검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 288

        161.
        2007.03 구독 인증기관 무료, 개인회원 유료
        The behavior of the Tuned Liquid Damper (TLD) which has been widely used for mitigating structural vibration is generally modeled by linear wave theory and its vibration control performance is evaluated using Tuned Mass Damper (TMD) analogy. However, some previous studies showed that the properties of the TLD such as natural frequency and damping ratio were dependent on the excitation amplitude. In this study, the dynamic nonlinear characteristics of the TLD are investigated by shaking table test with varying excitation amplitude. In case of harmonic excitation experimentation, the damping ratio, natural frequency, and effective mass are obtained through envelope curves overlap of time-history curve from measured base shear and analogy base shear using simulation a freedom of simple degree modeling. In the white noise experimentation, the parameters obtained through curve-fitting of the transfer function from the table acceleration to the base shear.
        4,000원
        162.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는, 동조액체감쇠기(이하 TLD)만을 실험적 부분구조로 이용하여 TLD가 설치된 건축구조물의 지진 응답 제어효과를 평가하기 위한 실시간 하이브리드 실험법을 제안하고 진동대 실험을 통해 실험적으로 규명한다. 제안된 실험법에서, TLD가 설치된 전체구조물은 상부의 TLD와 하부의 구조물 부분으로 각각 실험적 그리고 수치해석적 부분구조로 나누어진다. 이때 부분구조 사이의 경계면에서 작용하는 하중 또는, TLD에 의한 제어력은 진동대에 설치된 전단형 로드셀에 의해 계측되며 진동대는, 계측된 경계면에서의 제어력이 상부에 작용하고 또한 동시에 기초에 지진하중이 작용하는 수치해석적 부분구조로부터 계산된 응답으로, 상부에 설치된 TLD를 가진하게 된다. 제안된 실험법에 의한 결과와 TLD와 건물모델 모두를 제작하여 실험하는 기존의 방법에 의한 실험 결과들은 서로 잘 일치하며, 이로써 본 논문에서 제안된 실험법을 이용하여 TLD의 제어성능을 손쉽게 평가 할 수 있음을 알 수 있다.
        4,000원
        163.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강제 진동 실험은 구조물의 수학적 모델과 실제 모델의 상관관계를 입증하여 구조물의 성능을 정확히 평가하기 위해 중요하기 때문에, 동적 및 정적 가진 실험을 통해 구조물의 내진성능을 평가하는 다양한 기법이 사용되고 있다. 본 논문에서는 복합 질량형 감쇠기(Hybrid Mass Damper, HMD)를 이용하여 지진하중을 모사하는 실물크기 철골조 구조물의 강제진동실험이 수행되었다. ANSYS를 사용하여 구조물의 유한요소 해석모델을 구축하였고, 강제진동 실험을 통해 얻은 계측데이터를 사용하여 이 해석모델을 갱신하였다. 의사 지진 가진 실험은 HMD에 의해 유도된 층응답이 실험을 통해 갱신된 유한요소모델을 사용한 수치해석 응답과 일치함을 보여준다.
        4,300원
        164.
        2006.12 구독 인증기관 무료, 개인회원 유료
        In Oriental Medicine, Atopic dermatitis(AD) belongs to the category of the Naesun, Taesun(胎癬), Taeryumchang(胎斂瘡), Eczema(濕疹), Seupchang(濕瘡), Samanpung(四彎風), Chimumchang(浸淫瘡). The Basic Prescriptions which have been used for treatment of Atopic dermatitis are saengryusamultang(生料四物湯), Onchungeum(溫淸飮), Seungmagalgeuntang(升麻葛根湯),Hoichunryangkyuksan(回春凉膈散), Doghengsan(導赤散), Pyungweesan(平胃散), Heungbangpaedoksan(荊防敗毒散), Goomigangharltang(九味羌活湯), Baekhotang(白虎湯), Gaegytang(桂枝湯), Yukmigihyuangtang(六味地黃湯). AD can divide three groups, Acute-Type, Semiacute-Type, Chronic-Type, according to it's condition. This study shows that it can be applicate Seungmagalgeuntang(升麻葛根湯), Hoichunryangkyuksan(回春凉膈散), Doghengsan(導赤散), Heungbangpaedoksan(荊防敗毒散), Goomigangharltang(九味羌活湯), Baekhotang(白虎湯), Gaegytang(桂枝湯) for treatment of Acute-Type, Pyungweesan(平胃散) for treatment of Semiacute-Type, and saengryusamultang(生料四物湯), Onchungeum(溫淸飮) for treatment of Chronic-Type.
