검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 37

        21.
        2005.08 구독 인증기관 무료, 개인회원 유료
        This paper proposes substructuring method using experimental model of only upper MDOF structure and verifies its applicability to shaking table test. The structure considered in the test is a five-stoty shear type building model which is divided into two parts, of which one is lower three floors for a numerical substructure and the other is upper two floors for a experinlental substructure. The experimental substructure is excited by the shaking table and the acceleration data for the input of shaking table is obtained numerically from lower numerical part. For implementation of the proposed substructuring method, a controller of the shaking table is designed reflecting experimental model. In comparison with acceleration responses, which are measured from experinlental part of 3rd, 4th, and 5th floor and are numerically calculated from the original five-stoty structure, it is observed that the experimental results match well with the numerical results in both time and frequency domain.
        4,000원
        22.
        2004.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 원전기기의 내진안전성을 증가시키기 위해 면진장치를 적용한 기기의 진동대 실험을 수행하였다. 원전구조물과 유사한 진동수 특성을 가지는 실험모형을 제작하여 실험에 사용하였으며 구조물 내부의 기기를 모형화 하기 위하여 400kg의 강체를 사용하였다. 탁월주파수 특성이 상이한 3종류 지진파를 이용하여 진동대 실험을 수행하였다. 면진장치로는 마찰진자형 베어링(FPS)을 사용하였다. 입력지진의 최대가속도를 0.1g, 0.2g, 0.25g의 3단계로 변화시키면서 실험을 수행하였고 또한 1방향, 2방향 및 3방향 가진에 의한 거동을 분석하였다. 실험결과 지진파의 연직성분이 FPS의 면진성능에 영향을 미치는 것을 알 수 있었으며 펄스타입의 속도성분이 큰 근거리 지진인 경우 면진효과가 감소하는 것을 알 수 있었다.
        4,200원
        23.
        2004.08 구독 인증기관 무료, 개인회원 유료
        In this paper, the stiffness and damping matrices are experimentally constructed using the structural modal information on frequencies, damping ratio and modal vectors, which are obtained by shaking table tests. Free vibration, harmonic and white noise vibration tests are performed. The acceleration of the shaking table was used as the input signal, and the resulting accelerations of each floor were measured as output signals. The characteristics and limitations of modal information from the each test are compared. The results of this study would be a basic resource of the analytical and experimental studies on the system identification of structures
        4,000원
        24.
        1998.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 능동질량 장치를 이용하여 지진하중을 받는 건물모델의 응답을 제어하는 것으로서 실험에 사용된 능동질량 장치는 교류형 서보 모터에 의해 관성력이 건물모델의 응답에 반작용하여 제어를 하게 되는 원리를 이용한 것이다 소형 진동대에 의한 외부하중 묘사 신호처리와 제어력 발생을 위한 장비들이 구축된 실험 모델로써 능동 질량 추진기가 1층 전단형 건물모델 상부에 설치된 해석 모델을 실현하였으며 제어력 산정을 위한 선형 2차 제어 알고리듬은 LabVIEW 프로그램을 사용해서 구현하였다. 건물의 응답과 제어력을 고려해서 제어성능을 검증하였으며 능동 질량 장치를 설치함으러써 공진하중과 지진하중에 대한 건물의 응답이 감소하고 또한 속도피드백 알고리듬이 그 외의 피드백 알고리듬 보다 제어력이 가장 적게 소용되면서 건물의 응답을 감소시키는 것을 실험적으로 파악하였다.
        4,000원
        25.
        1997.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구의 목적은 진동대를 사용한 지진모의 기술의 현상황을 살펴보고 그의 신뢰성을 검토하는 것이다. 1자유도 및 3자유도 알루미늄 전단구조 모델이 사용되었으며, 4m{\times}4m 6자유도 진동대가 1940 El centro 지진 가속도 기록(NS요소)를 재현하기 위해 수평 1방향으로 흔들어졌다. 진동대의 실제 가속도 이력과 목표 가속도 이력을 비교할 때, 전반적인 이력은 매우 흡사했으나 실제 진동의 저 주파수 영역은 목표치보다 후리에 변환 강도에서 낮은 값을 대체로 나타내고 있었다. 자유진동 및 백색파 실험은 고유주파수에 대해서는 거의 일치하는 값을 나타내고 있으나 감쇠계수에 대해서는 자유진동실험의 경우 1.4%, 백색파실험의 경우 14.8%를 나타내어 큰 차이를 보여주고 있다. 층 전단력 대 층간변위의 이력곡선으로부터 전제적으로 선형탄성거동을 나타내고 있으나 이 이력곡선의 모습이 층 강성을 한축으로 하는 타원형을 나타내어 점성감쇠의 영향을 암시하고 있다.
