검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We report the structural characterization and electric heating performance of carbon thin films (CTFs), which were prepared from negative-type SU-8 photoresist by deep UV exposure and following carbonization. The prepared CTFs were found to have pseudo-graphitic carbon structures containing partially graphite domains in the amorphous carbon matrix. The CTFs showed a very smooth surface morphology with a roughness of 0.42 nm. The 107 nm-thick CTFs exhibited an excellent electric heating performance by attaining a high maximal temperature of 207 °C and a rapid heating rate of 13.2 °C/s at an applied voltage of 30 V. Therefore, the CTFs prepared in this study can be applied as electrode materials for high-performance electric heaters.
        4,000원
        2.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 서로 다른 열전달 특성을 가진 탄소섬유 전기발열체와 경유온풍난방기가 온실 내부의 온습도, 에너지소비, 작물생육 등에 미치는 영향을 분석하기 위해 오이 재배 단동온실에 대한 난방 비교시험을 수행하였다. 전기발열체 온실에서 난방용량이 온실 환경과 난방기 운전에 미치는 영향을 분석하기 위해 온실에 6, 9, 16kW의 전력을 각각 공급한 결과 전기발열체 ON-OFF 주기는 각각 9, 11, 15회로 비례하여 증가하였으며 온실 내부 평균온도는 각각 15.2, 15.3, 15.6oC, 평균상대습도는 84, 81, 76%로 나타나 난방 용량이 클수록 온실내부 온도는 높고, 상대습도는 낮게 나타났다. 또한 6, 9kW 가동 시 하부온도가 상부보다 0.1oC 높았으며 16kW 가동 시는 상부 평균온도가 하부보다 0.2oC 높았다. 전기발 열체와 경유온풍난방기의 비교 시험에서는 난방 시 온실 상부와 하부의 온도차가 전기발열체 온실이 0.1~0.2oC로 경유온풍난방기 온실의 0.5~0.6oC보다 작았으며, 온실 상류와 하류의 온도차는 전기발열체 온실이 0~0.1oC로 경 유온풍난방기 온실의 1.3~1.4oC보다 작아 정밀한 온도관리가 가능하였다. 난방기간 동안 사용한 에너지사용량은 경유온풍난방기 온실이 경유 867L를, 전기발열체 온실이 전력량 8,959kWh를 사용하였으며, 난방비용은 각각 607 천원과 403천원이 소요되어 전기발열체 온실에서 약 34%의 비용절감 효과가 있었다. 전기발열체 온실의 경우 상대적으로 군락 상하부의 환경관리가 균일하여 초장을 비롯한 전반적 생육상황이 경유온풍난방기 온실보다 좋았으나 통계적으로 유의한 차이는 없었으며, 수확량 역시 전기발열체 온실의 작물군락 하부 온도가 경유온풍 난방기 온실보다 1.3oC 더 높게 관리되어 4.3% 증수효과가 있었으나 통계적으로 유의한 차이는 없었다. 원예 시설의 최적 난방 관리를 위해서는 각 난방기의 열전달 특성에 기초하여 난방기 용량, 배치, 열분배 방법에 대한 설계가 요구되며, 전열선 형태의 난방기 역시 작물형상 및 재배방법을 고려하여 전열선의 개수, 위치, 방열 온도 등에 대한 설계가 필요한 것으로 판단되었다.
        4,000원
        3.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature (0℃) to the reference temperature (5~8℃) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.
        4,000원
        5.
        2010.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경상대학교 교내에 설치되어 있는 1-2W형 온실을 대상으로 전기 방열기를 이용하여 국화 재배온실의 난방효과를 검토한 결과는 다음과 같다. 실험기간동안 최고, 평균 및 최저 외기온은 각각 -3.8~21.3℃, -5.2~16.1℃ 및 -12.5~14.4℃ 정도의 범위로 나타났으며, 온실 내외의 평균상대습도 각각 43.5~98.6% 및 35.2~100%로 나타났다. 12월 중순부터 2월 상순까지 최저 외기온은 대략 -5.0~-10.0℃ 전후로 나타나 진주기상대의 최근 자료와 비교하면 상대적으로 최저기온이 낮게 나타나는 경향이 있었다. 야간의 경우, 방열기 직하부의 엽온이 방열기 중간 지점에서 측정한 엽온 보다 크게 2~3℃정도 높게 나타나거나 또 는 미미하지만 약간 높게 나타나는 경향이 있었다. 근권부의 경우, 직하부나 중간 지점에서의 온도 차이 는 거의 없는 것으로 나타났고, 근권부의 최고온도와 기타 최고 온도의 발생 시점을 보면, 약 2시간정도 의 지체현상이 있음을 알 수 있었다. 그리고 실험기간동안 난방에 소요된 총 소비전력량, 공급에너지 및 총 난방비는 각각 2,800kWh, 2,408,000kcal 및 112,000won 정도였다. 화석연료인 경유로 난방할 경우, 총 난방비는 224,500won 정도였다. 방열기를 이용하여 난방할 경우, 난방비를 약 50% 정도 줄일 수 있을 것 으로 판단되었다.
        4,000원
        7.
        2006.04 구독 인증기관·개인회원 무료
        We present a systematic study of the heating and pre-sintering behavior of porous copper powder metal compacts. We employ a TE102 single mode microwave system to position the samples in the separated electric field (E) or magnetic field (H) anti-node of the cavity. We observe significant differences in the heating, pre-sintering, and microstructure evolution of the samples due to the individual fields. We note that sample history (whether heated first in the E-field or H-field) greatly effects a difference in heating trends and subsequent heating behavior and does not appear to be solely a thermal process.