검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Microclimate analysis was conducted through actual measurement according to land use status in urban, and CFD analysis was conducted to analyze and predict the microclimate characteristics of urban, and compared and analyzed with the actual measurement results. It was measured in high-rise areas and parks, and the temperature of the park area was 0.4 to 0.6℃ lower, and the relative humidity was 1.0 to 3.0% higher. The correlation coefficient was obtained by comparing the results of the computational fluid analysis with the results of the computational fluid analysis at the actual location located within the CFD analysis area for validation. The seasonal correlation coefficients are all higher than 0.8, so it is judged that they can be applied to microclimate analysis in urban area. The computational fluid analysis was divided into three areas (low-rise, low and high-rise, and high-rise) centered on the A2 point. On average, the low-rise area was 0.1 to 0.4% higher than the high-rise area. In the low and high-rise area and high-rise area, the pith of buildings are wide, so the airflow is smooth, so it is judged that the temperature is relatively low.
        4,000원
        2.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Micro-climate measurements and computational fluid analysis were conducted to use it as basic data for the preservation and management of the old house of Kim Myung-kwan, a traditional building that is National Folk Cultural Property No. 26. As a result of the actual measurement, the temperature and humidity are relatively evenly distributed indoors unlike outdoors, but the temperature and humidity vary depending on the time change and the installation location in the outdoors. It was found that the temperature increases after dawn and the temperature varies depending on the installation position around 14:00–15:00, when the temperature becomes the highest. In particular, the temperature was high at the outdoor measurement point adjacent to the building and the fence. As a result of the computational fluid analysis, the temperature was high in the buildings and fences in the old house or in the area adjacent to the building, and it was about 1℃ higher than the surrounding area. In this area, it is judged that the thickening of wood will occur more severely than in other locations, and special preservation management is required.
        4,000원
        3.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 경남지역 내 소나무 장령림이 안정적으로 생육하고 있는 사찰 소나무림을 대상으로 온도 및 습도의 미기상 변화 특성과 식생분포특성을 비교하여 소나무장령림의 미기후 조절정도를 살펴보고자 하였다. 연구는 국내에서 소나무 장령림 의 안정적 생육지로 알려진 합천 해인사, 부산 범어사, 양산 통도사 및 경주 불국사 일대 소나무림을 대상으로 하였다. 식생분포 현황 분석결과 이들 소나무림은 알려진 바와는 달리 소나무림의 면적비율이 월등히 높지는 않았는데, 통도사 주변을 제외하면 소나무림보다 낙엽활엽수림 및 혼효림의 우점비율이 훨씬 높게 나타나고 있었다. 미기상데이터 측정 결과 통도사는 다른 세 지역과는 달리 미기후 특성이 크게 차이가 있었는데, 다른 세 지역의 경우 온도 및 습도의 일교차가 상대적으로 적은 반면 통도사는 일교차가 크게 나타나는 현상을 보였다. 이는 통도사 주변 숲이 개발지를 제외하면 대부분 소나무림인 반면, 다른 세 지역은 낙엽활엽수림의 우점비율이 높은데 기인하는 것으로 판단된다. 소나무림의 적극적 관리는 온도상승과 공중습 도의 감소에 효과적이지 않은 만큼 현재 양산 통도사 주변 소나무림과 같이 소나무 단순림으로의 적극적인 관리는 오히려 온도와 습도 스트레스 측면에서 부정적 영향이 더욱 큰 것을 확인할 수 있었다. 소나무림의 미기후 완화 효과 증대를 위해서는 숲 관리의 새로운 전환이 필요한 것으로 판단된다.
        4,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The oyster mushroom cultivation house typically has multiple layers of growing shelves that cause the disturbance of air circulation inside the mushroom house. Due to this instability in the internal environment, growth distinction occurs according to the area of the growing shelves. It is known that minimal air circulation around the mushroom cap facilitates the metabolism of mushrooms and improves their quality. For the purpose of this study, a CFD analysis FLUENT R16 has been carried out to improve the internal environment uniformity of the oyster mushroom cultivation house. It is found that installing a section of the working passage towards the ceiling is to maintain the internal environment uniformity of the oyster mushroom cultivation house. When all the environment control equipment – including a unit cooler, an inlet fan, an outlet fan, an air circulation fan, and a humidifier – were operated simultaneously, the reported Root Mean Square (RMS) valuation the growing shelves were as follows: velocity 23.86%, temperature 6.08%, and humidity 2.72%. However, when only a unit cooler and an air circulation fan operated, improved RMS values on the growing shelves were reported as follows: velocity 23.54%, temperature 0.51%, and humidity 0.41%. Therefore, in order to maintain the internal environment uniformity of the mushroom cultivation house, it is essential to reduce the overall operating time of the inlet fan, outlet fan, and humidifier, while simultaneously appropriately manage the internal environment by using a unit cooler and an air circulation fan.
        4,000원
        5.
