This study investigates the risk reduction effect and identifies the optimal capacity of Multi-barrier Accident Coping Strategy (MACST) facilities for nuclear power plants (NPPs) under seismic hazard. The efficacy of MACST facilities in OPR1000 and APR1400 NPP systems is evaluated by utilizing the Improved Direct Quantification of Fault Tree with Monte Carlo Simulation (I-DQFM) method. The analysis encompasses a parametric study of the seismic capacity of two MACST facilities: the 1.0 MW large-capacity mobile generator and the mobile low-pressure pump. The results demonstrate that the optimal seismic capacity of MACST facilities for both NPP systems is 1.5g, which markedly reduces the probability of core damage. In particular, the core damage risk is reduced by approximately 23% for the OPR1000 system, with the core damage fragility reduced by approximately 72% at 1.0g seismic intensity. For the APR1400 system, the implementation of MACST is observed to reduce the core damage risk by approximately 17% and the core damage fragility by approximately 44% under the same conditions. These results emphasize the significance of integrating MACST facilities to enhance the resilience and safety of NPPs against seismic hazard scenarios, highlighting the necessity for continuous adaptation of safety strategies to address evolving natural threats.
최근 국내에서 연간 지진 발생 횟수가 꾸준히 증가함에 따라 공공시설물에 대한 내진 보강의 필요성이 더욱 대두되고 있다. 이 연구 에서는 사각 단면을 가진 철근콘크리트 기둥에서 강봉보강의 유무에 따른 내진 성능 개선 효과를 분석하기 위해 비선형 유한요소해 석을 수행하였으며, 검증을 위해 구조실험결과와 비교하였다. 분석 결과, 이 연구에서 수행한 유한요소해석이 실제 강봉보강공법을 적용한 철근콘크리트 기둥의 구조 거동을 합리적으로 잘 묘사하는 것으로 나타났다. 또한, 해석 및 실험 모두 강봉보강공법 적용으로 인해 파괴모드가 취성파괴에서 연성파괴로 전환되었으며, 강도와 연성도 모두 증가하는 것으로 나타났다. 따라서, 강봉보강공법 적 용을 통해 기존 철근콘크리트 기둥의 내진 성능을 효과적으로 증진시킬 수 있는 것으로 판단된다. 이 연구의 주요 결과는 향후 설계 방 안 마련 등 관련 연구에 유용할 것으로 기대된다.
In 2016, an earthquake occurred at Gyeongju, Korea. At the Wolsong site, the observed peak ground acceleration was lower than the operating basis earthquake (OBE) level of Wolsong nuclear power plant. However, the measured spectral acceleration value exceeded the spectral acceleration of the operating-basis earthquake (OBE) level in some sections of the response spectrum, resulting in a manual shutdown of the nuclear power plant. Analysis of the response spectra shape of the Gyeongju earthquake motion showed that the high-frequency components are stronger than the response spectra shape used in nuclear power plant design. Therefore, the seismic performance evaluation of structures and equipment of nuclear power plants should be made to reflect the characteristics of site-specific earthquakes. In general, the floor response spectrum shape at the installation site or the generalized response spectrum shape is used for the seismic performance evaluation of structures and equipment. In this study, a generalized response spectrum shape is proposed for seismic performance evaluation of structures and equipment for nuclear power plants. The proposed response spectrum shape reflects the characteristics of earthquake motion in Korea through earthquake hazard analysis, and it can be applied to structures and equipment at various locations.
To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.
국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으 로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위 관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.
In this study, seismic performance of bushings and their connection parts was analyzed by performing shaking table tests for various types of bushings widely used as auxiliary equipment of main transformers in domestic substations. As a result of the seismic tests of five types of 154 kV bushings according to the manufacturers, all the bushings secured the structural integrity even at the acceleration of 1.4 g and it was found that leakage of insulating oil didn't occur. Also, the average acceleration amplification rate at the upper part of the bushings was about 2.5 to 3.0 times higher than the lower one. On the other hand, when a representative 345 kV bushing was subjected to the seismic test, the structural integrity was secured even at 1.0 g acceleration similar to the design earthquake load level, but in this test, leakage of insulating oil occurred. However, when a stiffener restricting the connection of the bushing is installed in the same 345 kV bushing, the displacement of the bushing connection is controlled and the stiffener prevent the oil from leaking even at the acceleration of the designed seismic level.
