In this study, the seismic performance of concrete-steel composite moment frame structures equipped with seismic retrofitting systems such as seismic reinforcement, base isolators, and bracing members, which are typical earthquake damage mitigation systems, is evaluated through nonlinear dynamic analyses. A total of five frame models were designed and each frame model was developed for numerical analyses. A total of 80 ground acceleration data were used to perform the nonlinear dynamic analysis to measure ground shear force and roof displacement, and to evaluate the behavioral performance of each frame model by measuring inter-story drift ratios. The analysis results indicate that the retrofitting device of the base isolator make a significant contribution to generating relatively larger absolute displacement than other devices due to flexibility provided to interface between ground and column base. However, the occurrence of the inter-story drift ratio, which is a relative displacement that can detect the damage of the structure, is relatively small compared with other models. On the other hand, the seismic reinforced frame model enhanced with the steel plate at the lower part of the column was found to be the least efficient.
현행 내진설계기준에서 RBS-B 접합부는 오직 중간모켄트골조(IMF) 시스템에서만 사용이 허용된다. 본 연구는 현행설계규준에 따라 설계한 RBS-B 접합부를 갖는 철골 모멘트골조 시스템의 내진성능평가를 수행하였다. 이를 위하여 층수(3층, 6층, 9층), 경간너비(6m, 9m), 내진설계범주(SDC C_{max}, SDC C_{min})으로 구성된 12개의 RBS-B접합부를 갖는 철골모멘트골조 건물을 설계하였고 RBS-B 접합부의 비선형 이력거동을 잘 모사하는 접합부 모델을 개발하였다. 설계된 대상골조는 ATC-63에 의해 개발된 내진성능평가방법에 따라 내진성능평가를 수행하였다. 또한 본 연구는 저자가 이전연구에서 제안한 새로운 설계법에 따라 설계된 IMF 시스템의 내진성능평가를 수행하였다. 그 결과 현행규준에 따라 설계한 몇 개의 대상골조가 적절한 붕괴여유비를 보유하지 못하였다. 반면에 새로운 설계절차에 따라 설계된 대상골조는 적절한 붕괴여유비를 보유하였다.
철근콘크리트 건축물에서 비내력벽(Masonry Infill Walls)은 내부 칸막이벽이나 중저층 규모의 건물 외벽에 흔히 사용된다. 그렇지만 대부분의 경우에 비내력벽은 비구조체이므로 구조설계시 건물의 모형화에서 무시된다. 따라서 본 연구에서는 비내력벽을 보편화된 모형화 방법인 등가의 대각 압축 스트럿(Equivalent Diagonal Strut)으로 고려하여 비내력벽의 유무에 따른 저층 철근콘크리트 건축물의 전체적인 지진거동의 양상을 평가하고자 하였다. 해석결과로 비내력벽을 고려하면 시스템의 추가적인 강도 및 강성을 확보하여 층간변위비를 줄일 수 있으나 진동주기가 짧아져서 설계단계에서 고려한 지진하중보다 큰 하중을 받게 된다. 연약층이 있는 모델의 경우에는 기둥에 소성거동이 집중됨을 알 수 있으며 부분적인 붕괴가 전체 시스템의 붕괴 원인의 가능성을 가진다.
The seismic performance of a three-story knee-braced moment-resisting frame (KBMRF), which was typically employed to support pipelines for oil or gas, was investigated. Nonlinear static pushover analyses were performed first to observe the force-displacement relationship under increasing seismic load. Then nonlinear dynamic time-history analyses were carried out usingeight earthquake ground motion time-histories scaled to fit the design spectrum of UBC-97. It turned out that the maximum inter-story drift was smaller than the drift limit of 1.5 % of the structure height, and that the columns remained elastic. Based on these analytical results, it can be concluded that the seismic performance of the structure satisfies all the requirements regulated in the seismic code.
The conventional brace system is generally accepted lateral load resisting system for steel structures due to efficient story drift control and economic feasibility by frame materials decrease. But the lateral stiffness of the brace decreases following buckling in this system and buckling causes unstable structures with strength deterioration hysteresis performance. Buckling restrained brace system that performs stable behavior after yielding of core element prevented from buckling by tube element is better than conventional brace system in point of earthquake energy absorbing capacity. In this study, the seismic performance of the multi-story steel frames applied for brace and buckling restrained brace is respectively analyzed, so that, the damage of two systems is quantitatively evaluated by analyzing energy absorption capacity.
In this study, the seismic performance of weak-axis column-tree moment resisting frame was experimentally investigated using RBS conception. As a result, two specimens were showed that enough energy dissipation and plastic rotation capacity. But bolt-slip didn’t happen anymore after story drift ratio of 3%.
In this study, the seismic performance of weak-axis steel moment connections was investigated through cyclic testing of two full-scale specimens by reducing flange plate thickness. As a result, two specimens were showed that enough energy dissipation capacity and ductility.
파랑하중의 입사각의 변화가 직사각형 콘크리트 플로팅 함체 위에 있는 3층 철골 모멘트 연성골조의 모멘트에 미치는 영향을 알아보기 위하여, 파도 주기 5초부터 15초까지 2초 간격으로 동적 유체해석을 수행하였다. 길이방향에 대하여 입사각이 0˚, 30˚, 60˚, 90˚로 증가함에 따라 RAO-Roll에 의한 영향이 증가하는 것으로 나타났다. 파압에 의하여 입사각이 0˚인 경우 길이방향의 골조 모멘트가 크게 증가하였으며, 입사각이 증가함에 따라 파압에 의한 모멘트가 감소하는 것으로 나타났다. 또한 함체의 피칭과 롤링에 의하여 발생되는 가속도 성분에 의하여 상부 철골 모멘트 연성 골조의 모멘트를 산정하였으며, 입사각이 90˚로 작용한 경우에 모멘트의 증가량이 입사각 0˚의 경우보다 크게 나타났다.
플로팅 함체의 강성변화가 상부 철골모멘트연성골조에 미치는 영향을 확인하기 위해 함체의 높이를 1.5m, 2.0m, 2.5m로 변화시키면서 파랑하중 3초에서 15초에 대하여 동적 유체 해석과 그에 따른 파력을 산정하고 정적 구조 해석을 수행하였다. 해석결과, RAO-피치와 상부 골조의 모멘트 증가량이 선형적인 관계이고 함체의 곡률이 구조물의 강성과 반비례함을 확인하였다. 이러한 선형적 결과를 종합하여, 임의의 함체에 대한 상부골조의 해석 결과를 이용하여 함체 높이가 다른 경우에도 상부 골조의 모멘트를 추정하는 절차를 제안하였으며, 추정결과가 해석결과와 상당히 잘 일치함을 확인하였다.