2017년 6월에 영구정지 된 고리 1호기의 해체는 한국의 상업 원전에 대한 첫 해체 사례가 될 것이다. 해체 과정 중에 발생하 는 폐기물에 대한 처분은 전체 해체 비용의 많은 부분을 차지한다. 따라서 방사화 및 오염된 콘크리트 구조물은 적절한 해체 전략을 수립하여 경제적이고 안전하게 해체되어야 한다. 본 논문에서는 생물학적 차폐체에 대한 최적화된 해체 및 처분 시 나리오를 연구하였다. 해체사례, 폐기물 처분 규정 및 처리 기술을 분석하였다. 그리고 생물학적 차폐체 제거 과정의 폐기물 발생량을 최소화하기 위해서, 최적 해체 시나리오를 제시하였고 폐기물 처분 방안을 도출하였다.
Because the lens is a tissue with the highest sensitivity, the lens shielding is very important in CT imaging. However, in clinical terms, there is a lack in the efforts in decreasing dosage on the lens, and the shielding of dosage and the effects on the imaging are researched using bismuth to evaluate the usefulness. As results of the dosage evaluation results, when there is no gantry angle when the thickness of the lens shielding material is 0mm, the dosage was 28.476mGy, and when there is gantry angle, the dosage was 20.852mGy that it was confirmed that the dosage was 27% lesser with gantry angle. It was confirmed that the dosage value decreased with the increase of thickness of lens shielding material when there is gantry angle, and when the lens shielding material was 1mm, the dosage decreased by approximately 39% compared to when it was 0mm. When there is gantry angle, the dosage values were respectively 12.788mGy and 12.776mGy for the crystalline lens shielding material thicknesses of 0.75mm and 1.0mm. In image analysis, the quantitative evaluation and the qualitative evaluation were almost constant regardless of the thickness of the lens shielding material. The optimal lens shielding material thickness to minimize the does of lens and increase the value of diagnosis in Brain CT examination is 0.75mm. Therefore, if this is utilized for easier use in clinical practices, it is considered to be able to contribute to not only the protection of the lens but the accurate diagnosis of diseases.
The number of CT gradually tends to increase, but radiation exposure includes higher exposure dose of patients than other test methods as the rate of 67% in the whole radiology tests. Exposure dose of patients has increased due to it and the second exposure has been done by scattered rays of other organs except for test sites. Especially, special shielding has not been done in gonad which is very sensitive to radiation in brain and chest CT. So this study tries to research the second exposure dose of the gonad and how to shield it in Chest CT which does not include it. It was intended for 20 male adults who are 30 years old and conduct chest CT. SIEMENS’s SOMATOM DEFINITION AS* was used as CT equipment. For the scanning conditions, The tube voltage is 120kv, the tube current is 90mAs, and the slice thickness is 3mm as the general chest CT conditions. CHIYODA TECHNOL CORPORATION’s FGD1000 was used as Glass dosimeter (PLD). A lead pad of 0.25mmPb was produced as the shielding board. For the research method, the shielding rate was compared by measuring exposure dose of the gonad before and after shielding and the usefulness of the shielding board was evaluated. The average exposure dose of symphysis pubica before shielding was 280.5μGy and the average exposure dose of coccyx was measured as 151.5μGy. The average exposure dose of symphysis pubica after shielding the gonad with a lead pad of 0.25mmPb was 42μGy and the average exposure dose of coccyx was measured as 41μGy.
It is essential to develop the shield for the extraction of high quality neutron beam and safe work at the sample position. The aim of this study is design, fabrication and filling of the shield in domestic. In consideration of ST-3 beam port of HANARO, we designed the reflectometer shield composed of 14 blocks and fabricated it shield casemate. Through the assembly and quality test of the shield casemate, we established the method of fabrication for neutron beam path and channel. In order to increase shield capacity, we filled shield casemate with heavy concrete, lead ingot and polyethylene that mixed B4C powder and epoxy. The average density of the filled heavy concrete was 4.7g/cm3, which can protect neutron and gamma ray effectively. Also, we developed ancillary equipment such as beam gate unit(BGU, vertical type) for the effective opening and closing of neutron beam. Shielding block was proved by suitable thickness as result that measure surface dosage using of detector and TLD. The acquired technique of design, fabrication and filling of ancillary equipment development can be applicable to the development of shield for the other neutron spectrometer in future.
최근 의료분야에서 X선은 질병의 진단 및 치료영역에서 필수적으로 요구되며, 영상의학 기술의 발전과 더불어 X선의 이용은 지속적으로 증가하는 추세지만, X선은 방사선 피폭의 단점을 가지고 있다. 방사선피폭을 방어하기 위해 임상에서는 납 방호도구를 사용하지만 납은 중금속으로 분류되어 납중독 등 인체에 유해한 반응을 일으킬 수 있다. 따라서 본 연구는 FDM(Fused Deposition Modeling)방식의 3차원 프린터의 재료를 이용하여 제작한 차폐체의 유용성을 알아보고자 한다. 필라멘트의 선감약계수를 확인하기 위해 PL A, XT-CF20, Wood, Glow, Brass를 이용해 팬텀을 제작 하고, CT scan을 하였다. 그리고 100 × 100 × 2 ㎜ 크기의 차폐 시트를 모델링하고, 진단용 X선발생장치와 조사선량계를 이용하여 선량 및 차폐율을 측정하였으며, 납 방호도구와의 차폐율을 비교하였다. 실험결과 Brass의 CT number가 가장 높게 측정되어 Brass를 이용하여 차폐시트를 제작하였으며, 진단용 X선발생장치로 확인한 결과 100 kV, 40 mAs 조건으로 X선 조사 시 6 ㎜ 두께의 차폐시트에서 차폐율이 90 % 이상으로 측정되어 apron 0.25 ㎜Pb보다 차폐율이 높은 것을 확인하였다. 본 연구의 결과 3차원 프린팅 기술로 제작한 차폐체가 진단용 X선 영역에서 높은 차폐율을 보이는 것을 확인하였으며, 납 방호도구와의 비교를 통하여 납을 대체하여 방사선 방호도구로서의 가능성을 알 수 있었다.
전산화단층검사는 많은 방사선을 받을 수 있으며, 한 명의 환자에서 반복적으로 시행되는 경우가 위험도 는 매우 높다. 어린이의 경우에 방사선에 의한 암 발생률이 더 높다고 보고하고 있다. 3D 프린트는 여러 분야에 적용하기 위해서 연구되고 있으며, 여러 응용 분야중 방사선 차폐체 제작 및 재료에 대한 연구가 최근 진행되고 있다. 3D 프린터의 목적은 기존의 판넬 형태의 차폐체를 대체하고 인체의 형태를 따라 맞춤형 제작을 하는 것이 최종 목적이기 때문에 3D 프린터에 입력할 3차원정보처리에 대한 연구도 매우 중요하다. 본 연구에서는 스테레오 비전의 깊이지도(depth map) 생성 기술을 이용하여 환자 맞춤형 안구차폐체 제작의 전단계인 인체표면의 3차원 데이터를 계산하고 활용 가능성을 연구하고자 하였다. 알려진 3차원 정보처리의 방법들에 비해서 비교적 간단한 방법으로 제안된 결과 안면부 3차원 정보추출을 위한 최소한의 정보가 추출되었다. 본 연구의 결과는 자연광을 적용한 스테레오영상의 장점과 한계점을 제공하였고 향후 안구 차폐체 제작을 위한 기초자료가 될 것으로 판단한다.