        4,600원
        165.
        2006.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Amorphous carbon nanotubes were synthesized by a reaction of benzene, ferrocene and Na mixture in a small autoclave at temperatures as low as . The resulting carbon nanotubes were short and straight, but their inner hole was filled with residual products. The addition of quartz to the reacting mixture considerably promoted the formation of carbon nanotubes. A careful examination of powder structure suggested that the nanotubes in this process were mainly formed by surface diffusion of carbon atoms at the surface of solid catalytic particles, not by VLS(vapor-liquid-solid) mechanism.
        4,000원
        167.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는, 지진하중에 의해 구조물에 발생하는 진동을 제어하기 위하여 토글 시스템의 비선형성을 연구하고, 자기유변유체(MR) 감쇠기를 장착한 토글 가새시스템의 성능을 평가하였다. Bingham 모델로 표현되는 MR감쇠기의 제어력이 속도의 함수인 점을 고려하여, 토글 가새시스템에 의한 속도증폭계수를 계산하였고 토글 형태에 대한 증폭계수효과를 평가하였다. 특히 강한 지진하중에서 쉐브론과 대각가새 등의 전형적인 가새시스템에 장착된 MR감쇠기가 충분한 응답감소효과를 제공하지 못하는 경우에, 토글 가새시스템을 사용하여 제어성능을 크게 강화시키는 것을 수치해석 결과를 통하여 확인하였다.
        4,000원
        168.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis of TMD to estimate optimal-design-parameter is investigated using actual excitation, and evaluated by comparing results of numerical analysis and optimal-design-parameter was devised by Soong. It assumed between 1~2 seconds the 1st mode natural period of an aged apartment which has 10~15 stories and then investigated optimal-design-parameter of actual excitation for evaluate optimal frequency ratio and damping ratio according to local site condition. At this time mass ratio was 1% and range of tuned frequency ratio was 0.8Hz to 1.2Hz at intervals of 0.01Hz, and optimal damping ratio was 1% to 14% at intervals of 0.002%. It estimated Optimal-design-parameter was evaluated by numerical analysis according to peak and RMS displacement, acceleration respectively local site. And the result of evaluated respond performance parameter respectively a period was shown low numerical-value than optimal-design-parameter was devised by Soong what is more peak acceleration indicated performance difference of 20% over
        4,000원
        169.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In this study, the vibration control performance of Tuned Liquid Damper(TLD) with nonlinear properties is investigate by a with shaking table test according to large excitation. Until recently, TLDs has been investigated by behavior of liquid using equivalent TMD analogy and liner wave theory. The properties of TLDs assumed immutable but became generally known as a matter of fact TLDs behavior has a nonlinear properties that change the TLDs characteristics according to excitation. It was measured base shear and wave height in water tank at 0.01g to 0.06g as 0.01g intercals and tuned 0.6Hz, 0.8Hz. The result of shaking table test showed trend decreased amplification ratio of base shear and wave height as more increased peak accelearation of vibration, what is more jump frequency that dependent excitation dimension.
        4,000원
        170.
