Non-structural elements, such as equipment, are typically affixed to a building’s floor or ceiling and move in tandem with the structure during an earthquake. Seismic forces acting upon non-structural elements traverse the ground and the building’s structure. Considering this seismic load transmission mechanism, it becomes imperative to account for the interactions between soil, structure, and equipment, establishing seismic design procedures accordingly. In this study, a Soil-Structure-Equipment Interaction (SSEI) model is developed. Through seismic response analysis using this model, how the presence or absence of SSEI impacts equipment behavior is examined. Neglecting the SSEI aspect when assessing equipment responses results in an overly conservative evaluation of its seismic response. This emphasizes the necessity of proposing an analytical model and design methodology that adequately incorporate the interaction effect. Doing so enables the calculation of rational seismic forces and facilitates the seismic design of non-structural elements.
The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
최근 국내에서 발생한 경주지진 및 포항지진이 도심지 및 원자력발전소 주변에서 발생함에 따라 인근 주요 구조시스 템에 피해를 발생시킨 바 있다. 이에 따라, 본 연구는 원전 배관계통의 지진 거동 특성을 실험 및 해석적으로 규명하고, 이를 바탕으로 내진성능을 평가하는 연구를 수행하는 것을 목적으로 한다. 이를 위하여, 원전 배관계통을 대상으로 한 진동대 시험 결과를 바탕으로 배관 수치해석 모델을 수립하고 이를 시험 결과를 통하여 검증한다. 또한, 이러한 검증된 수치해석모델을 기반으로 배관계통의 내진성능을 평가한다. 수치해석 모델 검증 결과, 수립된 수치모델의 고유진동수, 감쇠비 및 변위 응답이 진동 대시험 결과와 유사한 것으로 나타났다. 이러한 검증된 수치모델을 바탕으로 평가된 내진성능 값은 기존 원전 배관의 내진성능 값의 범위와 비교적 유사한 값으로 평가되었다. 이는 설계기준지진을 크게 상회하는 값이지만, 원전 주요 기기 임을 감안할 때 추가적인 내진성능 상향이 확보되면 원전 지진 안전성 향상에 많은 기여를 할 수 있을 것으로 판단된다. 본 연구의 결과는 추후 원전 배관계통 내진성능평가를 위한 정량적인 자료로 활용이 가능할 것으로 판단된다.
액체저장탱크의 지진 거동은 유체-구조물 상호작용에 의해 복잡하게 나타나므로, 이 시스템의 지진응답과 피해를 정확하게 예측 하기 위해서는 이를 엄밀히 고려하여야 한다. 이 연구에서는 유체-구조물 상호작용을 엄밀히 고려하여 양방향 수평 지반운동이 작용 하는 직사각형 액체저장탱크의 지진응답 해석을 수행하고 그 응답 특성을 분석하고자 한다. 이를 위해 지진하중 작용 시 발생하는 유체 동수압을 유한요소 기법을 사용하여 산정하고, 이 동수압을 구조물의 유한 요소에 작용하여 전체 시스템의 동적 거동을 모사한다. 예제 직사각형 액체저장탱크의 지진응답 해석을 통하여 대상 시스템의 동적 거동은 양방향 수평 지반운동이 작용하는 방위각에 의해 유의미한 영향을 받음을 확인할 수 있다. 그러므로 직사각형 액체저장탱크의 내진설계를 수행하거나 내진성능을 검토할 때는 이러한 특성을 고려하여야 할 것이다.
In 2016, an earthquake occurred at Gyeongju, Korea. At the Wolsong site, the observed peak ground acceleration was lower than the operating basis earthquake (OBE) level of Wolsong nuclear power plant. However, the measured spectral acceleration value exceeded the spectral acceleration of the operating-basis earthquake (OBE) level in some sections of the response spectrum, resulting in a manual shutdown of the nuclear power plant. Analysis of the response spectra shape of the Gyeongju earthquake motion showed that the high-frequency components are stronger than the response spectra shape used in nuclear power plant design. Therefore, the seismic performance evaluation of structures and equipment of nuclear power plants should be made to reflect the characteristics of site-specific earthquakes. In general, the floor response spectrum shape at the installation site or the generalized response spectrum shape is used for the seismic performance evaluation of structures and equipment. In this study, a generalized response spectrum shape is proposed for seismic performance evaluation of structures and equipment for nuclear power plants. The proposed response spectrum shape reflects the characteristics of earthquake motion in Korea through earthquake hazard analysis, and it can be applied to structures and equipment at various locations.