본 연구에서는 역량스펙트럼법을 이용해 얻어진 구조물의 성능점을 확률적으로 평가하는 방법을 제시하였다. ATC-40에 따라 역량스펙트럼법을 이용하여 4층 1경간 철골구조물의 성능점을 산정하였다. 요구스펙트럼을 이용하여 구조물의 성능한계를 초과하는지 여부를 분석하기 위해 구조부재의 소성변형각으로부터 정의되는 구조물의 성능한계에 대해 한계변위를 도출하였다. 또한 설계응답스펙트럼과 유사한 응답스펙트럼을 가지는 인공지진파 30개를 선정하여 스펙트럼 가속도에 따른 각 성능한계의 초과여부를 통해 fragility curve를 도출하였다. 관측된 초과확률을 이용하여 fragility curve를 도출하기 위해 maximum likelihood method를 사용하였다. 각 성능한계점에 대응하는 설계응답스펙트럼의 응답가속도값에서 성능한계점을 초과할 확률은 존재하는 것으로 확인되었다. 본 방식은 구조물의 성능점에 대해 지진파의 불확실성을 고려한 확률적 평가가 가능하고, 시간증분해석이 필요하지 않아 해석시간을 상당부분 단축시킬 수 있다는 장점이 있다.
In this paper, some popular intensity measures of earthquakes including magnitude, MMI, and PGA as well as their empirical relationships are briefly reviewed since they have been widely used without prudence by mass media, the public, and even the government when asking or expressing the seismic capacity of buildings. The basic concept of current seismic design is also presented in order to facilitate relevant discussions. It is emphasized that expressing the building seismic capacity simplistically in terms of seismological quantities or terminologies like magnitude and MMI is inherently irrational, may be misleading the stakeholders, and should be avoided. Alternative expressions, more rational and consistent with current seismic design philosophy and practice, are recommended.
본 연구에서 피뢰기의 지진취약도 해석은 역량스펙트럼 방법을 이용하여 수행하였다. 많은 구조부재를 가진 구조물의 지진취약도 해석은 수십 혹은 수백 개의 지진하중에 대한 비탄성 지진응답을 계산하는 것이 요구되기 때문에 역량스펙트럼 방법과 같은 간단한 방법이 응답이력해석 보다 적합하다. 일반적으로 역량스펙트럼 방법에 의해 평가된 지진응답의 정확성은 응답이력해석에 의한 결과의 정확성 보다 떨어진다. 역량스펙트럼 방법의 정확성을 향상시키기 위하여 등가단자유도 방법과 성능점 계산기법이 적용되었다. 지진취약도에 대한 지진에 대한 지반효과를 평가하기 위하여 60개의 다른 지반종류의 지반운동을 입력지진으로 선정하여 사용하였다. 역량스펙트럼 방법과 응답이력해석에 의한 지진취약도 곡선의 비교로부터 역량스펙트럼 방법에 의한 지진취약도 곡선이 응답이력해석에 의한 지진취약도 곡선과 상당히 유사함을 알 수 있었다. 또한, 피뢰기의 주된 지진에 의한 파괴모드는 부싱의 파손임을 알 수 있었다.