        4,000원
        26.
        2019.10 서비스 종료(열람 제한)
        2009년 개소한 부산대학교 지진방재연구센터는 국내 최대 규모의 진동대 연구장비 보유기관으로 지진방재분야의 다양한 실험연구, 내진기술과 제품에 대한 공인시험 및 검증평가를 지원하고 있으며, 내진시험 방법의 표준화 연구 등 국가연구개발 과제의 수행, 민간기업 연구개발 지원과 컨설팅, 교육사업 등을 수행하고 있다. 연구역량 강화를 위해 국내 내진연구 분야 기관 및 전문가그룹과 협력체계를 구축하고 있으며, 일본의 E-Defense(NIED), 대만의 NCREE, 유럽의 JRC, 미국의 EERC 등 국외 연구기관과도 국제공동연구 네트워크를 구축하고 있다.
        27.
        2019.04 서비스 종료(열람 제한)
        The contact displacement sensors that are currently becoming popular in the shaking table tests are limited depending on their use environments; thus, the reality is that each equipment appears impractical considering its effectiveness and applicability. Therefore, in this study, to verify an algorithm for measuring the displacement responses of a structure using the line detection in the shaking table test, the test was conducted on a reinforced concrete frame.
        28.
        2018.10 서비스 종료(열람 제한)
        An advanced lumped-mass stick (LMS) model is developed to improve the dynamic response accuracy of the conventional LMS model. In order to display the performance of the advanced LMS model, a four-story frame structure is prepared and performed a shaking table test using several earthquake ground motions. The frame structure consists of stainless steel and mass plates. The horizontal natural frequencies of first to fourth mode are 1.86Hz to 48.83Hz. In this paper, the seismic responses resulted from the advanced LMS model of the structure are compared with the results of the shaking table test.
        29.
        2018.10 서비스 종료(열람 제한)
        The seismic performance evaluation for the electrical cabinets is conducted by the shaking table test or numerical analysis. When performing the seismic evaluation by the numerical analysis, it usually assumes that the electrical cabinets are rigidly anchored to the floor. This assumption may not be valid depending on how the cabinets are anchored. In particular, if a cabinet is anchored with bolts, a local plastic deformation of the base plate of the cabinet may cause rocking. Therefore, in this study, the shaking table test was performed to analyze the rocking effect of the electrical cabinet in an experimental method.
        30.
        2018.10 서비스 종료(열람 제한)
        Piloti structure is a building designed to open the ground floor as a basic principle of modern architecture. However, it is considered urgent to prepare seismic retrofit plans for the irregular torsion problem of the Piloti building through the recent Pohang earthquake. Therefore, this study aims to provide the basic data for the selection of the Piloti building seismic retrofitting method by comparing the dynamic characteristics of each method through the small shaking table experiment using the seismic retrofitting method of the pilotty building.
        31.
        2018.04 서비스 종료(열람 제한)
        An advanced lumped-mass stick (LMS) model introduced in this paper is to overcome the disadvantages of the conventional lumped mass stick model, such as frequency error and low accuracy of dynamic responses. In order to show the performance of the advanced lumped-mass stick model, the experimental test using shaking table is conducted, considering a scaled four-story frame structure. The material of the frame model is stainless and the total mass of the model is about 39kg. The displacement and acceleration responses resulted from the advanced LMS model are compared with those of experimental results, including the response results of the conventional LMS model of the frame model.
        32.
        2018.04 서비스 종료(열람 제한)
        In the shaking table test, contact displacement sensors are widely being applied to a structure for measuring the displacement responses, but difficulties may arise depending on the condition of the structure. Moreover, the test uneconomically needs temporary facilities for installing sensors and supplementary equipment for saving the displacement responses of a structure. The contact displacement sensors that are currently becoming popular in the shaking table tests are limited depending on their use environments; thus, the reality is that each equipment appears impractical considering its effectiveness and applicability. Therefore, in this study, to verify an algorithm for measuring the displacement responses of a structure using the vision-based system in the shaking table test, the various tests were conducted.