        2006.02 구독 인증기관 무료, 개인회원 유료
        In this study, in order to investigate the effectiveness of tuned liquid damper (TLD) for the seismic performance enhancement of the existing reinforced concrete (RC) apartment structure which is not seismically designed, shaking table test was conducted for the small scale five story RC structure with TLD. TLD model was constructed to have the frequency tuned to the first modal frequency of the structure, 2% mass ratio of the first modal mass, and 0.08 liquid depth ratio. White noise with 0.2~5Hz frequency bandwidth and harmonic load tests were performed using the shaking table at Korea Institute of Machinery and Materials, and the displacement and absolute acceleration of each floor were measured. Test results indicate that more than 30% seismic responses reduction can be achieved using TLD for RC structure under white noise and harmonic load.
        4,000원
        171.
        2006.02 구독 인증기관 무료, 개인회원 유료
        The apartment structures built using tunnel form method in 1980's, are vulnerable to lateral loads since wall elements don't exist in longitudinal direction and especially they were not seismically designed. In this study, in order to evaluate the seismic performance of those apartment structures, nonlinear analysis was performed and static test was conducted using small scale partial specimen. Both shear and moment should be considered for the structure subject to lateral load. Most existing methods, however, consider only shear force in test specimen because it is difficult to realize the actual moment distribution of the practical structure, and furthermore axial force is often neglected. This study propose a testing method which can realize similar moment and axial force distribution of a specimen to that of the practical structure by controlling the lateral loading condition. Numerical analysis was performed using moment-curvature curve considering stiffness degrading parameter, ductility-based strength and energy dissipation. The result of this study shows that only 15~20% difference exist between analysis and test, which confirms that the performance of wall elements in a non-seismically designed wall type reinforced concrete apartment can be accurately evaluated.
        4,000원
        172.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 지진하중을 받는 탄성구조물을 대상으로 층전단력 분포에 기초한 마찰감쇠기의 설계방법을 제시하였다. 먼저 마찰감쇠기의 슬립하중(slip-load)을 정규화하는 방법 별로 단자유도 시스템의 수치해석을 수행하고 비교하였다. 이를 통해 슬립하중과 가새 강성의 영향을 파악하였으며, 설치용 가새와 원구조물의 최적강성비를 찾았다. 다음으로는 다양한 고유주기와 층수를 갖는 구조물을 대상으로 수치해석을 통해 마찰감쇠기의 설치 층수와 위치의 결정방법 및 슬립하중의 분배 방법을 도출하였다. 이 과정에서 설치 층수가 포함된 성능지수를 사용하여 슬립하중의 총합으로부터 최적의 설치 층수를 도출하는 경험식을 제시하였다. 마지막으로 실제 지진하중을 사용한 수치해석을 통해 기존의 최적설계 방법과 비교하여 제안된 방법의 우수성을 입증하였다.
        4,000원
        173.
        2005.10 구독 인증기관·개인회원 무료
        174.
        2005.08 구독 인증기관 무료, 개인회원 유료
        In this study, a seismic design methodology for a friction damper based on the story shear force of an elastic building structure is proposed. First, using two normalization methods for the slip-load of a friction damper, numerical analyses of various single-degree-of-freedom systems are performed. From those analyses, the effect of the slip-load and brace stiffness was investigated and the optimal stiffness ratio of the brace versus original structure was found. Second, from the numerical analysis for five multi-story building structures with different natural frequency and the number of story, reasonable decision method for the total number of installation floor, location of installation and distribution of slip-loads are drawn. In addition, an empirical equation on the optimal number of installation floor is proposed. Finally, the superiority of the proposed method compared to the existing design method is verified from the numerical analysis.
        4,200원
        175.
        2005.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문의 목적은 구조물의 지진응답제어를 위해 사용되는 MR 감쇠기의 성능을 선형화기법을 이용하여 등가의 선형 점성으로 표현하고, 이를 MR감쇠기가 설치된 축소건물에 대한 시스템식별 실험을 통해 얻은 결과와 비교하여, MR 감쇠기의 성능평가에 대한 선형화 기법의 타당성을 검증하는 것이다. 먼저, MR 감쇠기의 이력모델로 많이 사용되는 모델 중, 수학적 표현이 간단한 Bingham 모델에 등가선형화 기법을 적용하여 등가의 점성을 구하였다. 그리고, 진동대 가진실험을 통해 얻어진 MR감쇠기가 설치된 3층 소형구조물의 전달함수로부터 모드정보를 추출하고 이를 사용하여 구조물의 점성행렬을 구하였다. 선형화기법을 통해 Bingham 모델을 사용하여 예측된 점성과 실험을 통해 얻어진 MR감쇠기에 의해 증가된 점성은 5% 오차범위 이내로 일치된 결과를 보여준다.
