Climatologists have warned rapid climate change of the earth and it will cause a big disaster worldwide. the rapid climate change is mostly due to emission of greenhouse gases. To reduce greenhouse gases, many countries have prepared protocols, agreements, and treaties. IMO(International Maritime Organization) have established the protocol to decrease ship’s greenhouse gases emission and they consider the nuclear power source is an option to replace fossils fuels. Our study focused on elemental technologies related to a nuclear powered ship and, the passive residual heat removal system(PRHRS) is one of topics in our study. As the mandatory of the post Fukushima accident, PRHRS for a nuclear powered ship has been studied. We invented the new concepts of PRHRS which is optimized to a nuclear powered ship. The numerical analysis results indicated that the system is very reasonable. Based on the numerical analysis, an experiential loop was set and we preliminary tested the performance of the system under the reduced scale. The experimental results came with the numerical analysis results well.
Recently, the importance of air filters used in air purifiers and ventilation systems is emphasized in Korea. As a result, air filter test reports are required by users to ensure the removal efficiency of particulate matter. However, the tests are conducted for the filter material alone, which lead to a possible discrepancy between the test report and actual efficiency when applied to actual devices. Therefore, in this study, the removal efficiency data of the filter test reports were compared with actual filter efficiency data after application to the ventilation systems for some ventilation systems in the market. For ventilation system A, the field test results using filter leakage test method were slightly lower than those in the test report but nearly the same. For ventilation system B, the field test result was much higher than reported in the test report. This was due to the broad range of particle sizes measured using the filter leakage test method. The field tests using the particle counter method showed that the removal efficiency of ventilation system A for 0.3 μm was under 50% which translates to less than half of those of the filter test reports. For ventilation system B, the removal efficiency was 15%~21%. much lower than reported in the filter test reports. The lower removal efficiencys are mainly assumed to be caused by leakage of the filter installation among other factors. Therefore, the field test methods for the particulate matter removal efficiency of ventilation systems should be established to verify actual efficiency and improve the efficiency in the future.
The Air-shiter is a new product possible ventilation at the same time cooling or heating with combined refrigerator and heat recovery ventilator. And a key device of this system is the air shifter. The air shifter device is to convert the outdoor air, room air, supply air and exhaust air flow. Therefore, an experimental study has been carried out to investigate the operating performance for this system. The results, it is possible to ventilate at the same time of heating by outside air above 30℃ in summer. and of heating by outside air within 3℃ in winter. The indoor discharge temperature is over 40℃, and the coefficient of performance is 3.4 in winter.
In this paper, cycle performance characteristics of a cascade refrigeration system with internal heat exchanger for cascade heat exchanger using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. This system considered in this study is consisted of a high temperature cycle using Freon refrigerant R23, R508B and low temperature cycle using Freon refrigerants R22, R507A. The operating parameters of this system include subcooling and superheating degree, evaporating temperature, compressor efficiency, and so on. The main results were summarized as follows : The COP of cascade refrigeration system using R23/R507A is the highest results in this study. The COP of cascade refrigeration system with internal heat exchanger only in high temperature cycle is the highest value among three cycle, such as only low temperature cycle, only high temperature cycle and all the cycle
측고, 연동수, 측창의 유무 및 천창의 위치에 따른 다연동 온실의 환기성능을 평가하기 위하여 다양한 유형의 연동 플라스틱 온실을 대상으로 실제 농가의 재배현장에서 환경계측 실험을 수행하였다. 실험 대상 온실은 모두 토마토를 수경재배하고 있는 농가였으며, 열수지 방법으로 환기율을 비교 분석하였다. 측고가 4m인 온실은 측고가 2m인 온실에 비하여 22% 정도의 환기율이 증가하는 것으로 나타났다. 9연동 온실은 5연동 온실에 비하여 17% 정도의 환기율이 감소하는 것으로 나타났다. 9연동 온실에서 측창이 없는 경우에는 측창을 설치한 경우 보다 환기율이 1/3 정도로 낮게 나타났다. 전체적으로 다연동 온실의 환기성능은 측고가 높을수록 좋고, 연동수가 많을수록 떨어지며, 측창이 없으면 현저하게 저하하는 것으로 나타났다. 또한, 측고가 높고 천창을 용마루에 설치한 경우의 환기성능이 가장 우수한 것으로 나타났다. 따라서 다연동 온실의 자연환기 성능을 극대화하기 위해서는 온실의 측고는 높이고, 지붕 환기창의 위치는 곡부가 아니라 용마루에 설치하며, 측창을 반드시 설치하고, 연동수는 10연동 내외로 제한하는 등의 구조개선이 필요하다.
