검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Daechung Reservoir has been suffering from severe cyanobacterial blooming periodically due to the water pollutants from the watershed, especially nutrients from nonpoint sources. As a countermeasure, an artificial wetland was constructed to mitigate the pollutant load from the watershed by utilizing the vegetation. We investigated the water quality of the influent and outflow of the wetland during years 2014~2020 to evaluate the performance of pollutant removal through the wetland. Major pollutants (e.g. BOD, COD, SS, T-N, and T-P) were largely reduced during the retention in the wetland while nutrients removal was more efficient than that of organic matters. Pollutant removal efficiency for different inflow concentrations was also investigated to estimate the wetland’s capability as a way of managing nonpoint sources. The efficiency of water treatment was significantly higher when inflow concentrations were above 75th percentile for all pollutant, implying the wetland can be applied to the pre-treatment of high pollution load including initial rainfall runoff. Furthermore, the yearly variation of removal efficiency for seven years was analyzed to better understand long-term trends in water treatment of the wetland. The annual treatment efficiency of T-P was very high in the early stages of vegetation growth with high concentration of inflow water. However, it was confirmed that the concentration of inflow water decreased, vegetation stabilized, and the treatment efficiency gradually decreased as the soil was saturated. The findings of the study suggest that artificial wetlands can be an effective method for controlling harmful algal blooms by alleviating pollutant load from the tributaries of Daechung Reservoir.
        4,500원
        2.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to investigate the runoff characteristics of nonpoint source pollutants in the Lake Doam watershed, water quality and flow rate were monitored for 38-rainfall events from 2009 to 2016. The EMC values of SS, COD, TN and TP were in the range of 33~2,169, 3.5~56.9, 0.09~7.65 and 0.06~2.21 mg L-¹, respectively. As a result of analyzing the effect of rainfall factor on the nonpoint source pollutant load, EMCs of SS, COD and TP showed a statistically significant correlation with rainfall (RA) (p<0.01) and SS showed highly significant correlation with maximum rainfall intensity (MRI, R=0.48). The load ranges of SS, COD, TN and TP were 10.4~11,984.6, 1.1~724.4, 0.6~51.6 and 0.03~22.85 ton event-¹, respectively, showing large variation depending on the characteristics of rainfall events. The effect of rainfall on the load was analyzed. SS, COD and TP showed a positive correlation, but TN did not show any significant correlation. The annual load of SS was the highest with 88,645 tons year-¹ in 2011 when rainfall was the highest with 1,669 mm. The result of impact analysis of nonpoint source pollution reduction project and land-use change on runoff load showed that pollutant load significantly reduced from 2009 to 2014 but SS and TP loads were increased from 2014 to 2016 due to increase in construction area. Therefore, we suggested that nonpoint source pollution abatement plan should be continued to reduce the soil loss and pollutants during rainfall, and countermeasures to reduce nonpoint source pollution due to construction need to be established.
        4,500원
        3.
        2015.02 구독 인증기관 무료, 개인회원 유료
        Urban areas (residential, commercial, transportation), each of the points during the same rainfall in the same area, this study was evaluated by a survey to find out the basic data and the characteristics of non-point pollution on local characteristics was performed. To evaluate and compare a non-point source pollution concentrations. The conclusion of this study was to know the influence of non-point pollutants in initial rainfall. There was a difference during the same point was compared. The pollution levels were differences in the point-specific characteristics, the same point compared by rainfall when rainfall is low, the contaminant concentrations were high. Finally, when compared to the number of rainy days. The shorter the number of rainy days, the non-point pollutants were high.
