        1.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzes the internal temperature characteristics of heater module using a numerical method when the constant heat flux and heat flux time are applied to the surface heating element. The horizontal and vertical dimensions of heater module are 100mm, and the height is 5mm. The heat flux is 10,000W/m2, 15,000W/m2, and 20,000W/m2, and heat flux time is 5 seconds, 10 seconds, 15 seconds, 20 seconds, 30 seconds and 50 seconds, respectively. When the heat flux time was 50 seconds, the temperature of the surface heating element rose to 120.5°C, while the skin epidermis temperature rose 1.7°C. As a result, the surface temperature of the surface heating element increased greatly in the horizontal direction, while it increased low in the depth direction. This is because the heat conduction of the surface heating element is transmitted in the X-Y plane direction, and the thermal conductivity of the pet(polyethylene terephthalate) film and insulation sheet under the surface heating element is very low. when the heat flux at the surface heating element is 20,000W/m2, the skin's epidermal temperature rises up to 0.82℃ compared to 10,000W/m2 and 15,000W/m2.
        4,000원
        2.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 서로 다른 열전달 특성을 가진 탄소섬유 전기발열체와 경유온풍난방기가 온실 내부의 온습도, 에너지소비, 작물생육 등에 미치는 영향을 분석하기 위해 오이 재배 단동온실에 대한 난방 비교시험을 수행하였다. 전기발열체 온실에서 난방용량이 온실 환경과 난방기 운전에 미치는 영향을 분석하기 위해 온실에 6, 9, 16kW의 전력을 각각 공급한 결과 전기발열체 ON-OFF 주기는 각각 9, 11, 15회로 비례하여 증가하였으며 온실 내부 평균온도는 각각 15.2, 15.3, 15.6oC, 평균상대습도는 84, 81, 76%로 나타나 난방 용량이 클수록 온실내부 온도는 높고, 상대습도는 낮게 나타났다. 또한 6, 9kW 가동 시 하부온도가 상부보다 0.1oC 높았으며 16kW 가동 시는 상부 평균온도가 하부보다 0.2oC 높았다. 전기발 열체와 경유온풍난방기의 비교 시험에서는 난방 시 온실 상부와 하부의 온도차가 전기발열체 온실이 0.1~0.2oC로 경유온풍난방기 온실의 0.5~0.6oC보다 작았으며, 온실 상류와 하류의 온도차는 전기발열체 온실이 0~0.1oC로 경 유온풍난방기 온실의 1.3~1.4oC보다 작아 정밀한 온도관리가 가능하였다. 난방기간 동안 사용한 에너지사용량은 경유온풍난방기 온실이 경유 867L를, 전기발열체 온실이 전력량 8,959kWh를 사용하였으며, 난방비용은 각각 607 천원과 403천원이 소요되어 전기발열체 온실에서 약 34%의 비용절감 효과가 있었다. 전기발열체 온실의 경우 상대적으로 군락 상하부의 환경관리가 균일하여 초장을 비롯한 전반적 생육상황이 경유온풍난방기 온실보다 좋았으나 통계적으로 유의한 차이는 없었으며, 수확량 역시 전기발열체 온실의 작물군락 하부 온도가 경유온풍 난방기 온실보다 1.3oC 더 높게 관리되어 4.3% 증수효과가 있었으나 통계적으로 유의한 차이는 없었다. 원예 시설의 최적 난방 관리를 위해서는 각 난방기의 열전달 특성에 기초하여 난방기 용량, 배치, 열분배 방법에 대한 설계가 요구되며, 전열선 형태의 난방기 역시 작물형상 및 재배방법을 고려하여 전열선의 개수, 위치, 방열 온도 등에 대한 설계가 필요한 것으로 판단되었다.
        4,000원
        3.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is based on the screen printing method with heat resistant thin film as base material and development for expansion is proceeding. Therefore, it is convenient to be applicable to the installation and it will be possible to reduce the cost compared with the existing construction such as heat trace by 50% or more. As a result, it is possible to develop and commercialize the market for Polar ship, shipbuilding and offshore plants as it is possible to secure CNT(Carbon Nano Tube) based surface heating element and heating paste composition technology as a heating element material at a cryogenic temperature. It is expected that the efficiency will be great when this method is applied to other industries.
