This study evaluates the performance of three theoretical models for correcting dynamic pressure affected by tube length. The experiments involved measuring sinusoidal pressure waves with varying frequency bandwidths, using tubing systems ranging from 20 cm to 300 cm in length including multiple tubing systems connecting three or more tubes. The results showed that the Bergh and Tijdeman models, with constant and variable polytropic parameters respectively, had superior correction performance for various tube lengths, while the Whitmore & Leondes model showed discrepancies. The Bergh & Tijdeman model, with a polytropic parameter of 1.4, is recommended due to its convenience and accuracy. Furthermore, including the inner volume of the pressure transducer in the theoretical model was found to be crucial for accurate correction, as not doing so caused significant errors. The Bergh & Tijdeman model was also found to efficiently correct tube length effects in multiple tubing systems, eliminating the need for time-consuming and laborious experiments.
In this study the characteristics of wind pressure that are depending on the open type of retractable dome roof were analyzed according to the wind pressure coefficient and wind pressure spectrum. The analysis results showed that the open type and shape of the roof both had a significant impact on the wind pressure changing. In case of the edge to center open type, the wind pressure has not changed much because of the complex turbulence of flow and open area. On the other hand, in case of the center to edge open type, it has confirmed that wind pressure increases due to the separation of flow in windward and open area.
This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.
The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.
Spatial Structure has suffered from a lot of damage due to the use of lightweight roofs. Among them, the damage caused by strong winds was the greatest, and the failure of the calculation of the wind load was the most frequent cause. It provides that wind tunnel test is used to calculate the wind load. However, it is often the case that the wind load is calculated based on the standard of wind load in the development design stage. Therefore based on this, the structure type and structural system and member design are often determined. Spatial structure is usually open at a certain area. The retractable roof structure should be operated with the open roof in some cases, so the wind load for the open shape should be considered, but it is not clear on the basis of the wind load standard. In this paper, the design wind pressure of a closed and retractable roof structure is calculated by KBC2016, AIJ2004, ASCE7-10, EN2005, and the applicability of wind pressure coefficient is compared with wind tunnel test.
There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.
대공간 건축물의 특징 중 경량화 된 지붕 구조 및 재료의 사용으로 인해 지붕면의 손상이나 파괴 등의 피해가 많다. 대규모 경기장의 경우에는 지붕의 구조가 철골 트러스와 인장케이블을 기반으로 테프론이라는 막재료를 사용하여 구조체를 감싸거나 덮는 형태로 많이 설계가 되는데, 특히 이 막재료의 피해가 많으며 심각한 상황이다. 이러한 사례를 통해 대공간 건축물의 지붕에 대한 내풍설계 연구는 아직 미흡한 상태임을 알 수 있다. 본 논문은 쌍곡포물선 대공간구조물의 지붕의 형태에 대한 공기역학적인 특성을 알아보기 위하여 풍압실험과 유체해석을 실시하였다. 실험결과 바람이 불어오는 방향의 지붕 모서리에서 가장 큰 최소피크외압계수가 나타나지만 지붕의 길이방향으로 갈수록 최소피크풍압계수는 감소하고 있었다.
바람에 의한 초고층 건축물의 거동은 매우 복잡하기 때문에 구조체에 대한 풍하중의 설계는 매우 어렵다. 현재 사용되고 있는 풍하중 산출방법은 풍동실험에 의존하고 있으며, 1차 탄성거동을 전제로 행해지고 있다. 가장 불리한 조건인 1차 모드로 가정하는 것은 다소 과대설계가 되어 안전하지만, 비경제적이다. 따라서 초고층 건축물에 작용하는 풍하중은 다차 모드 해석에 의해 산출하는 것이 안전성과 경제성을 동시에 확보할 수 있는 방법일 것이라 판단된다. 다차 모드를 고려한 풍하중의 산정은 풍압적분법(Pressure Integral Method)을 응용하면 가능하다. 본 연구는 풍압적분법(Pressure Integral Method)의 유효성을 검증하는 것이 목적이며, 공력진동실험에 의한 풍응답 해석결과와 비교하여 그 유효성을 검증하였다.
중정형 건축물의 중정측 외장재 설계를 위한 외압계수분포 특징을 알아보기 위해 풍압실험을 실시하였다. 본 연구를 위하여 형상비와 중정의 폭을 변화시킨 4개의 모형을 제작하였으며, 풍동실험은 금오공과대학교 토출식 경계층풍동에서 실시하였다. 본 연구의 결과로부터 중정측의 외압계수는 건물외측의 외압계수보다 감소하는 것으로 나타났다.
이 연구의 목적은 풍압적분법의 유효성을 검증하는 것이다. 기존의 풍하중 산정은 풍력실험을 통해 얻어진 시계열 풍력데이터에 대해 스펙트럼모드해석법을 수행하여 평가하는 방법에 주로 의존하였다. 이 방법은 건축물의 진동모드로 선형모드를 사용하기 때문에 비정형적인 건축물의 풍하중해석이나 다자유도해석에는 한계가 있다. 풍압적분법은 다자유도해석 및 비정형적인 건축물의 풍하중을 보다 정확히 산정할 수 있는 방법이다. 본 연구에서는 풍압적분법에 의해 평가한 풍하중과 풍력실험결과에 의해 평가한 풍하중을 비교하였다. 그 결과 두 방법에 의해 평가한 풍하중은 매우 유사한 것으로 나타났다. 풍압적분법은 복잡한 형상을 가진 건축물에 대한 풍하중을 평가할 경우 풍력실험을 대체할 수 있다는 유효한 수단으로 사용할 수 있다.
컨테이너 크레인에 대한 풍하중 분포를 조사하기 위하여 대기경계층풍동에서 풍압실험이 수행 되었다. 본 풍압실험의 목적은 크게 두 가지로서 (1) 구조해석을 위한 입력 풍하중 데이터, (2) 전산유동 해석을 위한 표면압력분포 데이터를 확보하기 위한 것이다. 1/70으로 축소된 모형에 464개의 압력공을 설치하여 표면 압력 분포를 구하였다. 국부적인 지점의 압력값 으로부터 표면위의 평균 풍하중을 산정하기 위하여 직육면체의 모형을 제작하여 면의 경사도에 따른 압력값과 하중값의 비를 실험적으로 구하였다. 크레인형상의 특성과 관련하여 레이놀즈수의 영향, 압력튜브시스템의 설계 등에 관하여 논의한다.