In NPP (nuclear power plant), boric acid is used as a neutron absorbent. So radioactive boric acid waste are generated from various waste streams such as discharge or leakage of reactor coolant water, floor drains, drainage of equipment for operation or maintenance, reactor letdown flows and etc. Depending on KHNP, 20,015 drum (200 L drum) of concentrated boric acid waste were stored in KOREA NPP until 2019. In previous study, our group suggested the waste upcycling process synthesizing B4C neutron absorber using boric acid waste and activated carbon waste to innovatively reduce radioactive wastes. Radioactive activated carbon waste was utilized in off gas treatment system of NPP to capture nuclide such as I-131, C-14 and H-3. Activated carbon waste is treated as low-level radioactive waste and pre-treatment system for removing nuclide from the activated carbon waste is needed to use B4C up-cycling process. In this study, microwave treatment system is suggested to treat the activated carbon waste. Activated carbon waste was exposed to microwave for a few minutes and temperature of the waste was dramatically increased over 400°C. Nuclide in the activated carbon waste were selectively removed from the waste without massive production of secondary off gas waste.
In NPP (nuclear power plant), boric acid is used as a neutron absorbent. So radioactive boric acid waste are generated from various waste streams such as discharge or leakage of reactor coolant water, floor drains, drainage of equipment for operation or maintenance, reactor letdown flows and etc. Depending on KHNP, 20,015 drum (200 L drum) of concentrated boric acid waste were stored in KOREA NPP until 2019. In previous study, our group suggested the waste up-cycling process synthesizing B4C neutron absorber using boric acid waste and activated carbon waste to innovatively reduce radioactive wastes. Radioactive activated carbon waste was utilized in off gas treatment system of NPP to capture nuclide such as I-131, C-14 and H-3. Activated carbon waste is treated as low-level radioactive waste and pre-treatment system for removing nuclide from the activated carbon waste is needed to use B4C up-cycling process. In this study, microwave treatment system is suggested to treat the activated carbon waste. Activated carbon waste was exposed to microwave for a few minutes and temperature of the waste was dramatically increased over 400°C. Nuclide in the activated carbon waste were selectively removed from the waste without massive production of secondary off gas waste.
억새와 같은 초본계 바이오매스로부터 cellulose, hemicellulose, lignin 등 주요성분을 추출하기 위해서는 알칼리 전처리가 효율적이며, 본 연구에서는 수산화칼륨(KOH)을 이용한 전처리 조건을 최적화하였다. 전처리 변수의 최적화는 반응표면분석법(RSM)을 적용하였다. RSM의 변수는 3개였으며, 변수범위는 각각 KOH 0.2∼0.8M, 반응온도 110∼190℃ 및 반응시간 10∼90min 이었다. 억새의 알칼리 전처리를 위한 최적조건은 KOH 농도 0.47M, 반응온도 134℃ 및 반응시간 65min 이었다. 최적 전 처리 조건에 따라 전처리를 수행한 후 고형물의 cellulose 함량은 66.1±1.1% 이었으며, hemicellulose 및 lignin 함량은 각각 26.4±0.4%, 3.7±0.1% 이었다. RMS 모델식에 따라 계산된 예측값은 실제값 대비 95% 범위 내에서 유효하였다. 최종적으로 전처리물을 동시당화발효를 통해 검증한 결과 에탄올 생산 수율은 96% 이었다.
In this study, various physical cleaning methods such as physical washing and osmotic backwash, were conducted to understand membrane fouling properties by employing real secondary wastewater effluent (SWWE). In addition, microfiltration (MF) and ultrafiltration (UF) pretreatments were compared to maximize removal of organic matter and to control membrane fouling efficiently. Organic foulants deposited on the active layer of FO membrane were observed by fouling behavior test. The relationship between concentrations of natural organic matter and membrane fouling was also investigated from the bench-scale FO tests.
