In this research, the concrete breakout strength in tension of cast-in-place anchors (CIP) is experimentally investigated to be used as fundamental data for the seismic fragility analysis of equipment in nuclear power plants. Experimental variables are chosen, such as the embedment depth of the anchor, single/group anchor configurations, diameter of the head plate, and crack width. Monotonic and cyclic loading are applied to all types of specimens. As measured from the experiments, concrete breakout strength in tension is 1.5 to 2 times higher than the expected strengths from concrete capacity design (CCD) method-based model equations. In alignment with the model’s predictions, concrete breakout strength increases with deeper embedment depth, and the strength of group anchors also increases based on the expansion of the projected concrete failure area. This study also explores the effects of head plate diameter and crack width, which are not considered in the model equation. Experimental results show that the diameter of the head plate is not directly correlated to the concrete breakout strength, whereas the crack width is. The presence of cracks, with widths of 0.3 mm and 0.5 mm, leads to reductions of approximately 7% and 17%, respectively, compared to single anchors in non-cracked concrete.
The damage to non-structural elements in buildings has been increasing due to earthquakes. In Korea, post-installed anchors produced overseas have been mainly used for seismic anchorage of non-structural components to structures. Recently, a new cast-in-place concrete insert anchor installed in concrete without drilling has been developed in Korea. In this paper, an experimental study was conducted to evaluate the tensile and shear strengths of the newly developed anchor under monotonic load. The failure modes of the tension specimens were divided into concrete breakout failure and steel failure, and all shear specimens showed steel failure. In both tension and shear, the maximum loads of specimens were greater than the nominal strengths predicted by the concrete design code (KDS 14 20 54). As a result, it is expected that the current code can also be used to calculate the strength of the developed cast-in anchor.
In case of underground construction affected by groundwater, CIP (Cast-In-Place Pile) method is generally used to resolve the geo-hydraulic problem. However, as this method has poor connectivity between piles, an auxiliary method for cut-off is needed in many cases. In this study, a new concept earth retaining wall method (H-CIP) with no auxiliary method, by using surfactant grout (Hi-FA) which improves antiwashout and infiltration ability, is introduced, and its field applicability is evaluated. CIP and H-CIP piles were installed with same ground conditions, and field permeability tests were conducted to verify the performance. As results, newly contrived H-CIP method shows higher antiwashout performance for cut-off than conventional CIP method.
Bond stress between cast-in-place ductile fiber reinforced cementitious composites and CFRP plank were experimentally analyzed. As failure shape, the mixture of failure between CFRP plank and epoxy, and failure between concrete and epoxy was shown. In case of RFCON from the suggested simple bond slip relationship, the maximum average bond stress was 5.39MPa, the initial slope was 104.09MPa/mm, and the total slip length was 0.19mm. PPCON showed the maximum average bond stress of 4.31MPa, the initial slope of 126.67MPa/mm, and the total slip length of 0.26mm, while RFCON+ appeared to have 8.71MPa, 137.69MPa/mm, 0.16mm. PPCON+ had 6.19MPa maximum average bond stress, 121.56MPa/mm initial slope, and 0.34mm total slip length. To comprehend the behavior of composite structure of FRP and concrete, local bond slip relation is necessary, and thus a simple relation is suggested to be easily applied on hybrid composite system
본 연구에서는 국내 원전에서 기기 정착을 위하여 가장 널리 적용되는 직매형 앵커기초를 대상으로 앵커기초의 인장 설계기준에 대한 적정성을 검토하기 위하여 수치해석이 수행되었다. 본 연구에서 수치해석모형에 적용된 파괴기준으로서 콘크리트와 같은 유사 취성재료에는 Microplane모형이, 앵커볼트와 같은 연성재료에는 탄성-완전 소성모형이 적용되었다. 그리고, 균열 발생현상을 모사하기 위하여 분산균열모형을 채택하였다. 개발된 수치해석모형은 다양한 경우의 실증시험결과를 근거로 신뢰성이 검증되었으며, 검증된 수치해석모형과 앵커볼트의 유효매입깊이를 변수로 한 다양한 경우에 대한 수치해석을 통하여 직매형 앵커기초의 인장설계기준으로서 적용이 가능한 ACI 349 Code와 CEB-FIP Code가 평가되었고, 그 보수성이 확인되었다.
The damage caused by the earthquake is not only the structural damage, but also the damage caused by the functional damage of the non - structural element. However, the criteria for seismic design for non - structural elements such as electrical panels are insufficient compared to those for seismic design for structural damage. In this study, the performance of the anchor bolt connecting between electric panel and concrete slabs installed in a power plant according to the occurrence of crack was investigated by experiment.
기존의 LB-DECK는 레티스바와 현장에서 배근되는 철근과의 간섭이 시공성 등을 저하시키는 문제점이 지적되고 있었다. HB-DECK는 레티스바의 형태를 단순화하고, 방향을 주철근 방향에서 배력근 방향으로 전환하였으며 강성을 증가시키기 위해 하면에 리브를 설치하였다. 본 연구에서는 HB-DECK가 프리캐스트 콘크리트 슬래브로써 성능을 발휘할 수 있는지를 검증하고자 하였다. 이를 위해 도로교설계기준(2015)에 의한 구조검증과 HB-DECK와 현장타설 콘크리트와의 합성거동 분석을 위해 정적재하시험을 수행하였다. 범용구조해석 프로그램인 MIDAS FEA를 이용하여 3차원 유한요소해석을 수행하였으며, 해석결과와 실험결과를 비교분석하였다. 그 결과, HB-DECK는 현장타설 콘크리트와 완전한 합성거동을 하는 것으로 나타났으며, 도로교설계기준(2015)에서 요구하는 구조성능을 만족하는 것으로 나타났다.
최근 철도의 고속화 및 중량화에 따라 주행 시 보다 높은 안전성을 확보할 수 있으며, 유지보수 비용을 절감할 수 있는 콘크리트 궤도의 부설이 증가하고 있다. 일반적으로 콘크리트 궤도의 대표적인 단점으로는 자갈 궤도에 비하여 탄성이 부족하여 소음 및 진동에 불리한 점이 있으나, 이외에도 콘크리트 표면에 발생할 수 있는 균열 등의 열화요소에 대한 적절한 관리가 이뤄지지 않을 경우 열차의 안전에 큰 위협 요소가 되며 막대한 교체 비용을 초래할 수 있다. 이 논문에서는 현재 경부 및 호남 고속선에 부설된 현장타설형 콘크리트 궤도 도상에 대한 균열 해석을 통하여 도상에 배근되는 철근의 역할을 규명하고, 보다 시공성을 제고할 수 있으며 균열 발생 가능성을 저감할 수 있는 시공 방안을 제시하였다. 콘크리트 궤도에 대한 균열 해석은 ABAQUS를 사용하여 수행하였다.
최근에 상용 FRP 판(plank)을 콘크리트 구조물의 영구 거푸집 및 보강재로 이용하기 위한 연구가 진행되고 있다. FRP 판과 타설 콘크리트가 합성효과를 발휘하기 위해서는 두 재료간의 부착이 중요한 요인 중의 하나이다. 이러한 부착을 확보하기 위하여 FRP 판에 모래를 일반적으로 건설현장에서 많이 사용하는 에폭시를 이용하여 부착하였다. FRP 판과 콘크리트 합성구조의 구조적 거동을 이해하기 위해서는 FRP판과 타설 콘크리트 사이의 정량적인 국부 부착모델이 필요하다. 본 연구에서는 이와 같은 합성구조 시스템에 간단히 적용할 수 있는 단순 부착모델을 제안한다.