        1.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        2.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
        4,200원
        3.
        2014.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        RC shear wall sections which have irregular shapes such as T, ㄱ, ㄷ sections are typically used in low-rise buildings in Korea. Pushover analysis of building containing such members costs a lot of computation time and needs professional knowledge since it requires complicated modeling and, sometimes, fails to converge. In this study, a method using an equivalent column element for the shear wall is proposed. The equivalent column element consists of an elastic column, an inelastic rotational spring, and rigid beams. The inelastic properties of the rotational spring represent the nonlinear behavior of the shearwall and are obtained from the section analysis results and moment distribution for the member. The use of an axial force to compensate the difference in the axial deformation between the equivalent column element and the actual shear wall is also proposed. The proposed method is applied for the pushover analysis of a 5- story shear wall-frame building and the results are compared with ones using the fiber elements. The comparison shows that the inelastic behavior at the same drift was comparable. However, the performance points estimated using the pushover curves showed some deviations, which seem to be caused by the differences of estimated yield point and damping ratios.
        4,000원
        4.
        2012.03 구독 인증기관 무료, 개인회원 유료
        The interest for the stability of the structures against earthquake, which is increasing recently, is rapidly increasing. But, currently, school buildings among the reinforced concrete(RC) structures in Korea are not designed with seismic design or there are many cases of being designed with the old seismic design code, so it is estimated to have not only lives but also a great deal of economic damage are likely to occur when an earthquake occurs. In this study, proposed horizontal friction system(HFS) with rotary friction damper installed as a method to reinforce strength and hardness and to increase ductility for the low story structure of 5 stories or lower such as school buildings. For the seismic retrofitting design with horizontal friction system in which rotary friction damper is installed, Peak displacement response ratio according to elastic and inelastic behavior and ductility demand is calculated to decide elastic stiffness and strength of the HFS, design model and procedure to decide the capacity of HFS thereof is decided, and the feasibility and performance are reviewed through pushover analysis.
        4,000원
        5.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고정반복법에 의한 암시적 HHT 시간적분법을 이용하여 3층 3경간 철근콘크리트 골조구조물을 수치해석모형과 물리적 분구조모형으로 나누어 실시간 하이브리드실험을 실시하였다. 물리적 부분구조모형으로는 1층 내부 비연성기둥 1개소가 선택되었고, 수치해석모형에 일축 방향의 지진하중을 시편이 심한 손상에 의하여 파괴에 이를 때까지 작용시켰다. 비선형 유한요소해석 프로그램인 Mercury가 실시간 하이브리드실험을 위하여 새로이 개발 및 적용되었다. 실험결과는 물리적 부분구조모형의 상부 수평방향 층간변위비를 OpenSees에 의한 수치해석시뮬레이션과 진동대실험의 그것과 비교하였다. 본 실험은 가장 복잡한 실시간 하이브리드실험 중의 하나이고, 하드웨어, 알고리즘 그리고 모형에 대한 기술적인 내용을 본 논문에 자세히 설명하였다. 수치해석모형의 개선, 물리적 부분구조 모형 접선강성행렬의 유한요소해석 프로그램에서의 평가 그리고 하중기반 보-요소의 요소상태결정의 연산시간을 줄이기 위한 소프트웨어의 개선이 이루어진다면 실시간 하이브리드실험과 진동대실험결과의 비교는 권장할 만하다. 그리고 "지진과 같은 동적하중하의 복잡한 구조물의 수치해석시뮬레이션"이라는 목적을 위하여 실시간 하이브리드실험은 동적하중에 대한 실험적 검증을 점진적으로 수치해석모형으로 대체하기 위한 저비용-고효율 실험법으로서의 가치를 충분히 가지고 있다고 할 수 있다.
        4,600원