        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
        4,000원
        3.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 범용유한요소해석 프로그램인 ABAQUS를 사용하여 국내에서 사용되는 콘크리트벽돌을 조적채움벽으로 가진 철근콘크리트 골조를 대상으로 유한요소해석을 실시하였다. 해석대상은 순수골조, 채움벽의 두께가 0.5B인 골조, 두께가 1.0B인 골조의 3종류이다. 철근콘크리트 골조 및 채움벽의 재료특성은 재료시험 결과로부터 구하였으나 두께가 1.0B인 채움벽의 경우 벽돌의 쌓기방법의 차이에 의해 0.5B 두께의 실험체보다 4배 정도 증가된 인장강도를 사용하였다. 유한요소해석결과는 실험을 통해 구한 하중-변위관계 및 변위각에 따른 균열양상을 상당히 정확하게 예측하였다. 유한요소해석 결과의 분석을 통해 조적채움벽과 골조사이의 접촉응력 및 골조의 전단력과 휨모멘트를 산정하였다.
        4,000원
        4.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The side wall thickness variation of the product to the process of ironing and the die pad was studied using a progressive die of the multi-stage drawing product in the process of ironing and the die pad. Experimental results because ironing is possible to increase the side wall thickness of the product is applied to the intermediate drawing process rather than applied in the initial process. The roundness and concentricity were easy control. A die pad is applied to a stand pad to the sixth step from the first step. The seventh step and the eighth step are applied integrated pad. The integrated pad of the seventh step and the eighth step appeared to be advantageous to control the roundness and concentricity.
        4,000원
        5.
        2008.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 초고층건물의 콘크리트 전단벽 아웃리거 두께를 산정하는 방법을 찾는 것이다. 이를 위해서 먼저 60층 규모의 초고층건물 해석모델을 생성하고 구조해석을 수행하였다. 다음에는 해석결과를 이용하여 아웃리거로 인한 하중 전달방식과 변형 양상의 변화를 고찰하고 이를 바탕으로 아웃리거 두께 산정식을 제안하였다. 마지막으로 해석모델을 다양하게 변화시켜 제안식의 타당성을 검토하였다.
        4,000원
        6.
        2017.09 서비스 종료(열람 제한)
        The purpose of this research is to develop a joint system for two concrete pipes with reduced wall thickness by a carbon fiber reinforced polymer (CFRP) fabric. As compared to conventional concrete pipe, the concrete pipe with the reduced wall thickness has more flexibility. However, the reduced wall thickness makes the conventional joint system not feasible. As an alternative joint, externally wrapping system with the CFRP fabric was proposed. The two CFRP widths (75mm and 150mm) were accounted for as a variable under joint shear test from ASTM C497M specification. The externally wrapping system showed 81.07% higher shear strength, as compared to the required shear strength by ASTM C497M.
        7.
        2015.02 서비스 종료(열람 제한)
        Sewage Pipe Renewal (SPR) method rehabilitate pipeline by forming a PVC profile inside the pipe by using a winding machine without excavating the soil above the pipe which lowers the cost of the rehabilitation. This study will investigate the effects of varying the pipe’s diameter to its wall thickness ratio. The dimensions for the diameter and minimum wall thickness of the non-reinforced concrete pipe will be based from ASTM C14. The finite element analysis software, ABAQUS, will be used to model and perform the analysis for the composite pipes. To account for the soil-pipe interaction, soil springs will be used as the bedding support to hold the pipe in place. Additionally, three soil types will be used to compare the behavior of the pipe with different diameter to thickness ratios. The results from the finite element analysis will be shown in tables and plotted into graphs and a concluding remarks will be provided.
        8.
        2014.04 서비스 종료(열람 제한)
        This paper indicates seismic performance of wing walls using Engineered Cement Composite(ECC) for retrofit of non-ductile existing building. The specimens consist wing walls of different thickness. The specimens is tested cyclic lateral loads. The test results indicated that wing walls seismic performance of 100 mm thickness improved than 70 mm wing walls.
        9.
        2010.01 KCI 등재 서비스 종료(열람 제한)
        도심지의 제한된 공간에서 대형 건축 지하구조물을 축조하기 위한 지하 굴토공사는 주변지반의 안정이 최우선 되어야 하며, 이를 위해서 흙막이 공사가 필수적으로 검토되어야 한다. 가설 흙막이 구조에서 응력부담재로 주로 사용되고 있는 H-Pile은 주열식 흙막이 벽체에서 지하외벽의 시공 이후에는 방치되므로 재료의 낭비를 초래하게 된다. 이를 개선하기 위하여 가설재인 H-Pile과 지하벽을 합성한 합성지하벽 공법이 개발되어 현재 많은 국내의 현장에 활용되고 있다. 본 연구에서는 지하합성벽의 전단내력을 평가하기 위하여 총 5개의 실험체를 제작하였다. 실험변수로는 전단연결재에 따른 합성율과 벽체 두께를 변수로 하여 실험을 실시하였으며, 기준식에서 제시하는 콘크리트 전단강도와 H-Pile의 전단강도를 실험값과 비교 분석하였다. 실험결과 합성율이 증가함에 따라 전단강도는 상승하지만 그 차이는 크지 않은 것으로 나타났다. 합성지하벽의 전단강도 산정시, 콘크리트 강재의 웨브 뿐만아니라, 강재플랜지의 기여도를 고려한 새로운 식을 제시하고 이를 이용한 계산결과와 실험결과를 비교한 결과 좋은 대응을 보이는 것으로 나타났다.