In a seismic design, a structural demand by an earthquake load is determined by design response spectra. The ground motion is a three-dimensional movement; therefore, the design response spectra in each direction need to be assigned. However, in most design codes, an identical design response spectrum is used in two horizontal directions. Unlike these design criteria, a realistic seismic input motion should be applied for a seismic evaluation of structures. In this study, the definition of horizontal spectral acceleration representing the two-horizontal spectral acceleration is reviewed. Based on these methodologies, the horizontal responses of observed ground motions are calculated. The data used in the analysis are recorded accelerograms at the stations near the epicenters of recent earthquakes which are the 2007 Odeasan earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Geometric mean-based horizontal response spectra and maximum directional response spectrum are evaluated and their differences are compared over the period range. Statistical representation of the relations between geometric mean and maximum directional spectral acceleration for horizontal direction and spectral acceleration for vertical direction are also evaluated. Finally, discussions and suggestions to consider these different two horizontal directional spectral accelerations in the seismic performance evaluation are presented.
The site coefficients in the common requirements for seismic design codes, which were promulgated in 2017, were reevaluated and the standard design spectrum for soil sites were newly proposed in order to ensure the consistency of the standard design spectra for rock and soil sites specified in the common requirements. Using the 55 ground motions from domestic and overseas intraplate earthquakes, which were used to derive the standard design spectrum for rock sites, as rock outcropping motions, site response analyses of Korean soil were performed and its ground-motion-amplification was characterized. Then, the site coefficients for soil sites were reevaluated. Compared with the existing site coefficients, the newly proposed short-period site coefficient Fa increased and the long-period site coefficient Fv decreased overall. A new standard design spectrum for soil sites was proposed using the reevaluated site coefficients. When compared with the existing design spectrum, it could be seen that the proposed site coefficients and the standard design spectrum for soil sites were reasonably derived. They reflected the short-period characteristics of earthquake and soil in Korea.
The improvement in computing systems and sensor technologies devotes to conduct data-driven structural health monitoring algorithms for existing civil infrastructures. Despite of the development of techniques, the uncertainty oriented from the measurement results in the discrepancy to the actual structural parameters and let engineers or decision makers hesitate to adopt such techniques. Many studies have shown that the modal identification results can be affected by the uncertainties due to the applied methods and the types of loading. This paper aims to compare the performance of modal identification methods using Structural Modal Identification Toolsuite (SMIT) which has been developed to facilitate multiple identification methods with a user-friendly designed platform. The data fed into SMIT processes three stages for the comprehensive identification including preprocessing, eigenvalue estimation, and post-processing. The seismic and white noise response for shear frame model was obtained from numerical simulation. The identified modal parameters is compared to the actual modal parameters. In order to improve the quality of coherence in identified modal parameters, several hurdles including modal phase collinearity and extended modal amplitude coherence were introduced. Numerical simulation conducted on the 5 dof shear frame model were used to validate the effectiveness of using these parameters.
The first instrumental earthquake observation in Korea was started in 1905 by installing mechanical seismometers at the Incheon Observatory. Since then, the largest earthquake with a magnitude of 5.8 has occurred in Gyeongju in 2016. The seismic data on the Gyeongju earthquake are provided in the form of Mini Seed from the Korea National Earthquake Comprehensive Information System (http://necis.kma.go.kr/).
In this study, it is aimed to understand the response characteristics of Gyeongju seismic waves. The response spectra of El Centro, Taft and the 2016 Kumamoto earthquake are compared and analyzed.
In the response spectrum analysis, the acceleration response and the energy response were mainly considered.
As the number of high-rise buildings increases, a mid-story isolation system has been proposed for high-rise buildings. Due to structural problems, an appropriate isolation layer displacement is required for an isolation system. In this study, the mid-story isolation system was designed and the seismic response of the structure was investigated by varying the yield strength and the horizontal stiffness of the seismic isolation system. To do this, a model with an isolation layer at the bottom of 15th floor of a 20-story building was used as an example structure. Kobe(1995) and Nihonkai-Chubu(1983) earthquake are used as earthquake excitations. The yield strength and the horizontal stiffness of the seismic isolation system were varied to determine the seismic displacement and the story drift ratio of the structure. Based on the analytical results, as the yield strength and horizontal stiffness increase, the displacement of the isolation layer decreases. The story drift ratio decreases and then increases. The displacement of the isolation layer and the story drift ratio are inversely proportional. Increasing the displacement of the isolation layer to reduce the story drift ratio can cause the structure to become unstable. Therefore, an engineer should choose the appropriate yield strength and horizontal stiffness in consideration of the safety and efficiency of the structure when a mid-story isolation system for a high-rise building is designed.
