검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we learned about the effects of indoor radon concentration reduction associated with the operation of a mechanical ventilation system at an apartment house. The experimental parameters were mainly the indoor radon level and air change rate, which were controlled by the amount of emissions released and fan motor speed. Even at the high level of radon diffused in an apartment house, indoor radon concentrations converged to the Korean national guideline level within 3 to 4 hours when the air was ventilated at 0.5 ACH and 0.7 ACH. In the case of 0.3 ACH, however, where the degree of ventilation was insufficient compared to the legal air change rate, the high concentration indoor radon could not be sufficiently removed even if the mechanical ventilation system was operated for more than 14 hours continuously. When the indoor radon level was high, the reduction rate was 34.3% for 0.3 ACH, 70.4% for 0.5 ACH, and 69.7% for 0.7 ACH at 6 hours-operation, while at the medium-level, indoor radon can be reduced by 46.2% (0.3 ACH) to 73.2% (0.7 ACH). Depending on the indoor concentration range, it may be required to secure a ventilation rate of 0.5 ACH or more at all times. In addition, in apartment houses with excellent airtight performance, even if indoor radon is at a level similar to the national guideline, it is difficult to expect a reduction in the concentration due to natural decay. Therefore, it is desirable to lower the indoor concentrations as much as possible.
        4,000원
        2.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조와 사육환경이 동일한 3개의 돈방(room A~C)에서 48일 동안 비육돈의 암모니아 농도 및 환기량을 모니터링하여 배출계수를 산정하였다. 실험 결과, 온도 22.5℃, 습도 53.9% 환경에서 평균 암모니아 순발생 농도 5.93 ppm, 환기량 23.7 m3/h·pig로 나타났다. 일별 상관관계 분석결과, 암모니아 농도는 온도와 음의 상관관계(R2: -0.65 ~ -0.53)를 가지는 것으로 나타났으며, 환기량은 암모니아 농도에 거의 영향을 미치지 않는 것으로 나타났다. 암모니아 농도는 이른 오전을 기점으로 서서히 증가 경향을 보이다가 12~13시경 최댓값에 도달하였고, 상호 상관도가 높은 온도, 습도, 환기량의 경우 14~15시에 최댓값을 갖는 것으로 분석되었다. 시간별 데이터 상관관계 분석결과, 암모니아 배출량에 영향을 미치는 요소는 암모니아 농도(R2=0.71)와 환기량(R2=0.61)으로 이 중, 암모니아 농도가 더 상관성이 높은 것으로 분석되었다. 암모니아 배출계수는 2.28 g/d·pig로 분석되었다.
        4,000원
        3.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The characteristics of ammonia during the growing period of pigs in a facility with a mechanical ventilation system were analyzed, and the emission factor was calculated. Real-time ammonia concentration was measured using photoacoustic spectroscopy equipment, and a ventilation measuring device was fabricated to measure the amount of air vented from an exhaust fan according to the operation rate. All data were collected as one-hour averages. The mean ammonia concentration, indoor temperature, and ventilation rate was 1.44~2.08 ppm, 25.5~26.4oC, and 24~32 m3/h per pig, respectively. Both concentration and ventilation rate are important factors in terms of emission management, but correlation analysis shows that the impact of concentration is higher than that of ventilation. Using ammonia concentration and ventilation data, the ammonia emissions per pig were calculated by considering the number of pigs (0.25~1.74 g/day·pig). The final ammonia emission factor yielded a value of 0.81 g/day·pig.
        4,000원
        4.
        2015.03 구독 인증기관 무료, 개인회원 유료
        In this study, a scaled model chamber was built to investigate ventilation characteristics of the pump room in tanker and to look into stationary areas of flow field. Experimental study was performed for three kinds of Reynolds number based on the inward velocity and height of inlet port in model by visualization equipment with laser apparatus. The flow pattern reveals the large scale counterclockwise forced-vortex rotation from upside louver to lower scupper toward diagonal corner and also found small eddies at bottom layer.
        3,000원
        5.
        2001.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In regulation of IGC code 12.1 mechanical ventilation should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapours and ensure a safe working environment, but in no case should the ventilation system have a capacity of less than 30 changes of air per hour baed upon the total volume of the space. In this study, a scaled mode chamber was constructed to investigate the ventilation characteristics and stagnation area in the hood room of LNG carrier and pump room in tanker. An experimental study was performed on the model by using visualization equipment with a laser apparatus and an image intensifier CCD camera. Twelve different kinds of measuring areas were selected as the experimental condition. Instant simultaneous velocity vectors in the whole fields were measured by a 2-D PIV system A three-dimensional numerical simulation was also carried out for three different Reynolds numbers. Then the CFD predictions were discussed with the experimental results. The results show the spiral L-shape flow that moves from the opening on the left wall diagonally to the upper right part dominates the ventilation structure. The stationary area of hood room in the velcoity distributions was located in the upper left stern part.
        4,000원