        4,000원
        4.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Carbon composites for flexible fiber heating element were examined to improve the electrical conductivity in this study. Carbon composites using carbon black, denka black, super-c, super-p with/without CNF or dispersant such as BCS03 and Sikament-nn were prepared. Carbon composite slurry was coated on plane film and yarns(cotton, polyester) and the performances of prepared heating materials were investigated by checking electrical surface resistance, adhesion strength. The plane heating element using carbon black under natural drying condition(25℃) had better physical properties such as surface resistance(185.3 Ohm/sq) and adhesion strength(above 90%) than those of other carbon composite heating elements. From these results, polyester heating element coated by carbon black showed better electrical line resistance(33.2 kOhm/cm) than cotton heating element. Then, it was found that polyester heating element coated by carbon black with CNF(3 wt%) and BCS03(1 wt%) appeared best properties(0.604 kOhm/cm).
        4,000원
        5.
        2015.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        To fabricate porous SiC-Si composites for heating element applications, both SiC powders and Si powders were mixed and sintered together. The properties of the sintered SiC-Si body were investigated as a function of SiC particle size and/or Si particle contents from 10 wt% to 40 wt%, respectively. Porous SiC-Si composites were fabricated by Si bonded reaction at a sintering temperature of 1650 oC for 80 min. The microstructure and phase analysis of SiC-Si composites that depend on Si particle contents were characterized using scanning electron microscope and X-ray diffraction. The electrical resistivity of SiC-Si composites was also evaluated using a 4-point probe resistivity method. The electrical resistivity of the sintered SiC-Si body sharply decreased as the amount of Si addition increased. We found that the electrical resistivity of porous SiC-Si composites is closely related to the amount of Si added and at least 20 wt% Si are needed in order to apply the SiCSi composites to the heating element.
        4,000원
        6.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 피복자재와 전기발열체에 의한 포도 유목의 휴면기와 수액이동기 꽃눈 피해를 경감하기 위하여 수행하였다. 1. 저온 환경제어시스템에서 보온력 차이는 볏짚 +부직포 > 부직포 > 볏짚 > 무피복 순으로 높았으며, 볏짚 +부직포 2중피복에서 온도 저하 지연 효과가 가장 좋았으나, 12시간 처리에서는 피복자재별 보온력 차이가 거의 없었다. 2. 휴면기 꽃눈 피해는 캠벨얼리와 MBA가 비슷하였으며, 거봉에서 높았고, 무피복 > 볏짚 > 부직포 > 볏짚 +부직포 순으로 낮았다. 볏짚 +부직포는 −20℃ 6시간 저온처리부터 꽃눈 피해가 발생하여 보온 효과가 높았다. 3. 수액이동기 –10℃ 저온처리에서 꽃눈 피해는 휴면기와 비슷한 경향이었으며, 품종 간에는 차이가 없었으며, 휴면이타파된 수액이동기 저온에서 꽃눈 피해가 더 크다. 4. 전기발열체 +부직포는 −5℃ 3시간 처리에서 휴면기 –20℃에서 −4.8℃, 수액이동기는 −10℃에서 −4.3℃ 주간부 내부온도가 유지되어 방한에 효과적이었다. 5. 짚 +부직포은 휴면기에는 꽃눈 피해가 발생하는데 지연 효과가 있으나 수액이동기에는 효과가 적었으며, −5℃ 설정 전기발열체 +부직포에서는 꽃눈 피해가 발생하지 않았다.
        4,000원
        7.
        2015.04 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 기존에 사용 중인 X선 발생장치의 촬영대를 따뜻하게 가열하면서도 X선 감약이 적은 탄소나노튜 브(carbon nano tube, CNT) 발열체를 사용하여 가열장치를 구비한 X선 발생장치용 부착형 촬영대의 고안 및 설계를 하고자 한다. 고안된 제품의 구성은 부착형 탄소발열체 촬영대로서 기존 X선 촬영대, 탄소나노튜브 면상발열체, 전극 선, 난연 처방된 보호필름과 바닥필름으로 구성되어 있다. 본 고안 제품의 특징과 장점은 냉기(冷氣)를 느끼는 촬영대 에서 환의를 착용하고 검사를 받는 환자에게 온화한 느낌과 안전감을 제공하고 심적인 불안감을 해소하여 검사에 도움 을 줄 수 있기 때문에 임상 적용을 적극 권장하는 바이다.