In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.
Damages of large embankment dams by recent strong earthquakes in the world highlight the importance of seismic security of dams. Some of recent dam construction projects for water storage and hydropower are located in highly seismic zone, hence the seismic performance evaluation is an important issue. While state-of-the-art numerical analysis technology is generally utilized in practice for seismic performance evaluation of large dams, physical modeling is also carried out where new construction technology is involved or numerical analysis technology cannot simulate the behavior appropriately. Geotechnical centrifuge modeling is widely adopted in earthquake engineering to simulate the seismic behavior of large earth structures, but sometimes it can’t be applied for large embankment dams due to various limitations. This study proposes a dynamic centrifuge testing method for large embankment dams and evaluated its applicability. Scaling relations for a case which model scale and g-level are different could be derived considering the stress conditions and predominant period of the structure, which is equivalent to previously suggested scaling relations. The scaling principles and testing method could be verified by modified modeling of models using a model at different acceleration levels. Finally, its applicability was examined by centrifuge tests for an embankment dam in Korea.
According to natural frequency of soil, characteristics of earthquake responses of an isolated containment building in nuclear power plants are examined. For this, earthquake response analysis of seismically isolated containment buildings in nuclear power plants is carried out by strictly considering soil-structure interactions. The structure and near-field soil are modeled by the finite element method while far-field soil by consistent transmitting boundary. The equation of motion of a soil-structure interaction system under incident seismic wave is derived. The derived equations of motion are solved to carry out earthquake analysis of a seismically isolated soil-structure system. Generally, the results of this analysis show that seismic isolation significantly reduces the responses of the soil-structure system. However, if the natural frequency of the soil is similar to that of the soil-structure system, the responses of the containment buildings in nuclear power plants rather increases due to interactions in the system.
공간구조물은 높이-경간비 또는 개각과 같은 아치의 형상비에 따라 상이한 동적거동특성을 나타내며, 이러한 공간구조물은 지진의 영향을 직접적으로 받는 하부구조의 강성 및 그 접합부에 따라 상이한 지진응답특성을 나타낸다. 따라서 본 연구에서는 수직진동모드와 수평진동모드의 영향이 다른 단층아치구조에 하부기둥의 강성과 접합부에 따른 지진응답특성을 분석하고자 한다. 하부기둥의 영향으로 단층아치구조는 수직방향 응답이 더 많은 영향을 받으며, 기둥의 접합부 회전강성에 있어서는 활절을 제외하고는 큰 영향이 없는 것으로 나타난다.
본 연구의 목적은 에너지 흡수형 강재 댐퍼를 이용하여 손상순서를 제어함으로써 주구조체를 재사용 할 수 있는 철골조시스템을 개발하고, 지진응답특성을 파악하는 것이다. 이를 위하여 강재 댐퍼의 형상을 제안하고, 제안된 강재 댐퍼의 변형 형상과 응력 분포를 알아보기 위하여 범용 유한요소해석 프로그램인 ANSYS(ver.10.0)을 이용한 비선형 유한요소해석을 수행하였다. 또한 지진응답특성을 파악하기 위하여 실대형 사이즈 5.4m×2.4m의 1층 철골조 실험체 4개를 설계 및 제작하여 유사동적 지진응답실험을 수행하였다. 본 연구에서 제안하는 강재 댐퍼를 제진요소로 사용하는 경우, 주구조체에 비하여 높은 강성을 갖는 댐퍼가 소폭의 변위에 먼저 소성화함으로써 이력에 의한 지진에너지를 흡수할 수 있으며, 지진응답에서 유리한 것이 판명되었다.
원자력발전소에 설치되는 주요 전기기기들의 내부 부품을 내진검증하기 위해서는 캐비닛내부응답스펙트럼이 필요하고, 이는 캐비닛의 각 위치에서 정확한 지진응답을 구한 후에 생성이 가능하다. 반면에 대부분의 전기기기는 질량과 강성 분포가 복잡하기 때문에 해석적 방법에 의해 동적 분석을 수행하는 것이 어렵다. 이러한 여건을 감안하여 이 연구에서는 해석과 시험을 조합하여 기기의 지진응답을 예측하는 간편한 절차를 제안하였다. 제안된 절차는 먼저 충격시험을 통하여 규명된 실험모드특성을 이용하여 독립된 모드방정식을 구성하고, 이로부터 모드응답을 계산한 다음, 각 모드응답을 중첩함으로써 구조물의 지진응답을 예측한다. 제안된 절차의 신뢰성을 검증하기 위해서, 별도로 제작된 단순 강재 프레임 시편에 제안된 절차를 적용하여 지진응답을 예측하고, 이를 실제 진동대시험을 통하여 계측한 결과와 비교하였다. 이 연구를 통하여 충격시험에 의해 얻어진 실험모드특성을 이용하여 구조물의 지진응답을 비교적 정확하게 예측할 수 있음을 확인하였다.
