In the development of eco-friendly vehicles such as electric vehicles, weight reduction has become a very important design target. Seat weight reduction is very important in vehicle weight reduction. In this study, the energy absorption characteristics of Almag material, an alloy of aluminum and magnesium, and mild steel SAFH440, SAFH590, SAFC780, and SAFH980 were analyzed to obtain a true stress versus true strain curve that was correlated with the test. By performing the seat frame structure analysis using the obtained analysis material property, it was possible to compare the deformation between lightweight material, Almag and mild steel materials. In addition, it was confirmed that the weight reduction effect was 25.8% when applying Almag, an equivalent lightweight material that gives the same maximum deformation as SAFH980, a high-strength mild steel.
OWEC(Overtopping Wave Energy Converter)는 월파된 파도를 이용한 파력발전시스템이라한다. OWEC의 성능 및 안전성은 파고, 주기 등 파도의 특성에 의해 영향을 받는다. 따라서 해역 특성에 따른 OWEC의 최적 형상과 구조안전성에 관한 연구가 필요하다. 본 연구 에서는 울릉읍 연안 해양 환경 데이터를 이용하였으며, SPH(Smoothed Particle Hydrodynamics) 입자법 해석을 통해 기존 케이슨 하부 구조에 변화를 준 모델 4개를 비교하여 월파 효율을 분석하였다. 그 결과, 하부 구조의 변경 및 경량화가 가능함을 확인하였다. 최적화 해석을 통 해 설계 하중에 내하력을 가지는 하부 구조인 새로운 트러스형 구조를 제안하였다. 이후 부재 직경 및 두께를 설계변수로 하는 사례 연구 를 통해 허용응력조건 하에서 구조 안전성의 확보를 확인하였다. 주기적인 파랑 하중을 받기 때문에 제안하는 구조의 고유 진동수와 해 당 해역의 파주기를 비교하였으며, 1년 재현 주기의 파랑을 하중으로 한 조화응답해석을 수행하였다. 제안하는 하부 구조는 동일 가진력 에서 기존 설계 대비 응답의 크기가 감소하였으며, 기존 대비 32% 이상의 중량 절감을 수행하였다.
The work presented in this report was a detailed comparative study of the electrochemical response exhibited by graphite anodes in Li-ion batteries having different physical features. A comprehensive morphological and physical characterization was carried out for these graphite samples via X-ray diffraction and scanning electron microscopy. Later, the electrochemical performance was analyzed using galvanostatic charge/discharge testing and the galvanostatic intermittent titration technique for these graphite samples as negative electrode materials in battery operation. The results demonstrated that a material having a higher crystalline order exhibits enhanced electrochemical properties when evaluated in terms of rate-capability performance. All these materials were investigated at high C-rates ranging from 0.1C up to 10C. Such improved response was attributed to the crystalline morphology providing short layers, which facilitate rapid Li+ ions diffusivity and electron transport during the course of battery operation. The values obtained for the electrical conductivity of these graphite anodes support this possible explanation.
This project is mainly related to evaluation of total energy consumption of low energy house, the exterior envelope of which was wholly composed of structural insulated panels(SIP). The U-value of applied SIP was in the range of 0.189 to 0.269W/㎡․K and the U-value of pair glass from 0.78 to 1.298W/㎡․K was applied for window dependent to its function respectively. For comparison of total energy performance, the energy simulation for pilot house was performed to compare with the control house having insulation criteria of Korean building regulation in 2009. Based on simulation of dynamic energy performance, the pilot house saved 48.3% of annual energy consumption while the control house in 2009 consumed as 85.7GJ/y. In case of heating, the result showed that the energy saving ratio amounted to 76.7%. For CO₂ emission, the pilot house diminished approximately 35.4% from 6,208.4kgCO₂ to 4,009.2kgCO₂. In payback period to early investment, it was analyzed the pilot house took 7.8 years, when the low energy house built by other insulation method with same thermal perfusion took 11.5 years. From this result, it is considered that the SIP is more effective, economic to Green Home application.
Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard (0.225W/㎡·K). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.
에너지 설계법은 지진에 의해 누적된 손상과 구조물의 이력거동에 의한 영향을 직접적으로 고려할 수 있기 때문에 현행 내진설계 기준보다 더 합리적이다. 그러나 지반운동과 구조물 특성에 따른 에너지 응답에 대한 관련 연구자들의 합의가 아직 도출되지 않고 있다. 따라서 본 연구에서는 에너지 요구에 대한 지진하중과 구조물 특성의 영향을 다른 지반조건에서 계측된 100개의 지진기록을 이용하여 평가하고 기존 연구결과와 비교하였다. 해석 결과에 따르면 연성비와 지반조건은 입력에너지에 상당한 영향을 주는 것으로 나타났다. 입력에너지에 대한 이력에너지비는 연성비, 감쇠비와 강한 지진파의 지속시간에 많은 영향을 받았지만 지반조건에 따른 변화는 작았다.
최근 능력스펙트럼법, 직접변위기초설계법 등과 같은 성능에 기초한 내진 평가/설계법이 개발되어 사용되고 있다. 이들 방법은 구조물의 비선형 주기거동에 의한 에너지 소산능력을 고려함에 있어 부정확한 경험식에 의존하는 한계를 보이고 있다. 한편, 최근 연구에서 휨지배 철근콘크리트 부재에 대하여 여러 설계변수의 영향을 고려하여 주기거동에 의한 에너지 소산능력을 정확히 평가할 수 있는 방법이 개발되었다. 본 연구에서는 에너지 소산능력을 고려한 내진설계법에 대한 기초적인 연구로서, 최근 연구에서 개발된 에너지 소산능력 산정법을 이용한 철근콘크리트 전단벽 구조의 내진설계법을 개발하여, 기존의 내진설계법과 비교하였다. 제안된 설계법에서는 단면의 크기 및 형상, 축력, 철근비, 배근형태, 연성도 등과 같은 다양한 설계변수에 따른 에너지 소산능력의 변화를 정확히 고려하여 설계할 수 있다.
가중행렬은 일반적인 최적 제어 설계에서 우선적으로 필요하지만 일반적으로 제어 설계자들 이 경험적 지식에 의존하고 있다. 이 논문은 구조물의 에너지를 고려한 최적제어기의 가중행렬을 결정하는 체계적인 절차를 제시하였다. 최적제어기는 LQR과 ILQR로 구분될 수 있다. 구조물의 총에너지를 고려한 Lyapunov 함수를 적용하고, 이로부터 유도된 식이 음수라는 상태를 이용하면 가중행렬을 어렵지 않게 구할 수 있다. 이러한 방법으로 산정된 가중행렬을 이용하여 LQR과 ILQR제어기를 설계하고 제어효율을 입증하였다.
Energy and energy consumption play an important role in strategies for socio-economic development of the country. In 1995, Vietnam officially entered the 500 kV North-South transmission power line exploits, with a full length of 1,487 km. The purpose of this study is to investigate the breakpoint and the transition effect of energy consumption to economic growth in Vietnam during the period of 1980-1994, and 1995-2016. The Autoregressive Distributed Lag (ARDL) approach and the Bounds test are used to test for the presence of cointegration, whereas the Toda and Yamamoto procedure Granger causality test is used for the direction of causality. The result of the Bounds test validates the existence of cointegration among the included variables. The empirical results provide evidence that energy consumption has a positive impact on the economic growth of Vietnam in the long run. The causality test shows that there is bi-directional causality between energy consumption and economic growth, supported feedback hypothesis. There is a breakpoint in 1995 and the contribution of energy consumption in economic growth in the period of 1995-2016 is lower than the stage 1980-1994. This study suggests Government authorities explore new sources of energy to achieve sustainable economic development in the long run.
In this paper, we suggest the new floating type photovoltaic energy generation system, which is improved the structural and economical efficiency, compared with the system developed in the previous research. The structural system in new floating type photovoltaic energy generation system reveals better in structural performance.