저압 침지식 멤브레인을 이용한 해수 담수화 전처리에 있어서 유기 파울링은 막간 압력 증가로 인한 화학 세정 횟 수의 증가 및 에너지 소비 증가 등 멤브레인 운전시 문제점들을 야기한다. 조류대응 해수전처리에서 조류가 배출하는 extracellular polymeric substances의 대표물질인 sodium alginate를 이용하여 침지식 여과에서 파울링 현상을 관찰하였다. 공기 폭기가 적용되지 않은 경우 순수한 aglinate 파울링은 농도가 증가하면서 증가하였다. 그러나 공기 폭기를 적용해 준 경우 alginate 파울링 감소는 매우 효과적이었다. 공기 폭기가 없는 경우 칼슘 농도의 증가에 따라 alginate 파울링은 감소하였다. 동 일 조건에서 공기 폭기 시 높은 alginate 파울링 감소효과를 나타내었으나 NaCl 농도를 증가시킨 경우 칼슘 농도의 증가에 따 라 파울링 제어를 위한 공기 폭기 효과는 감소하였다. 해수와 유사한 높은 NaCl과 칼슘 농도에서 고농도 sodium alginate의 경우 공기 폭기량 증가를 통해 초기 파울링을 감소시킬 수 있었으나 시간의 경과에 따라 상대적으로 낮은 폭기량에서의 파울 링 감소 효과와 큰 차이는 없었다.
CT 조영검사 예약환자의 원활한 검사 진행과 조영검사로 인한 부작용을 줄일 수 있는 전처치 프로세스 시스템을 개발 및 적용하여 CT 조영검사 예약환자의 검사 만족도를 높이고자 하였다. 2014년 1월부터 201 4년 2월까지 CT 조영검사를 예약하여 추적검사를 시행했던 2,846명의 환자들 중 예약시간에 검사를 시행 하지 못하고 지연된 214명의 환자들을 대상으로 지연사유를 분석한 후 전처치 프로세스 시스템을 구상 및 개발하여 2015년 1월부터 2015년 2월까지 전처치 프로세스 시스템을 이용하여 전처치가 필요한 644명을 대상으로 SMS 전송 시행율, SMS 전송내역, 예약시간 준수율, 예약시간 지연 사유, 예약 시간보다 지연된 시간 등을 분석하였다. 2014년 1~2월 외래 CT 조영검사 예약환자는 2,846명이었고, 그 중 예약시간에 검사 를 시행하지 못한 환자는 214건으로, 약 7.52%의 비중을 차지하고 있었다. 예약시간보다 지연된 세부적인 사례는 creatinine 미확인이 98건(46%), creatinine 1.3 이상이 40건(19%), 과거조영제부작용이 34건(16%), 금 식 등 전처치 미흡이 25건(11%), 메트포민제제 당뇨약 복용이 4건(2%), 기타 이유가 13건(6%)으로 나타났 으며, 평균 지연시간은 creatinine 미확인이 120분, creatinine 1.3이상이 30분, 과거조영제부작용이 40분, 금식 등 전처치 미흡이 120분, 메트포민제제 당뇨약 복용이 30분, 기타 사유가 60분으로 나타났다. 2015년 1월~2 월 전처치 프로세스 시스템을 적용하여 전처치가 필요한 대상자 644명중 SMS 전송시행율은 515건(80%)으 로 나타났으며, SMS 전송내역을 분석한 결과 당일 검사가 283건(44%), 진료과 방문이 185건(29%), 전처치 불필요가 47건(7%), 외래과에서 전처치 프로세스 시스템 미확인으로 SMS 전송이 안 된 건수가 129(20%)건 으로 나타났다. CT 조영검사 예약시간 준수율은 전체 644건 중 560건(87%)이 예약시간 안에 검사를 시행 하였으며, 예약시간보다 지연된 세부적인 사례는 creatinine 미확인이 23건(28%), creatinine 1.3이상이 11건(1 3%), 과거조영제부작용이 7건(8%), 금식 등 전처치 미흡이 30건(36%), 메트포민제제 당뇨약 복용이 6건( 7%), 기타 이유가 7건(8%) 이었다. 예약시간보다 평균 지연된 시간은 creatinine 미확인이 90분, creatinine 1. 3이상이 20분, 과거조영제부작용이 30분, 금식 등 전처치 미흡이 120분, 메트포민제제 당뇨약 복용이 30분, 기타 사유가 60분으로 나타났다.
조영제 부작용의 효율적인 관리적 측면과 CT 조영검사 예약시간에 검사가 원활하게 진행될 수 있도록 전처치 프로세스 시스템을 적용해본 결과 적용 전에 비해 전처치 준비 시간이 줄어들고 CT실, 진료실, 채 혈실, 주사처치실 등의 방문횟수 및 동선이 줄어들어 CT실을 찾는 고객들의 검사만족도와 의료서비스 향 상에 기여가 될 것으로 사료된다.