        4,000원
        4.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        도로에서의 강우유출수 내 포함된 오염물은 주요한 비점오염원으로 간주되고 있으며 비점오염물질 저감을 위하여 많은 대책이 적용되고 있다. 도로청소에 의한 방법 또한 오염물의 강우유출에 의한 배출양을 감소시킬 수 있는 대책 중의 하나로 인식되는 추세에 있다. 본 연구에서는 도로청소 시 수거된 토사입자들의 특성을 파악하고 퇴적토사에 함유된 오염물질의 농도를 분석하였다. 분석결과를 바탕으로 하여 도로 구간별로 도로청소에 의하여 저감할 수 있는 오염물의 양을 평가하였다. 도로청소를 통하여 수거된 퇴적토사는 모래질로 분석되었으며 세립토 비중은 낮은 결과를 보였다. 퇴적토사 내 오염물의 양은 토양환경기준을 초과하지 않았으나 청소작업시 물을 살수함으로써 토사에 포함된 오염물이 세척되어 침출수로 미리 배출되는 것에 기인한다고 판단된다. 두 도로구역에 대하여 오염물 농도, 발생 퇴적토사량, 오염물 원단위를 적용하여 저감할 수 있는 오염물 양을 평가한 결과, ○○지역에 대하여 TSS 31.4% 및 △△지역에서는 TSS 7.7%의 TSS 저감량이 도출되었다. 중금속과 같은 타 오염물의 경우 훨씬 낮은 저감량이 평가되었으나 이는 물의 살수로 인하여 퇴적토사 내 오염물이 침출수로 배출된 것에 기인한다고 판단된다. 보다 정확하게 도로청소에 의하여 저감할 수 있는 오염물의 양을 산정하기 위하여 보다 자세하고 체계적인 연구가 필요하다고 판단된다.
        4,000원
        5.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to analyse the runoff characteristics of non-point pollution sources in an urban watershed and determine the effectiveness of newly installed riverwater treatment system to reduce water pollution caused by storm runoff in the urban watershed. The results of this study showed that the levels of BOD5 and suspended solid were highly influenced by first-flush effect and the pollutant load of those two parameters were also very high in the urban watershed. Meanwhile, the effectiveness of riverwater treatment system to reduce the levels of BOD5 and suspended solid was relatively high, but those to reduce the levels of T-N and T-P was low, which needs some additional unit treatment process such as filtration and coagulation. Nonetheless, the riverwater treatment system tested was relatively simple in installation and operation, effective in removing many water pollutants and, most importantly, does not require much space as other treatment systems, so it could be an attractive alternative option to reduce riverwater pollution caused by storm runoff in urban watersheds.
        6.
        2015.02 서비스 종료(열람 제한)
        본 연구는 강우 시 발생하는 비점오염물질 중 인과 총 부유성 고형물 분석을 통해 혼합 토지이용에 따른 비점오염 배출 특성을 비교분석하였다. 경기도 용인시 금학천 유역내의 도시지역, 농업우세지역, 혼합토지이용지역, 택지개발지역을 대표하는 총 4개의 소유역 말단에서 강우유출수를 모니터링 하였다. 연구 결과 불투수층이 많은 도시지역은 강우초기에 초기유출현상이 뚜렷하게 발생되었고 다른 지역에 비해 용존성 인의 비가 약 40%정도 높았다. 농업우세지역과 혼합토지이용지역, 택지개발지역은 대부분 인이 고형물에 부착되어 배출되는 입자성 인의 형태를 보였으며, 도시지역과 달리 첨두유량이 발생하는 강우 중기에 가장 높은 농도의 오염물질(TP 및 TSS)이 배출되었다. 모든 모니터링 지점에서 TSS와 TP 농도간 높은 상관성을 나타내고 있어 TP의 배출 제어를 위해서는 TSS의 적절한 제어가 매우 중요함을 알 수 있었다. 특히 택지개발지의 경우 타 토지이용지역에 비해 다량의 토사침식에 의하여 높은 TP 배출부하가 야기될 수도 있음을 예상할 수 있었다.
        7.
