        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an accelerated weathering test was performed to examine the variation of thermal insulation performance according to the service life. A widely used class 1 thermal screen (matt georgette + polyethylene (PE) foam + chemical cotton + felt + matt georgette) was selected as the target thermal screen. The ultraviolet irradiation that reached the target thermal screen specimen (60 x 60cm) was 5mW/cm2. Thus, the ultraviolet irradiance was set to 5mW/cm2, and the exposure periods of accelerated weathering conditions on the specimens were set to 0, 282, 847, and 1412h. The radiation exposure periods of the weathering conditions for 0, 282, 847, and 1412h indicate the amount of ultraviolet accumulation for 0, 1, 3, and 5years, respectively. In the accelerated weathering test, the target specimens that completed each exposure phase were subjected to the hotbox test to analyze their thermal insulation performances. Consequently, the thermal insulation performance of the multi-layer thermal screen was estimated to degrade rapidly after approximately two years. In the accelerated weathering condition, a quadratic function model was used to calculate the expected service life, since it adequately described the variation in thermal insulation of the thermal screen according to time. The results showed that when the thermal insulation performance degraded by 5, 10, 20, and 30%, the expected service lives were 2.5, 3.3, 4.5, and 5.5years, respectively.
        4,000원
        2.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we conducted the hot box tests to compare the changes in thermal insulation for the four types of multi-layer thermal screens by the used period after collecting them from the greenhouses in the field when they were replaced at the end of their usage. The main materials for these four types of multi-layer thermal screens were matt georgette, non-woven fabrics, polyethylene (PE) foam, chemical cotton, etc. These materials were differently combined for each multi-layer thermal screen. We built specimens (70×70 cm) for each of these multi-layer thermal screens and measured the temperature descending rate, heat transmission coefficient, and thermal resistance for each specimen through the hot box tests. With regard to the material combinations of multi-layer thermal screens, thermal insulation can be increased by applying a multi-layered PE foam. However, it is considered that the multilayered PE foam significantly less contributes to heat-retaining than chemical wool that forms an air-insulating layer inside multi-layer thermal screens. For the suitable heat-retaining performance of multi-layer thermal screens, basically, materials with the function of forming an air-insulating layer such as chemical cotton should be contained in multi-layer thermal screens. The temperature descending rate, heat transmission coefficient, and thermal resistance of multi-layer thermal screens were appropriately measured through the hot box tests designed in this study. However, in this study, we took into consideration only the four kinds of multi-layer thermal screens due to difficulties in collecting used multi-layer thermal screens. This is the results obtained with relatively few examples and it is the limit of this study. In the future, more cases should be investigated and supplemented through related research.
        4,000원
        3.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 현장에서 사용되는 온실 강관의 이음 방법에 대해 휨성능을 평가하고 그 결과를 바탕으로 가장 휨성능이 우수한 이음 방법을 알아보았다. 실험 결과, 모든 실험체는 이음이 없는 실험체 보다 휨성능이 작았다. 그러나 모든 실험체의 최대 휨모멘트는 이음이 없는 실험체 소성모멘트의 1.07~1.3정도로 나타났다. 또한 연결 방법에 따른 결과는 연결핀 보다 인발 실험체가 상대적으로 큰 휨성능을 보였다. 현장 이음 방법의 파괴 모드는 연결핀과 강관 끝부분의 응력집중에 의한 국부좌굴이 지배적이었다. 현장시공 시 강관을 절단 후 연결할 경우, 이음 없이 사용하는 것이 가장 우수한 휨성능을 발휘하지만 부득이 강관을 절단할 경우는 연결핀보다는 인발 강관에 직결나사로 고정한 이음 방법(SPJ-F)으로 시공하는 것이 유리할 것으로 판단된다.
        4,000원
        4.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대기오염에 대한 관심은 국내·외에서 점진적으로 상승하고 있으며, 자동차 및 연료 연구자들은 청정(친환경 대체연료) 연료와 연료품질 향상 등을 이용하여 새로운 엔진 설계, 혁신적인 후처리 시스템 등의 연구를 통하여 차량 배기가스 및 온실가스를 감소시키고자 노력하고 있다. 이에 본 연구에서는 각기 다른 차량기술이 적용된 휘발유, 경유, LPG를 연료로 사용하는 7대의 차량을 대상으로 국내·외에서 법적시험모드로 사용되고 있는 도심모드, 고속모드, 급가·감속, 에어컨사용 및 겨울철 특성을 반영한 저온모드에서 온실가스의 배출특성을 확인하고자 하였다. 사용연료에 관계없이 대부분의 온실가스는 저온인 Cold FTP-75 모드에서 가장 안 좋은 결과가 나타나는 경향을 가지고 있다. 각 차량별 온실가스 증가 요인으로는 가솔린 차량인 A차량(2.0 MPI)과 B차량(2.4 GDI)에서는 최고속 및 급가·감속 , 에어컨 사용 , 저온 조건의 순인데 비해 E차량(1.6 T-GDI)은 에어컨 사용, 최고속 및 급가·감속 , 저온 조건의 순이다. G차량 (LPLi)은 에어컨 사용 , 저온 , 최고속 및 급가·감속 조건의 순으로 가솔린 차량과 다른 특성을 가지고 있다. 경유 차량에 있어서는 A차량(2.0 w/o DPF)과 B차량(2.2 w/ DPF)은 최고속 및 급가·감속 , 에어컨 사용, 저온 조건의 순이었고, F차량(1.6 w/ DPF)은 저온, 에어컨 사용, 최고속 및 급가·감속 조건의 순으로 확인되었다. 따라서, 각 연료별로 배출가스 저감 기술을 다르게 적용하여야 효과적인 방법이라고 할 수 있겠다.
        4,300원
        5.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 플라스틱 온실에서 사용하는 죔쇠의 성능 평가 시 시험편 끝단의 구속조건이 미끄럼 저항력에 미치는 영향을 분석하기 위해 시험편 구속조건을 실험변수로 판형죔쇠의 미끄럼 저항력을 측정하였다. 각 구속조건별로 측정한 미끄럼 저항력의 평균값은 서까래 고정-고정단이 가장 컸으며, 내재해형 죔쇠의 평가 기준 값과 비교한 결과에서도 서까래 고정-고정단의 경우에만 기준을 만족하는 것으로 나타났다. 그러나 서까래 고정-고정단 구속조건은 다른 구속조건들에 비해 산 포도가 상대적으로 크게 나타나 신뢰성이 떨어지는 결과를 보였다. 또한, 일원분산 분석결과에서도 서까래 고정- 고정단은 다른 구속조건들과 비교해 미끄럼 저항력이 유의한 차이를 보였다. 따라서 시험편 구속조건이 미끄럼 저항력 평가에 영향을 미친다고 판단하며 연구자 및 기술자들이 죔쇠의 미끄럼 저항력을 측정할 때에는 시험편의 구속조건이 결과값의 신뢰성에 미치는 영향을 면밀히 검토해야 할 것으로 판단된다.