검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        2.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해상풍력발전의 건설이 여러 가지 환경 및 가설공법 등의 설치환경 등의 원인에 의하여 건설지점이 천해에서 심해로 이동하는 경향을 나타내고 있다. 이러한 경향 속에 해상풍력발전 지지구조물의 심해화에 따른 지지구조물에 대한 연구는 중요성이 더욱 증대될 것으로 판단된다. 본 연구에서는 기존의 Jacket 구조물에 대하여 Precast Concrete Block 및 Suction pile을 적용한 Jacket 구조물을 제안하고 이에 대하여 구조해석 및 안전성 평가를 실시하였다. 또한 제안된 구조물에 동조액체감쇠기를 적용하여 구조물 진동성능 향상을 도모하고자 하였다. 연구결과, 제안된 신형식 Jacket 구조물은 충분한 안전성을 가지고 있는 것으로 평가되었으며, 동조액체감쇠기를 적용하였을 경우, 약 5%의 진동저감 효과가 있는 것으로 검토되었다.
        4,000원
        3.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 일반 철골구조물에서 사용되는 구조용 프리캐스트 콘크리트 외부벽판과 연결부재로 인하여 건물 전체의 내진성능을 조사하였고, 벽판의 높이 변화에 따른 건물 전체의 횡방향 강성 변화량을 파악하였다. 외부벽판과 연결부재를 구조 부재로 간주할 경우 수동형 제진장치와 같이 지진에너지를 소산할 뿐 아니라 추가로 전체 건물의 횡방향 강성을 제공하는 것을 확인하였다. 이력거동 성능을 가진 연결부재를 비선형 유한요소해석 프로그램인 ABAQUS를 이용하여 조사한 결과, 건물의 내진성능 향상에 연결부재가 가장 중요한 역할을 하는 것으로 확인되었다.
        4,000원
        4.
        2017.04 서비스 종료(열람 제한)
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. The experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        5.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. The experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        6.
        2015.10 서비스 종료(열람 제한)
        Based on the study of rapid construction method for concrete tower for offshore wind farms, it was found that the precast concrete segment was effective to achieve short term construction on bad weather condition. Also 20m length of segment was selected for tower installation to use same crane carrying nacelle.