        33.
        2015.10 서비스 종료(열람 제한)
        the primary objective of this research is to reduce the damage of critical frame structures such as hospitals and schools during and after an earthquake. this study develop the infill panel to allow smaller shear deformation with sliding of the specific element in the panel. As a result, the side sway was significantly reduced in the structure with infill panel, in comparison to the steel frame structure without infill panel during the experimental test
        34.
        2012.11 서비스 종료(열람 제한)
        This study conducted seismic performance evaluation of externally reinforced water tank using shaking table test. From the shaking table test result, externally reinforced system shows sufficient stiffness for water tanks and high natural frequency over 8Hz. The test result also showed safety result of induced maximum stress of water tank shown in the allowable stress.
        35.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        지하역사의 대부분은 지진에 대비한 내진설계가 거의 수행되지 않음으로 인하여 일정규모 이상의 지진이 발생할 경우 대규모 인명 및 재산피해가 우려된다. 지중구조물인 지하역사의 신뢰도 높은 내진성능 평가를 위하여 지진하중 재하 시 지반과 구조물의 상호작용이 고려된 거동의 고찰과 검증이 요구된다. 이에 본 연구에서는 수도권 소재의 실제 지하역사에 대하여, 상사비 1/60 스케일의 축소모형 지하역사 구조물 시험체에 장주기인 Kobe지진파와 단주기인 Northridge지진파를 적용한 원심모형 진동대 시험을 수행하였다, 원심모형시험결과와 응답변위법, 동일단면에 대해 SHAKE91에 의한 지반 및 구조물의 상대변위, 구조물의 모멘트에 대하여 비교․분석함으로써 지하역사의 내진성능을 평가하고자 하였다.
        36.
        2011.02 서비스 종료(열람 제한)
        최근 전 세계적으로 지진의 발생 횟수가 증가하고 그 규모도 대형화 되면서 우리나라에서도 대형지진발생 가능성이 제기되고 있다. 우리나라 저층 구조물의 50% 이상을 차지하는 비보강 조적조 건축물은 노후화되었고 내진설계가 적용되지 않았을 뿐만 아니라 구조형식 자체가 중력저항형식으로 지진하중에 매우 취약한 구조이기 때문이다. 지진이 발생할 경우, 조적조 건축물의 붕괴로 인하여 막대한 인명피해 및 재산피해가 발생할 것으로 예상된다. 따라서, 본 연구에서는 실물크기의 2층 조적조 건물을 대상으로 선행연구1)에서 제안된 내진보강공법의 적용유무에 따른 진동대 실험을 수행하여 비보강 및 내진보강 조적조 건물의 거동 및 파괴형상과 제안된 내진보강방법의 내진성능을 평가하는 것을 본 연구의 주된 목적으로 한다. 실험체는 실대형 조적조 건물을 진동대의 크기 및 용량을 고려하여 2층으로 계획하였고, 4면의 벽체에 대하여 벽체의 크기, 개구부의 유무, 개구부의 크기 및 위치를 변수로 하여 제작하였다. 내진보강 실험체는 선행연구1)에서 제안된 바와 같이 지진 취약부 및 면외방향으로 메탈라스 및 강판 띠를 설치하여 내진보강 하여 제작하였다. 지진파는 El-Centro NS파(1940년, PGA=350gal)로 최대가속도를 기준으로 실험체의 파괴모드를 고려하여 스케일을 증가시키면서 가진하였다. 비내진보강 실험체는 개구부 전단균열, 바닥슬래브-벽체 접합부파괴가 주된 파괴형태로 나타났으며, 가진스케일 증가에 따라 균열이 확장되며 최종파괴에 이르렀다. 내진보강 실험체는 지진취약부 집중보강으로 인해 개구부 전단균열은 미미하였고, 가진스케일의 증가에 따라 실험체 전체의 강체거동에 의해 바닥슬래브-벽체의 파괴에 의해 실험이 종료되었다. 내진보강 실험체는 비내진 실험체에 비해서 변위응답이 2배이상 증가하여 연성능력이 향상되었고, 가속도 응답도 약 20%이상의 응답 저감효과를 보였다. 입력에너지 또한 비보강 실험체에 비해 4배 이상의 에너지 흡수능력을 보여 우수한 내진보강효과가 발휘된 것으로 나타났다.
        1 2