        2004.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 토지피복현황과 수림의 층위구조 등이 다양한 도시녹지를 대상으로 미기상 조절에 미치는 영향을 정성 및 정량적으로 파악하기 위해 녹지내의 기온 및 습도를 관측하였다. 그 데이터를 바탕으로 녹지내의 토지피복 현황과 그 비율, 녹적량과 기온 및 습도와의 관련성을 회귀분석 등에 의해 해석하였다. 그 결과 고온역은 포장면과 나지 주변에서, 저온역은 수림지 및 수면 주변에서 형성되었다. 또한, 수림(교목+소교목)으로 둘러싸인 수면, 소하천 주변에도 저온을
        4,000원
        6.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        The safety of the future mankind becomes a world issue due to the climate change driven by global warming. It is inevitable to observe everywhere in daily life the impact of climate change. The level of emergency differs between long-term, mid-term, and short-term, which depends on situation. The impact of climate change in daily life is fairly diverse, and therefore multiple research units of different backgrounds often work together on the measuring and forecasting of the impacts. This paper aims to study the potentially useful methods to analyze and forecast the impact on the changes in transport activities of Canadian Inuit. This is part of the research on the climate change’s impact on the Northern Sea Route area. Either natural or man-made change of external environment forces human to adjust their daily life in order to maintain their utility level of life. Individual or individuals’ group react to the external impact, the way of which differ from others. This fact calls a simulation research on the whole set of input-intermediate process-output. Agents representing individuals or certain subpopulation are given a set of rules to react to stimulus and interact with other agents behave in the realm of simulation. This paper provides methodological discussions on how analyzing and forecasting future change in transport activities in response to climate change. The discussion goes around activity-based approaches that are recently popular in urban planning and transportation planning among available simulation approaches. This paper then discusses the implication and future research agenda.
        7.
        2016.10 서비스 종료(열람 제한)
        Background : Ginseng rain cover farming is expanding around Jinan county and Jangsu country of North Jeolla Province. Some farmers doing ginseng rain cover farming have suffered from difficulties due to hot weather damages. However, it is a situation that the study on mitigation techniques for high temperature damage do not exist with ginseng rain cover farming. Methods and Results : The test covering work was firstly done on April 28th for heat block film+90% black light blocking net, blue double sided film, and PE film+75% black light blocking net and when it comes to second treatment, 30% and 40% shading were implemented for heat block film group and blue double sided film group respectively and 75% black light blocking net was installed on PE film+75% shading group. When it comes to micro-climate measurement in rain cover facility, temperature, humidity and light intensity were measured during the growing period of ginseng. The results are as follows. Regarding the light transmittance (per PAR, 10 am in clear day) in facility with 1st covering, light block film covered group (LBF), blue double sided film group (BDF) and PE film group have 12.9±1.8%, has 11.6±1.0% and 27.1±1.1% respectively and after 2nd covering, in LBF groups, 30% blocking, 40% blcoking and no blocking have 10.6±1.3%, 8.2±0.9% and 12.9±1.8% and in BDF groups, 30% blocking, 40% blcoking and no blocking have 9.4±0.8%, 7.9±0.7% and 11.6±1.0 respectively and PE film group has 10.6±0.7%. Relative humidity also showed the same trend as temperature. The average monthly amount of light and maximum light intensity were lower in 30% and 40% light blocking groups of LBF and BDF and a little higher in no light blocking group compared to PE film group. The degree of high temperature damage was 1 in no LBF of BDF, but no LBF of LBF was so bad like 3. However, there was no high temperature damage in the test groups of blocking films or BDF with 30% and 40% light blocked light screens. Regarding root weight, all secondly treated groups of LBF group and BDF group were lighter compared to 4.36g of PE film group and especially, prism sheetof no light blocking group has 2.5g and BDF of of no light blocking group has 3.21g. 30 % and 40% light blocking groups of LBF group and BDF group were light with 3.20~4.07g. Conclusion : Regarding the analysis result on micro-climate in facility with different cover materials for 2 years old ginseng in ginseng rain cover farming of Gyeonggi Province, the covering method suitable for high temperature damage mitigation in ginseng rain cover farming was that 1st covering was done by PE film+75% black light blocking net and then 75% black light blocking net is additionally covered at a time when outside temperatures reaches 30℃.
        8.
        2004.12 KCI 등재 서비스 종료(열람 제한)
        Rapid progress in urbanization has resulted in a change of the micro climate, especially in the urban area. In order to investigate the phenomenon of the heat island in the residential micro climate, a field survey was carried out by 4 sets of the residential type in Jeonju under typical winter synoptic condition. As analytic methode, it is used the comparison on the relation of the Land-to-Coverage Rate to Heat Island and Oxygen Concentration. And as a key question it is asked how stable characteristics of the micro climate will result from the survey of the Heat Island and the Oxygen Concentration, used as indicator. To ensure the trustworthy result of research, it is calculated the critical influence of the wind velocity and the Land-to-Covearage Rate. As a result of comparative analysis, it could be confirmed that the local temperatures in all sets of the residential type were higher than the average temperature in Jeonju. But the housing type A "exclusive use for housing zone" has relativly the most stable and best living condition. On the contrary the residential type B and D has the worst toward the oxygen concentration in the time zone 9-12 a.m., which didn't reach the minimum of the oxygen concentration 20.5%. It means that the higer the development and population density is, the worse is the situation of the Quality of Life in the residential types in accordance with the heat island and oxygon concentration.
        9.
        2003.05 KCI 등재 서비스 종료(열람 제한)
        We developed a numerical model that considered the influences on the thermal environment of vegetation, water surfaces and buildings to predict micro climatic changes in a few km2 scales; and applied this model to the Mino residential development region in Osaka Prefecture by using a nested technique. The calculated temperatures and winds in the residential development region reasonably agreed with the observed ones. We then investigated the influences on the thermal environment of the construction of a dam, the change of the green coverage rate. The results obtained from the numerical simulations were qualitatively reasonable.