온실의 환기설계 기준 설정 및 단동 플라스틱 온실의 원형 천창 설치 가이드라인 제정을 위한 기초자료를 제공할 목적으로 천창이 설치된 토마토 재배 단동 온실에서 환기실험을 통하여 자연환기 성능을 분석하고, 열평형 모델을 이용하여 온실 재배 토마토의 증발 추정하였다. 직경 60cm의 원형 천창을 지붕의 중앙에 8m 간격으로 설치한 단동온실의 자연환기 성능을 실험한 결과 환기회수는 분당 0.02~0.32회(평균 0.17회 min-1)의 범위를 보여 상당히 낮은 것으로 나타났다. 그러나 상업용 온실의 권장환기율과 비교하면 6m 간격으로 설치할 경우에는 봄이나 가을철에 필요한 환기량을 충족할 수 있을 것으로 판단되며, 여름철 권장환기를 위해서는 2m 정도의 간격으로 설치한 해야만 가능할 것으로 판단되므로 광투과를 저해하지 않으면서 지붕의 개구면적을 확대할 수 있는 방안을 찾아야 할 것으로 생각된다. 실험에 사용한 단동 온실은 인접 동 간격이 1.2m에 불과한 밀집된 단지 내에 위치하고 있어서 측창 주변의 외부 풍속이 최대 0.9m·s-1(평균 0.4m·s-1에 불과하고 풍력에 의한 환기효과를 기대하기가 어려웠다. 환기량과 풍속 및 실내외 온도차와의 관계를 비교 분석해 본 결과 중력환기가 우세함을 확인 할 수 있었다. 본 환기실험 자료를 온실의 환기설계를 위한 열평형모델에 적용하여 증발산계수를 추정해 본 결과 0.39~0.85의 범위(평균 0.62)를 보였고, 다른 연구자들이 제시하는 일반적인 온실의 설계 권장 값과 유사한 경향을 나타냈다. 따라서 토마토 재배 단동 플라스틱 온실의 환기설계에서 증발산계수는 0.6 정도를 사용하면 적당할 것으로 판단된다.
본 연구에서는 양봉사 내부환경을 보다 효율적으로 조절할 수 있는 환기팬 작동방식을 구명하기 위하여 시뮬레이션을 통해 얻어진 환기팬 작동방식에 대한 연 구결과를 양봉사에 직접 적용하여 실험을 실시하였으며, 양봉사 내부의 온도 및 습도변화에 대한 시율레이션과 실험결과를 비교 · 분석하여 양봉사 설계시 양봉사 열환경 해석 프로그램의 적용성을 검토하고, 실험결과를 이용하여 환기팬 작동방식별 양봉사 내부환경의 조절 성능을 분석하였다. 기 개발된 양봉사 열환경 해석 프로그램은 앞으로 양봉사 설계에 적절하게 이용할 수 있을 것으로 판단되었다. 외부기온이 비슷한 조건에서는 환기팬 작동방식 B의 경우가 A의 경우보다 양봉사의 내부온도가 대체로 더 낮았으며, 평균적으로 벌통 내부는 2.8℃, 양봉사 내부는 2.1℃ 더 낮았다. 이것은 Lee 등(1998b)이 제시한 환기팬 작동방식에 따라 양봉사 내부의 승온억제를 최고 2.8℃까지 할 수 있다는 내용을 뒷받침하는 실험결과이다. 환기팬 작동방식 A와 B 모두 꿀벌이 월동하기에 적합한 상대습도 범위 (50~75%) 였으나, 방식 B가 A 보다 양봉사 내부 습도의 최고 및 최저편차가 약 2%, 평균습도가 약 5% 적게 나타나 습도환경조절에 있어 좀 더 안정적인 것으로 판단되었다. 따라서 환기팬 작동방식 B는 A 에 비하여 양봉사 내부환경조절 성능이 더욱 우수하고 효율적인 것으로 판단되었다.
온실에서 환기는 온실내외의 공기를 교환하여 온실내부의 환경을 조절하는 수단으로 활용되고 있으나 조절 목표는 한계가 있기 때문에 보조수단의 역할을 한다. 주년재배용 대규모 온실 설계시 해결해야 할 문제중의 하나가 여름철의 고온장해이며 이는 온실의 자연환기 성능과 밀접한 관계를 가지고 있다. 본 강좌에서는 온실의 자연환기에 관한 기본적인 내용을 요약하여 정리하고, 온실구조가 자연환기 성능에 미치는 영향을 파악하기 위하여 수치해석으로 온실의 필요환기량, 측창과 천창의 면적비와 온실 폭이 자연환기 성능에 미치는 영향을 분석하였다. 온실의 자연환기 성능을 향상시키기 위해서는 주어진 조건하에서 가능한 한 측창과 천창의 면적을 동일하게 설계해야 하고 주년재배용 대규모 온실에서는 폭이 대략 50m이상이 되면 자연환기성능을 기대하기 어렵기 때문에 유의해야 할 것으로 판단된다.