This study focuses on analyzing the energy-saving effects of the recirculation aquaculture system using seawater source heat pumps and solar power generation. Based on the thermal load analysis conducted using the transient system simulation tool, the annual energy consumption of the recirculation aquaculture system was analyzed and the energy-saving effects of utilizing the photovoltaic system was evaluated. When analyzing the heat load, the sea areas where the fish farms are located, the type of breeding tank, and the circulation rate of breeding water were taken into consideration. In addition, a method for determining the appropriate capacity for each operation time was examined when applying the energy storage system instead of the existing diesel generator as an emergency power, which is required to maintain the water temperature of breeding water during power outage. The results suggest that, among the four seas considered, Jeju should be estimated to achieve the highest energy-saving performance using the solar power generation, with approximately 45% energy savings.
"Are we alone in the universe?" is the fundamental question of mankind. To search for the life signaturesin the universe, there have been a lot of researches and space explorations, especially in our solar system. In this review paper, we introduce the de nition and characteristics of the \biosignature". The currentsituations and future plans for searching for biosignatures in our solar system are reviewed, especially atVenus, Mars, and Ocean Worlds such as Europa and Enceladus where life signatures are more likely toexist than in other places in the solar system. Finally, we discuss the opportunities and strategies for theKorean scienti c society to participate in searching for biosignatures in the solar system.
우리나라 딸기 재배는 시설 재배로 이루어지고 있으며, 대부분 농가의 급액 관리는 재배자의 경험을 토대로 타이머 제어 방식으로 이루어지고 있다. 타이머 급액 방법은 재배 환경, 작물의 생육 단계, 배지 수분 함량 등을 고려하기 어려워 작물을 최적 수준으로 관리하지 못하고, 급액 관리의 정확성이 결여되는 문제점이 있다. 적산 일사량과 배지 수분함량을 이용한 급액 방법은 작물의 생육 상태에 따라 정밀하게 양액을 공급하는 친환경적인 방법이다. 본 연구는 코이어배지를 이용 한 딸기 수경재배에서 적산일사량과 배지 수분함량을 이용한 복합 급액 제어와 타이머 제어 급액 방법을 비교하고 복합 급액 제어 시 최적의 적산 일사량 기준을 설정하고자 수행하였다. 적산일사량 급액 방법은 외부 일사량을 기준으로 100, 150, 250J∙cm -2에 도달하면 자동으로 급액하며 배지 수분함 량이 60% 미만이면 강제 급액하고, 1회 급액량은 50mL로 공급하였다. 타이머 제어는 대조구로 설정하였다. 급액을 개시 하는 적산 일사량 기준이 작을수록 일일급액량이 많았으며 100J∙cm -2 기준 급액 시 급액량은 250J∙cm -2 처리구 대비 46% 많았다. 지상부 생체중과 건물중 모두 복합 급액 제어 방법이 타이머 제어보다 높았으며, 100, 150J∙cm -2 처리구에서 지상부 생체중이 높았고 100J∙cm -2 처리구에서 건물중이 유의하게 높은 값을 나타냈다. 수량 또한 타이머 제어 방법보다 복합 제어 방법에서 유의하게 높았으며 적산 일사량 기준이 작을수록 초기 수량이 증가하였다. 평균 과중은 타이머 제어 급액 시 가장 낮았다. 본 연구 결과 딸기의 정밀 급액 관리를 위하여 적산 일사량과 배지 수분 함량 센서를 이용한 복합 제어 활용 가능성을 확인하였다.
We study the photometric phase curves for the planets of our solar system which can be considered as a prototypical non-compact planetary system. We focus on modeling the small variations caused by three effects: reflection, ellipsoidal, and Doppler beaming. Theoretical predictions for these photometric variations are proposed, considering a hypothetical external observer. Unlike similar studies of multi-planetary systems, the physical and geometrical parameters for each planet of the solar system are well-known. Therefore, we can accurately evaluate the relationships that shape the planetary light curves for a fictitious external observer. Our results suggest that, for all planets, the ellipsoidal effect is very weak while the Doppler beaming effect (DBE) is, in general, dominant. In fact, the DBE seems to be the principal cause of variations of the light curves for the planets of the solar system. However, for Mercury and Venus the Doppler beaming and reflection effects have similar amplitudes. The phase curves obtained for the planets of the solar system show new interesting features of interest for the study of other non-compact planetary systems.