This paper is the sequel of a companion paper (I. Performance Evaluation) evaluating the relation between the seismic performance of steel intermediate moment frames (IMFs) and the rotation capacity of connections. The evaluation revealed that the seismic performance of IMFs having the required minimum rotation capacity suggested in the current standards did not meet the seismic performance criteria presented in FEMA 695. Therefore, thepresent study evaluates the causes of the vulnerable seismic performance for steel IMFs and proposes alternatives to satisfy the seismic performance suggested in FEMA 695. To that goal, the results of nonlinear analysis, which are the pushover analysis and the incremental dynamic analysis, are examined and evaluated. As a result, high-rise IMF systems are seen to have the lower collapse margin ratio after connection fracture than row-rise IMF systems and, the actual response isfound to compared tothedesign drift ratio acting on design load design. Finally, the minimum design load values are proposed to meet the seismic performance suggested in FEMA 695 for IMF systems having vulnerable seismic performance.
The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.
This study proposed proposes a retrofitting method using an H‐beam frame to improve the seismic performance of non‐seismic designed reinforced concrete frames. To evaluate the seismic performance with the H‐beam frames, a cyclic lateral load test was performed and the experimental result was compared with the bared frame, and a masonry infilled RC frame. The results was were analyzed regarding aspects of the load‐displacement hysteresis behavior, effective stiffness, displacement ductility, and cumulative energy dissipation. AlsoIn addition, it was possible to prove both an increase of in the maximum load capacity, effective stiffness, and energy dissipation capacity using the H‐beam frame.
In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress(138 MPa) of the piping system even under the maximum excitation level of this test.
본 연구에서는 지진시 앵커기초의 파괴한계성능을 평가하기 위하여 진동대 실험을 수행하였다. 앵커기초에 발생 가능한 열화현상인 균열의 영향을 평가하기 위하여 균열이 없는 시편, 관통균열 시편 그리고 파괴예상면 내에 측면균열이 있는 시편을 제작하여 각각의 파괴한계성능을 평가하였다. 우선적으로 임팩트 해머에 의한 가진 실험을 통하여 동특성분석실험을 수행하여 실험모형의 동특성을 분석하였으며, 앵커기초의 파괴 시까지 진동대 실험을 수행하여 극한거동을 평가하였다. 최종적으로 앵커기초의 설계기준과 비교하여 거동특성을 분석하였다.
프리캐스트 콘크리트 골조에서 실물크기의 보-기둥 접합부 실험체 5개를 대상으로 반복가력 실험을 수행하였다. 지진하중을 받는 골조를 대상으로 1개의 일체식 실험체와 4개의 프리캐스트 실험체를 포함하여 5개의 1/2스케일의 내부 보-기둥 접합부를 대상으로 하였다.주요 변수는 보의 구조적 연속성을 확보하기 위한 접합부의 형태와 접합부의 특별한 보강형태(섬유콘크리트와 횡보강근)로 하였다. 실험체는 강기둥-약보 개념에 따라 설계하였다. 보 철근은 접합부에 큰 비탄성 전단력이 작용할 경우 보에 소성힌지가 발생하도록 계획하였다. 접합부의 성능평가는 접합부의 강도, 강성, 에너지 소산능력과 층간변위비로 평가하였다. 실험결과 실험체의 파괴는 보의 소성힌지부에서 파괴되었다. 보-기둥 접합부의 성능은 대체적으로 우수한 것으로 나타났다. 접합부의 강도는 일체식 RC 구조의 비해 1.15배 정도 향상되었다. 층간변위 3.5%때의 강도에서 실험체는 ECC의 인장변형능력과 철골연결재의 항복에 의해 연성거동 하였다.
지진피해를 입은 건물의 주된 관심사는 건물에 남아 있는 내진성능 및 여진에 대한 안전성을 판단하는데 있다. 따라서 지진피해를 입은 지역 사회의 조속한 복귀를 위해서는 건물의 잔존내진성능 평가방법을 확립해 두는 것이 필수적이다. 본 연구에서는 무보강 조적채움벽체를 갖는 RC 건물의 잔존내진성능 평가방법 개발을 주목적으로, 전형적인 학교건물을 대상으로 축력레벨을 변수로 한 실스케일, 단층 1스팬 실험체를 제작하여 정적 반복가력실험을 실시하였다. 실험 중 잔존내진성능을 판정하는데 유용한 정보 중 하나인 잔류균열폭을 상세히 측정하였다. 본 논문에서는 잔류균열폭과 잔존내진성능과의 관계에 대해서 실험적, 해석적으로 검토하고 잔존내 진성능 평가를 위한 각 손상도 레벨에 대응하는 내진성능 저감계수를 제안한다.