        4,000원
        176.
        2005.02 구독 인증기관 무료, 개인회원 유료
        In this paper, various dynamic model of magnetorheological (MR) damper, is required for describing the hysteresis of MR damper and for their application are investigated to structural control. The dynamic characteristics and control effects of the modeling methods for MR dampers such as Bingham, biviscous, hysteretic biviscous, simple Bouc-Wen, Bouc-Wen with mass element, and phenomenological models are studied. Of these models, hysteretic biviscous model which is simple and describes the hysteretic characteristics, is chosen for numerical studies. The capacity of MR damper is determined as a portion of not the building weight but the lateral restoring force.
        4,000원
        177.
        2005.02 구독 인증기관 무료, 개인회원 유료
        The purpose of this paper is to evaluate the performance of a MR fluid damper for seismic vibration control of a structure in terms of equivalent linear damping or stiffness based on linearization technique and to experimentally verify the results from linearization technique by comparing them to those from system identification of a building structure with MR damper. First, among the various models for MR damper, the equivalent stiffness and damping are estimated for Bingham model which is mathematically simple and for Bouc-Wen model which can describe any kind of hysteretic behavior. Second, transfer function of a building structure with MR damper is obtained by performing shaking table tests and the stiffness and damping matrices of the structure are constructed using the modal information obtained by the transfer function. It is observed that the damping mathematically estimated using linearization technique for Bingham model matches well with the damping coefficient experimentally obtained by system identification.
        4,000원
        178.
        2005.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문의 목적은 탄성과 비탄성 구조물의 지진응답제어를 위한 마찰감쇠기의 설계절차를 제시하는 것이다. ATC-40과 ATC-55를 이용하여 비탄성 구조물의 등가선형감쇠비와 등가선형주기를 구하였고, 이에 기초하여 목표 성능을 만족하기 위한 마찰감쇠기의 최대마찰력을 결정하는 식을 제시하였다. 이 식은 항복 전후 강성비와 요구되는 탄성강도에 대한 항복강도비, 그리고 구조물의 주기에 따라 비선형 수치해석과 오차가 발생한다. 수식에 의해 산출한 최대마찰력과 비선형 수치 해석에 의해 산출된 값과의 오차를 줄이기 위하여, 최소 제곱법을 사용하여 오차 보정식을 제시하였다. 수치해석결과는 제안된 보정식을 사용하면 탄성 및 비탄성 지진응답제어를 위한 마찰감쇠기의 설계를 합리적으로 수행할 수 있음을 보여준다
        4,000원
        179.
        2004.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 에너지소산 제어알고리듬의 제어이득 산정에 관하여 연구하였다. Lyapunov안정성이론에 기초하여 속도 되먹임 포화제어알고리듬, 뱅뱅제어 알고리듬 그리고 에너지게인 제어알고리듬을 제안하였고, 이 알고리듬의 성능을 평가하고 비교하였다. 속도 되먹임 포화제어알고리듬과 에너지게인 제어알고리듬에서는 포화현상을 고려하였고, 뱅뱅제어에서는 경계층을 이용하여 채터링현상을 고려하였다. 수치적인 해석을 통해서 제안된 제어알고리듬이 바람하중에 의해 야기되어지는 구조물의 에너지를 효과적으로 소산시킬 수 있음을 보여주었다.
        4,000원
        180.
        2004.12 구독 인증기관 무료, 개인회원 유료
        This study aims at making a basic data in order that the physical education teachers in high school help the students'positive participation in the lesson and help them learn an active exercise function, by an analysis of the difference of the factors and
        5,200원