In this study, we developed a learning progression for the structure of the solar system using multi-tier supply form items and validated its appropriateness. To this end, by applying Wilson’s (2005) construct modeling approach, we set up ‘solar system components,’ ‘size and distance pattern of solar system planets,’ and ‘solar system modeling’ as the progress variables of the learning progression and constructed multi-tier supply form items for each of these variables. The items were applied to 150 fifth graders before and after the classes that dealt with the ‘solar system and star’ unit. To describe the results of the assessment, the students’ responses to each item were categorized into five levels. By analyzing the Wright map that was created by applying the partial credit Rasch model, we validated the appropriateness of the learning progression based on the students’ responses. In addition, the validity of the hypothetical pathway that was established in the learning progression was verified by tracking changes in the developmental level of students before and after the classes. The results of the research are as follows. The bottom-up research method that used multi-tier supply form items was able to elaborately set the empirical learning progression for the conceptualization of the structure of the solar system that is taught in elementary school. In addition, the validity of the learning progression was high, and the development of students was found to change with the learning progression.
We investigate the provenance and the changes in the timekeeping system focusing on official records such as almanacs and textbooks published by the government after the solar calendar was introduced. We found that the solar calendar and the 12-hour clock time first appeared in 1884 during Joseon dynasty, at that time the solar calendar was used at the open port in Busan to facilitate the exchanges with Japan. The 12-hour clock time first appeared in the『Hansung Sunbo』published by the government in 1884. We also found that the Joseon dynasty also used 12 diǎnzhōng or 12 diǎn. In addition, the term of the ‘Sigan’ first appeared in the first official academic textbook in August 1895, and the chapter related to time contained the information about 12-hour clock time instead of the 12 Shi. In 1908, the meaning of the solar time, the equation of time, and the differences in longitude with the adoption of Korean Standard Time were introduced. Meanwhile, the 24-hour clock time was first introduced in Joseon and applied to railway times in 1907. The 1946 almanac, the first issue after liberation, used the 12-hour clock time which uses ‘Sango’, ‘Hao’ and the 24-hour clock time started to be used from the following year and is still used to this day. Finally, the 12-hour clock time, which was introduced around 1884, was enacted as Article 44 of the law in 1900 and was revised again in 1905 and 1908. In Korea, the terms related to the time in the current astronomical calendar system were newly defined around 1884, 1896, and 1908, and gradually standardized through the establishment of laws.
PURPOSES : The purpose of this study is to develop a solar powered block pavement system satisfying the road design criteria in Korea. The concrete block pavement system was chosen as the most suitable for development at the current level of technology.
METHODS : A new solar block pavement system was conducted by seperating the solar module from the concrete block. The solar panel module is responsible for the solar powered system and the solar concrete block is responsible for the vehicle load support. Quality criteria for block pavements in Korea were collected to select the appropriate quality criteria for a solar block pavement system. The laboratory tests conducted were slip resistance test, compressive strength test and absorption rate test of the concrete blocks, flexural strength test of the acrylic protection panel, and UTM load test of the solar panel module. Solar power measurement was also conducted at the field test section for field performance evaluation.
RESULTS : The acrylic protection panels were selected as 15mm thick panels with diagonal patterns of 45°, considering the power generation efficiency, appropriate thickness of the solar power modules, slip resistance and flexural strength. The results of the laboratory tests for evaluating the structural performance of concrete blocks demonstrated that the compressive strength and absorption rate were 22.7 MPa and 3.4% on average, respectively. From these results, it can be observed that the concrete blocks of the solar block pavement system satisfy the block pavement criteria in Korea. As a result of the UTM load test of the solar panel module, the maximum compressive load was found to be 26 tonf on average, and it was confirmed that damage does not occur under a passenger car load.
CONCLUSIONS : A new solar block pavement system was developed by seperating the solar module and concrete block. As a results of the laboratory and field tests, both the solar module and concrete block satisfied the quality criteria for block pavement in Korea.