된 이상탐지 모델은 시계열 데이터의 주기에 변화를 유발하는 이상은 잘 탐지하는 반면 미세한 부하 변동에 대한 탐지 성능은 떨어졌다. 또한 오토인코더를 이용한 시계열 이상탐지 모델은 입력 시 퀀스의 길이와 초모수 조정에 따라 이상 탐지 성능이 상이한 것으로 나타났다.
        4,000원
        6.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The new thermal management models of linear compressors have been recently reported. These models adopt the simplified transient flow effects to shorten the excessive analysis time. Among the unsteady flow effects of the linear compressor, the effect of the gap flow between the compressor housing and the body due to the body vibration on the heat transfer performance was studied in this paper. For this study, a numerical analysis for the unsteady axisymmetric flows was performed by using CFD (Computational Fluid Dynamics). The results show that the high-speed refrigerant flows occurred in the gap between the compressor housing and the body, which contribute to increasing the heat transfer from high temperature refrigerants in the housing to the outside air. In addition, as the gap decreases, the refrigerant flow rate through the gap increases and the heat transfer rate increases as well.
        4,000원
        7.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Refrigerators used in homes occupy a large portion of the power consumption. In addition, most of the power consumption of the refrigerator is used by the compressor. Therefore, it is necessary to study on the improvement of compressor efficiency to save energy. In this study, the suction system was changed to improve the efficiency of the linear compressor. For this, numerical analysis was performed by linking the 1 dimensional lumped model and the 2 dimensional axisymmetric CFD model. The numerical analysis results were also compared with the experimental results. As a result of the numerical analysis, the model with modified suction system increased EER by about 0.25% compared to the basic model, which was also confirmed by experiment.
        4,000원
        9.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this theoretical study, a design and performance analysis theory of a micro flowrate and high pressure air-compressor is developed. The governing equations are from the gas state equation and fluid dynamic theories because the working fluid in the air compressor is in a gas phase. A case study was conducted to design a reciprocating type of air compressor which the target performance was 0.6liter/min in the volume flowrate with 5atg in air pressure at 1,600rpm rotational speed. Geometrical size of the model air compressor designed is 10mm in stroke, 20mm in bore with 4.79 compression ratio. From the performance analysis of the model compressor, it was found that the air volume flowrate produced was 0.6liter/min with 5.81atg in pressure. The design theory of a micro-size high-pressure air compressor developed in this study is expected to be very useful design tools in NANO technology industry.
        4,000원
        14.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Energy saving in household refrigerators becomes more important as the usage of household refrigerators have been increasing every year. Since a compressor in the refrigerator consumes more than 80% of its total energy, it is necessary to reduce the energy consumption of the compressor. In this paper, the convective heat transfer coefficients on the compressor housing for both natural convection and forced convection were measured. Then, the effect of convective heat transfer coefficient on the power consumption of a refrigerator was investigated using a thermal management analysis. The results showed that convective heat transfer coefficient for forced convection is higher by 7.8 W/m²K compared to the natural convection. In addition, through the thermal management analysis, it was found that the increase in convective heat transfer coefficient reduces the refrigerator power by about 4.8% improving EER by 0.9%.
        4,000원
        15.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The autoignition characteristics of n-heptane/n-butanol were investigated both experimentally and numerically. The effects of oxygen concentration and exhaust gas recirculation rate on the autoignition characteristics were evaluated. A rapid compression machine was employed to measure ignition delay times of blended fuels. A numerical study on the ignition delay time was performed using the CHEMKIN-PRO software to calculate ignition delay time and predict the chemical species in the combustion process. The results revealed that the ignition delay time increased with decreasing oxygen concentration due to the thermal load effect of nitrogen. The oxidation reaction of n-heptane in a low temperature regime was limited with decreasing oxygen concentration. The ignition delay time sharply decreased with exhaust gas recirculation because of the intermediate species in the exhaust gas. Exhaust gas recirculation reduced first ignition delay dramatically. However, the time interval between the first and main ignition increased with increased exhaust gas recirculation.
        4,000원
        17.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        왕복동식 압축기에서 피스톤과 커넥팅로드는 중요한 부분이다. 이러한 주요부에 기계적 부하가 과도하게 가해지면 해당 기부 속이 손상될 수 있으며, 교체하기도 쉽지 않고 비용도 많이 든다. 따라서 내구성과 수명에 영향을 미치는 요인을 분석할 필요가 있다. 본 연구의 주요 목적은 피스톤과 커넥팅로드의 최대 응력 집중 위치를 확인하는 것이다. 이를 위해 설계된 공기압축기의 작업 공정의 동적 계산을 기반으로 피스톤 및 커넥팅로드의 응력 분석을 수행하였다. 공기압축기의 피스톤과 커넥팅로드의 3 차원 모델을 따로 설계하고, 이러한 부품들의 유한요소 해석은 수치해석적인 근사해법을 사용하였다. 피스톤은 열 경계 조건 없이 크랭크 샤프트의 각도에 따라 압 력 부하를 받는다. 시뮬레이션 결과는 피스톤과 커넥팅로드의 응력 집중 위치와 그 값을 예측하고 추정할 수 있다. 그 결과 크랭크 각도 135°와 225°에서 피스톤은 190MPa, 커넥팅로드는 123MPa 이상의 최대 등가응력이 나타났으며 이는 인장 항복강도 이하의 값이다. 또한, 커넥팅로드와 피스톤에 계산 된 안전 계수는 1보다 높게 나타났다. 더욱이, 이러한 결과는 왕복동 공기압축기 제작사에 피스톤 및 커넥 팅로드를 설계함에 있어서 최적화를 위한 참고 자료로 활용 될 수 있다.
        4,000원
        18.
        2017.04 구독 인증기관·개인회원 무료
        The refrigerant temperature of a compressor increases due to heat generated in the discharge chamber and the motor. The increase of the suction temperature raises the superheat resulting in EER reduction. Thus, accurate superheat prediction is needed for the design of an efficient compressor. In this paper, the unsteady flow analysis is performed using CFD to predict the superheat. The results show that the suction temperature increases by about 26 °C which agrees well with the experiments.
        19.
        2017.04 구독 인증기관·개인회원 무료
        Abstract The increase of the superheat is one of several factors adversely affecting the efficiency of the refrigeration cycle. To this end, it is important to release the heat inside the compressor. Therefore, in this paper, we have increased the convective heat transfer coefficient inside the compressor by utilizing the vibration of the moving part of the compressor. The results show that reducing the gap between the shell and the moving part increases the flow velocity in the gap resulting in the increase of convective heat transfer coefficient.
        1 2