        검색결과 49

        21.
        2018.04 서비스 종료(열람 제한)
        In this research, new structural design and manufacturing method of atypical irregular UHPC structural members were newly introduced. The atypical irregular UHPC member was optimized to design from the conventional rectangular section and a method of nonuniform formwork system was newly created to manufacture the irregular member. The specimens were evaluated by analysis and the newly designed member was improved in bending performance by 2.6 times compared to conventional rectangular concrete beams.
        22.
        2017.09 서비스 종료(열람 제한)
        This study investigated the tensile properties of UHPC using by PE fiber. Test results showed that the UHPC with PE fiber has high tensile strain capacity compared with UHPC with steel fiber. PE Fiber content was not effective of the strength. But increase the PE fiber content was improved of tensile strain capacity.
        23.
        2017.09 서비스 종료(열람 제한)
        In the study, direct tensile test was conducted to perform statistical approaches to the maximum tensile strength of design strengths (120, 150 and 180 MPa), and then the direct tensile database construction was made to examine the reliability of the direct tensile test.
        24.
        2017.09 서비스 종료(열람 제한)
        In this study, flexural and tensile properties of pre-cast UHPC deck joints with surface treatment applied to fields were evaluated. It showed that all specimen set experimental variables satisfied sufficient resisting load efficiency and crack standard.
        25.
        2017.09 서비스 종료(열람 제한)
        It was studied structural design of nonuniform UHPC concrete structural members. UHPC concrete has the compressive strength of 120-200MPa, the tensile strength of 8-20MPa, and the tensile strain of 1.0-5.0%. There are two types of specimens of nonuniform members improved in bending and shear performances. The specimens were evaluated by beam load test induced by bending and shear failures.
        26.
        2017.04 서비스 종료(열람 제한)
        This research developed eco-friendly UHPC using industrial by-products (Ground Granulated Blast Furnace Slag, Bottom Ash) by replacing cement and silica powder. The Chloride Penetration Resistances of the developed eco-friendly UHPC were evaluated. It is found that the developed eco-friendly UHPC shows adequate compressive strength and enhanced chloride durability.
        27.
        2017.04 서비스 종료(열람 제한)
        This research was introduced new structural design of atypical irregular beams by applying UHPC which has the compressive strength of 80-200MPa, the tensile strength of 10-20MPa, and strain of 1.0-5.0%. There beam specimen were smaller than actual member in building and new forms created to construction the specimens. The specimens evaluated and the newly irregular beams could improve bending performance by 2.56 times compared to the conventional RC beams.
        28.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This research developed eco-friendly UHPC using industrial by-products (Ground Granulated Blast Furnace Slag, Bottom Ash) by replacing cement and silica powder. The Chloride Penetration Resistances of the developed eco-friendly UHPC were evaluated. It is found that the developed eco-friendly UHPC shows adequate compressive strength and enhanced chloride durability.
        29.
        2015.10 서비스 종료(열람 제한)
        This study investigated the compressive strength of UHPC according to fiber combination. Test results showed that the PE, PVA and basalt fiber mixtures have lower compressive strength than steel fiber mixture. Compressive strength reduction ratio of PE, PVA and basalt fiber mixtures were 0.95, 0.96 and 0.86, respectively.
        30.
        2015.10 서비스 종료(열람 제한)
        This study was intended to investigate the effect of sand particle size on the flowability and strength of UHPC. The experimental results indicated that the sand with the particle size of 0.45~0.89 mm led to the best performance in those properties of UHPC.
        31.
        2015.10 서비스 종료(열람 제한)
        This study is, when we pour the concrete, doing bonding shear performance evaluation to search the influence about an adhesive interface by a generated cold joint with a retardation time. In conclusion, this experiment shows that the higher a compressive strength of the concrete is, the higher a reduction ratio of the bonding shear strength is, and the instance of a none agitation and a compaction with 15 minutes of a retardation time are the lowest influence in a whole of the results; each of the reduction ratio of the bonding shear strength is approximately 4.5%.
        32.
        2015.04 서비스 종료(열람 제한)
        In this study, long term monitoring of tensile force of pre-tensioned prestressing strand embedded in UHPC ribbed deck by means of FBG sensor encapsulated into 7-wire prestressing strand. Based on the monitoring result for two years, it was confirmed that the technique proposed in this study offers efficient and robust way of monitoring the internal prestress of pre-tensioned PSC structures.
        33.
        2014.10 서비스 종료(열람 제한)
        In recent, high performance concrete structures can be developed using Ultra-High Performance Concrete (UHPC) which has mainly high compressive and tensile strength. Therefore, in reinforced concrete (RC) structures, it is possible to reduce structural elements and the cost of construction by reducing the amount of concrete and steel bars. This study compared and evaluated bending performances of RC and UHPC beams respectively and examined the design suitability of UHPC flexural members.
        34.
        2014.10 서비스 종료(열람 제한)
        Rolling fatigue test was performed to study the behavioral characteristics of prestressed rib-type UHPC deck built-in optical sensors for cable-stayed bridges. As the result, it was verified that this deck has sufficient structural fatigue performance and serviceability as a bridge deck.
        35.
        2014.10 서비스 종료(열람 제한)
        Rolling fatigue test was performed to study the behavioral characteristics of prestressed rib-type UHPC deck built-in optical fiber sensors for cable-stayed bridges. As the result, it was verified that this deck has sufficient structural integrity using optical fiber sensors
        36.
        2014.10 서비스 종료(열람 제한)
        A rolling fatigue test was carried out to evaluate the fatigue performance of the Ultra-High Performance Concrete(UHPC) ribbed deck for cable-stayed bridge. As a result, it was verified that this developed deck system has sufficient fatigue performance and serviceability as a bridge deck.
        37.
        2014.10 서비스 종료(열람 제한)
        In this paper, investigate the effect of the quality of fresh UHPC on the mixer type, it was found that the use of twin shaft mixer was fine. On the other hand, pan type mixer is required for adjustment mix proportion.
        38.
        2014.10 서비스 종료(열람 제한)
        This study was conducted for investigating effect of retardation time of secondary placement on shear bonding strength. Evaluation experiment on the shear bonding performance of UHPC(180MPa level concrete) was conducted according to retardation time and size of specimen. As a result, the smaller the size of specimen, the weaker the measured bonding performance of specimen. Also, comparing specimen which is o minute occurrence time of cold joint with specimen which is after 15 minutes, it showd 70% lesser shear bonding strength.
        39.
        2014.04 서비스 종료(열람 제한)
        The first ultra-high performance concrete (UHPC) bridge Deck in Korea was constructed by KICT. Thrice field tests were performed to estimate the structural performance of this bridge. As a result, this bridge has sufficient safety and serviceability as a highway bridge.
        40.
        2014.04 서비스 종료(열람 제한)
        The FBG sensor responses simultaneously to changes in thermal strain as well as elastic strain. Thus the total strain measured from a single FBG sensor shall be corrected to obtain the elastic strain by removing the temperature effect. This paper addresses how the temperature effect can be removed when the FBG sensor is encapsulated in a 7-wire steel strand. For this purpose, fundamental properties of the FBG sensor are identified through tests using a controlled temperature chamber. Then field measurements on a UHPC pi girder with the size of 11.0 m long, 5.0 m wide, and 0.6 m high have been conducted for about one year, and the prestressing force is estimated using the raw data from the FBG sensor and by applying temperature correction technique proposed in this study. Estimated results indicate that the proposed correction technique is executable for extracting the elastic strain from monitoring data using the FBG sensor in civil infrastructures.