        1.
        2024.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In conventional construction practices, roof-parapet junction structures inevitably disrupt the insulation installation's continuity, leading to energy loss and thermal bridging. To address this issue, parapet thermal breaks were installed to interrupt the heat flow between the roof and the parapet, effectively preventing thermal bridging and energy loss and thereby reducing overall energy loss in buildings. This study equipped three experimental specimens with the developed parapet thermal breaks to verify their structural performance. These specimens were subjected to unidirectional loading under displacement-controlled conditions. The structural performance of these insulation structures was evaluated by comparing and analyzing the test results with corresponding analytical studies conducted using a finite element analysis program. In addition, five analytical models with varying parameters of the parapet thermal breaks were developed and compared against the baseline model. Consequently, the most efficient shape of the parapet thermal break was determined.
        4,000원
        2.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the structural safety of a structural thermal barrier, installed inside the structure of a building and performed the role of a load-bearing element and an insulation simultaneously, contributing to the realization of net-zero buildings. To ensure the reliability of the analysis model, the analysis results derived from LS-DYNA were compared with the experimental results. Based on the results shown through the flexural experiment, the reliability of the thermal cross-section insulation structure model for slabs was validated. In addition, the effect of the UHPC block on the load support performance and its contribution to vertical deflection was verified.
        4,000원
        3.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Climatologists have warned rapid climate change of the earth and it will cause a big disaster worldwide. the rapid climate change is mostly due to emission of greenhouse gases. To reduce greenhouse gases, many countries have prepared protocols, agreements, and treaties. IMO(International Maritime Organization) have established the protocol to decrease ship’s greenhouse gases emission and they consider the nuclear power source is an option to replace fossils fuels. Our study focused on elemental technologies related to a nuclear powered ship and, the passive residual heat removal system(PRHRS) is one of topics in our study. As the mandatory of the post Fukushima accident, PRHRS for a nuclear powered ship has been studied. We invented the new concepts of PRHRS which is optimized to a nuclear powered ship. The numerical analysis results indicated that the system is very reasonable. Based on the numerical analysis, an experiential loop was set and we preliminary tested the performance of the system under the reduced scale. The experimental results came with the numerical analysis results well.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
        4,000원
        7.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물외피 발생하는 열교현상은 건물의 단열성능 및 외피의 내구성에 영향을 미치며, 국내의 일반적인 주거형식인 공동주택의 발코니에 있어서 이러한 열교현상은 중요하게 고려되고 있다. 이와 같이 내·외부 발코니 슬래브 사이에서 발생하는 열교현상을 최소화하기 위한 목적으로 열교차단장치가 개발되었으며 다수의 건설현장에서 적용되고 있다. 철근콘크리트 슬래브 벽-슬래브 접합부에 열교차단장치를 적용함으로써 건물의 단열성능을 향상될 수 있으나 풍하중과 같은 양방향의 하중에 의해 열교차단장치 삽입부위가 적합한 구조성능을 확보하고 있는지에 대한 검증이 요구된다. 따라서 본 연구에서는 철근콘크리트 슬래브에 적용된 열교차단장치의 구조성능을 확인하기 위해 변위제어 방식으로 30 싸이클의 반복하중을 가력하였다. 열교차단장치가 삽입된 접합부는 요구되는 구조성능을 확보하며, 최대 모멘트강도, 에너지소산능력, 연성비가 기존의 철근콘크리트 슬래브와 비교하여 향상되는 것으로 나타났다.
        4,200원
        8.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근들어 철근콘크리트 슬래브와 벽의 연결부에 적용 가능한 열교차단장치에 대한 연구가 다수 수행되고 있다. 이에 본 연구에서는 열교차단장치가 적용된 슬래브의 균열 전 탄성거동, 균열 후 항복거동 및 극한강도까지 적용이 가능한 해석모델을 제안하고, 실험결과와의 비교를 통하여 제안 모델의 정확도를 검증하고자 하였다. 해석모델은 변형률 적합조건과 힘의 평형개념을 적용하였으며, 이 때 구성 재료의 응력-변형률 관계는 재료실험 결과를 적용하였다. 해석모델의 신뢰성 검증을 위해 모멘트-곡률 관계, 하중단계에 따른 중립축을 실험결과와 비교하였으며, 제안된 해석모델은 실험결과로 획득한 전체적인 휨거동 양상과 거의 일치함을 확인할 수 있었다.
        4,000원
        9.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance characteristics of a cascade refrigeration system with internal heat exchanger for cascade heat exchanger using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. This system considered in this study is consisted of a high temperature cycle using Freon refrigerant R23, R508B and low temperature cycle using Freon refrigerants R22, R507A. The operating parameters of this system include subcooling and superheating degree, evaporating temperature, compressor efficiency, and so on. The main results were summarized as follows : The COP of cascade refrigeration system using R23/R507A is the highest results in this study. The COP of cascade refrigeration system with internal heat exchanger only in high temperature cycle is the highest value among three cycle, such as only low temperature cycle, only high temperature cycle and all the cycle