        2014.02 서비스 종료(열람 제한)
        최근 수계에 심각한 악영향을 미치는 비점오염원에 대한 정부의 관심이 대두되고 있다. 비점오염물질은 배출경로가 불명확하며, 배출량 또한 측정하기가 어려워 처리하기 또한 곤란하다. 이러한 비점오염물질 제거를 위하여 비점오염저감시설을 개발 및 설치하고 있다. 하지만 비점오염저감시설 설치 시 대상유역에 대한 연구가 미비하여 명확한 저감효율을 판단하기가 어렵다. 본 연구의 목적은 비점오염물질에 따른 저감시설의 효율을 파악함에 있다. 2년간 총 8회의 강우 모니터링을 통하여 경기도 용인시 경안천 유역에 설치 된 비점오염저감시설 중 식생형 시설인 식생여과대의 저감 효율을 ER(Efficiency Ratio) 방법을 이용하여 산정하였다. 모든 시료는 BOD, COD, TN, TP 항목에대해 수질오염공정시험법에 의거하여 분석하였다. 2012년에서의 저감효율은 각각 36%, 37%, 55%, 44%, 2013년에는 63%, 56%, 48%, 67%로 나타났다. 2년간 각 항목별 저감효율 평균값은 50%, 46%, 52% 56%로 영양염류의 제거효율이 유기물의 제거효율보다 높은 수치를 보였다. 결과적으로 경안천유역 비점오염저감시설 중 식생여과대는 영양염류의 제거에 효율적이며, 저감기능 향상을 위해 지속적인 관리와 연구가 필요하다.
        8.
        2012.02 서비스 종료(열람 제한)
        도시화에 따른 불투수 면적의 증가는 개발이전에 비해 더 많은 강우 유출 및 수질악화를 초래하여 적절한 관리방안에 대한 관심이 높아지고 있다. 이에 대한 대안으로써 대두되어진 최적화관리기법(Best Management Practices, BMP)은 이러한 비점오염물질과 강우유출수를 저감하기 위한 방안으로 국내·외에서 많은 연구가 진행되고 있다. BMP 적용을 통한 목표 저감효과를 달성하기 위해서는 BMP별 성능을 비교분석하고 대상유역에 적합한 BMP를 선정하여 설계해야 한다. 현재 이와 관련한 모니터링 연구가 활발히 진행 중에 있으나 유역별로 기후와 지형조건이 상이하고, 미계측 유역의 경우 BMP 성능 예측에 한계가 있다. 이를 극복하기 위해서는 모니터링 연구와 더불어 대상유역의 기상조건과 지형 조건을 고려한 BMP 모형화 기법을 이용한 BMP 별 성능을 분석하는 방법이 필요하다. 본 연구에서는 국내·외에서 강우유출수의 모의에 많이 이용되고 있는 SWMM(Storm Water Management Model) 모형을 이용하여 충청남도 대천항 주차장을 대상으로 BMP 성능 모의를 실시하였다. 모형의 적용성 평가를 위해 국제 우수 BMP Database에 수록되어 있는 사례의 결과와 식생저류지(bioretention) 및 투수성 포장(porous pavement)의 가상설치 시 예측되는 수문 및 수질 저감효과를 비교하였으며, 유출 및 수질 항목별 평균저감율 편차 범위가 -5.8∼+9.6%로 높은 적용성을 보였다. 향후 BMP 설계 및 저감효과 산정에 본 연구에서 제시한 BMP 모의 방법론의 활용이 가능할 것으로 판단된다.
        9.
        2011.03 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban and rural zones in sangju area. The monitoring was conducted with seven events for ten months and Event mean Concentration(EMC) and First Flush Effect(FFE) of SS and BOD were calculated on the result of the water quality parameters. During rainfall event, the peak concentrations of SS and BOD were observed after 3∼4 hours of rainfall in rural areas. Whereas, the peak concentrations occurred within 1∼2 hours after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in urban areas. The cumulative load curves for NPS pollutants showed above the 45° straight line, indicating that fist flush effect occurred in urban areas. The mean SS EMC values of rural areas ranged from 0.9∼3.3mg/L, it was higher value when compare to urban areas. While the mean BOD values of urban areas were shown the highest values.
        10.
        2010.07 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban area in boeun area, Chungbuk Province. The monitoring site covering the watershed of 2.11 km 2 contains about 40.3 % of total watershed with the urban area. The monitoring was conducted with six events for five months and Event Mean Concentration(EMC) and Site Mean Concentration(SMC) of SS, BOD, CODMn, T-N, T-P were calculated on the result of the water quality parameters. As a result of the comparion between Arithmetic Mean Concentration and Event Mean Concentration, it showed that over all Event Mean Concentration was higher than Arithmetic Mean Concentration. And it showed that SS, BOD, T-P featured the first-flushing effect, showing relatively high concentration in early-stage storm event.