본 연구에서는 원전 주제어실의 층 지진격리시스템에 대한 지진동 저감성능과 적용성을 평가하기 위해서 실험연구를 수행하였다. 층 지진격리시스템에 적용하기 위해서 납-고무 베어링(LRB)과 마찰진자장치(FPS)를 설계하고 제작하였다. 제어 캐비닛과 액세스 플로어로 구성된 원전 주제어실 부분 실험모형을 제작하여 납-고무 베어링과 마찰진자장치를 각각 설치하여 진동대 실험을 수행하여 지진응답특성을 비교, 평가하였다. 실험을 위해서 원전 주제어실의 운전기준지진(OBE)과 안전정지지진(SSE)의 수평방향 층응답 스펙트럼을 이용하여 인공지진 시간이력을 만들어서 진동대 실험에 사용하였다. 입력지진에 대한 실험모형의 지진응답은 마찰진자장치를 적용한 경우 상대적으로 우수한 지진동 저감특성을 나타냈다.
본 논문에서는 반복하중에 의한 반복 경화 및 연화 현상을 나타낼 수 있는 수정 IWAN 모델을 이용하여, 1차원 비선형 부지응답 해석프로그램(이하 KODSAP; Kaist One Dimensional Site-response Analysis Program)을 개발하였다. 개발된 프로그램은 지진하중 재하에 따른 지반의 반복경화 및 연화현상에 의한 부지응답 특성 변화를 재현할 수 있다. KODSAP을 이용하여 기반암 상부 40m인 모형지반의 반복경화 및 연화 정도, 지진가속도의 크기에 따른 부지응답특성 변화를 살펴 보았으며, 현재 실무에서 널리 적용되고 있는 등가선형, 비선형해석과 KODSAP 해석결과(지반의 반복경화 및 연화현상을 고려한)과의 차이점을 살펴 보았다.
대부분의 대공간구조물은 극장, 스타디움, 체육관 등 공공성을 가지게 되어 내진안전성에 있어서 중요성이 많이 인식되고 있다. 그러나 구조형식 및 형상에 관하여 다양성을 가지고 있는 대공간구조물이 동적하중인 지진하중을 받을 때 나타나는 구조물의 거동은 파악하기 힘들다. 본 논문에서는 대공간구조의 주 구조요소인 아치구조물에 대하여 고유진동모드를 검토하였고 모의지진파를 입력하여 지진거동특성을 분석한 결과로서 아치구조물은 설계가속도스펙트럼의 크기보다 장주기 성분에 더 많은 영향을 받는다는 것을 파악하였다.
건축물의 지진응답해석에서 입력지진동은 구조물의 비선형 응답에 중요한 영향을 미치는 요소이다. 지진동의 특성은 표층지반의 성질과 국부적인 지반 조건에 따른 여러 가지 인자에 의해 그 특성이 결정되기 때문에 구조물의 지진응답해석에서 일반성을 갖는 입력지진동을 선정하는 것은 매우 어려운 문제이다. 본 논문은 내진설계용 스펙트럼에 적합한 인공지진동파형을 작성한 후, 작성된 인공지진동에 의한 철근콘크리트 다층 골조구조물의 탄소성 응답특성을 분석한 것이다. 여기서 작성된 인공지진동파형은 과거 비교적 큰 규모의 지진에서 얻어진 기록지진동과 동일한 위상각을 가지며, 감쇠정수 h=5%일 때의 내진설계용 스펙트럼과 거의 일치하도록 작성하였다. 입력지진동의 탄성 가속도 응답스펙트럼이 동일한반면, 각 입력지진동띄 위상특성이 다른 인공지진동을 입력하여 다자유도 골조 구조물의 지진응답을 분석하여 건축물의 내진설계용 지진동으로서 타당성을 확인하는 것이 목적이다. 본 논문에서 작성된 인공지진동은 기록지진동에 비해 지진응답치가 안정된 값을 나타내는 것을 확인할 수 있었다. 그러므로 다층 골조구조물의 비선형 지진응답해석용 입력지진동으로 타당성이 높다고 사료되며, 비선형 지진응답해석용 입력지진동의 강도를 탄성 가속도 응답스펙트럼으로 규준화 하는 것이 합리적이라고 사료된다.