최근 들어 구조물의 내진성능평가법으로서 간편법인 역량스펙트럼법이 건축물을 비롯한 교량분야에도 활용되고 있다. 현재까지의 연구는 대부분 대칭성을 갖는 정형화된 형상의 교량을 대상으로 하는 연구가 진행되어 왔다. 이 논문에서는 역량스펙트럼법을 비정형 곡선교에 적용시켰을 때의 실용성을 검토하였다. 이를 위해 3경간 연속 곡선교의 비탄성 내진성능을 역량스펙트럼법과 시간이력해석법으로 평가하였다. 곡선교의 응답은 단순 3경간 대칭형 직선교의 응답과 비교하고, 곡선교의 원호각의 정도에 따른 비탄성변위응답의 변화를 분석하였다. 역량스펙트럼법에 의한 평가결과는 비선형 시간이력해석법에 의한 결과와 비교하였다. 입력운동으로 사용한 지반 운동은 실제 기록 지진 중에서 선별된 El Centro지진과 Kobe지진이다. 해석결과, 역량스펙트럼법이 시간이력해석방법에 비하여 대체적으로 변위응답을 크게 산출하고 있는 것으로 확인되었다. 역량스펙트럼법에 의한 해석결과로 얻어진 직선교에 대한 변위 응답 값은 시간이력해석결과와 대체적으로 일치하고 있다. 하지만 곡선교의 원호각이 커질수록 교각의 비탄성 변위는 직선교의 비탄성 변위와 비교하였을 때 그 차이가 증가되는 것으로 확인되었다.
본 연구에서는 전력설비 중 그 중요도가 가장 큰 변압기를 대상으로, 지진 발생 시 변압기의 파손을 방지하기 위하여 마찰진자 면진장치를 개발하고, 진동대시험을 통하여 그에 대한 내진성능을 입증하였다. 본 연구에서 개발한 마찰진자 면진장치에 대해 압축재하시험 및 마찰시험을 수행한 결과, 변압기의 면진장치로서 적용 가능한 것으로 나타났으며, 특히 변압기 축소모형을 대상으로 진동시험대에 의한 내진성능시험을 수행한 결과, 기존의 일반 고정기초형식보다 변압기 기초부의 최대 응답가속도는 약30%, 부싱 상단의 최대 응답가속도는 약 59% 감소하였다. 또한, 마찰진자 면진장치 설치 후, 변압기의 고유진동수가 약 82% 감소하며 장주기로 이동함을 확인할 수 있었다. 이와 같이 변압기에 마찰진자 면진장치를 적용하는 경우, 지진으로 인한 변압기의 파손을 효과적으로 방지할 수 있을 것으로 판단된다.
현행 내진설계에서 반응수정계수는 탄성 밑면전단력을 저감하여 설계하중 수준을 정의하기 위한 주요 계수로 사용되고 있다. 이제까지 반응수정계수는 공학자들의 경험적인 합의에 의하여 정성적으로 설계기준에 반영하고 있다. 구조시스템에서 반응수정계수와 접합부의 가용 회전능력은 매우 밀접한 관계가 있으며, 본 논문에서는 이러한 접합부의 회전능력과 비선형 푸쉬오버 해석에 기초하여 반응수정계수를 평가하는 방법을 제시하였다. 이를 검증하기 위하여 IBC 2000에 따라 설계된 R3S 골조를 대상으로 제안 방법을 적용하였다. 또한, 다양한 지진파에 대한 비선형 시간이력 해석을 병행하여 가용 회전능력에 의거하여 산정된 반응수정계수의 타당성을 평가한 결과, 본 제안방법에 따라 정의된 반응수정계수가 충분히 보수적임을 확인하였다.