This study evaluated the effectiveness of odor reduction when spraying inside the Bio-curtain (hereinafter referred to as curtain) according to the exhaust fan operating rate. Spraying is a main factor affecting the ability to odor reduction of curtains. The curtain (total area: 37.9m3) was constructed with two layers of light-shielding screens stretched over a rectangular parallelepiped structure installed around an exhaust fan (630 mm) on the side wall of a pig barn. Air samples for odor analysis were collected from inside the pig barn and outside the curtain. The main odorous compounds such as volatile fatty acids, phenols, indoles, and ammonia were measured. The odor reduction effectiveness was evaluated by total odor activity values (TOAVs) summed to the odor activity values of each odorous compounds. Depending on the exhaust fan operating rate, the reduced rate of TOAVs gradually decreased to the range between 15.67% and 68.80%. Because the contact time between the spraying liquid and the air velocity of the exhaust fan becomes shorter (or there is a reduction in liquid to gas flow ratio) as the exhaust fan operating rate increases. The results of this study can be used as basic data for research into spraying conditions to improve the odor reduction effectiveness of curtains.
The distance between livestock facilities and residential spaces is decreasing. Moreover, livestock odor complaints are increasing due to the large-scale and concentrated livestock breading industry. In order to reduce odor from livestock facilities, bio-curtain that are easy to install and inexpensive are commonly used in Korea. However, there is a lack of basic data on design standards and operation manuals for bio-curtains. The installation density of the bio-curtain material is an important factor that affects the odor reduction rate, increment of the load on the ventilation fans, and the structural stability of the curtain. There are limitations on deriving the design conditions of the bio-curtain by only field experiments targeting invisible air. Therefore, aerodynamic simulation such as CFD (computational fluid dynamics) can be used to obtain quantitative data according to various environmental conditions. Bio-curtain is a porous medium with a complex structure, and it is necessary to derive aerodynamic coefficients to analyze it. In this study, the wind speed and pressure difference according to the design density of the bio-curtain were monitored using the experimental chamber. Using the field results, a pressure resistance curve was created for each flow velocity and installation density. The viscosity and resistance coefficient of the bio-curtain were calculated through the derived resistance curve.
Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.