        321.
        2013.04 서비스 종료(열람 제한)
        This study aims to investigate basic requirements for adopting the Building Information Modeling(BIM) technology to CO2 monitoring system of building maintenance. This study is progressed to emphasis to utilize BIM building information to estimate amass of CO2 on the maintenance stage. The main purpose of this monitoring technology suggest the effective use of information which enable to efficient evaluation technology.
        322.
        2013.04 서비스 종료(열람 제한)
        This study proposed simplified design procedure of friction damper for enhancing structural seismic performance. Friction damper has a nonlinear characteristic as performing stick and slip motion. So that reason, design of friction damper is difficult. For easy design of damper, first, equivalent damping ratio of the friction damper is derived. Second, design procedure is proposed by the equivalent damping ratio. Finally, seismic performance of structure installed with the friction damper is verified by five earthquake data.
        323.
        2013.04 서비스 종료(열람 제한)
        To evaluate the post-earthquake damage status of URM buildings in Korea, damage state level from the Earthquake Disaster Response System is classified and static test results of 20 URM walls, dynamic test results of 1 URM building are analyzed. From the analysis results, damage state, maximum story drift ratio and residual story drift ratio regarding to the each damage state level are suggested.
        324.
        2013.04 서비스 종료(열람 제한)
        Vibration measurements were conducted before and after the experiment of static loading test for soil-wall in wooden structures. As a result, natural period was changed depending on the damage of soil-wall. Accordingly, the damage assessment was carried out using each specimen strength degradation and the dynamic characteristics.
        325.
        2013.04 서비스 종료(열람 제한)
        This study is on the correlation between the capacity of the city, and floor area of super-tall buildings. Land use affects on a floor area by use of super-tall buildings, and amenities and public facilities affects too. As a result, the appropriate size of the super-tall buildings on the capacity of the city will help in the development of the district region.
        326.
        2013.04 서비스 종료(열람 제한)
        In this study, the case of the seismic evaluation and retrofit for domestic masonry building, which are applied to the house for the aged in Busan city, was introduced. Seismic evaluation can be decided by comparing the seismic capacity index(Is) with the seismic protection index(Iso). According to the seismic evaluation, the seismic retrofit using metal lath and steel plate retrofit method was applied to the case of the lack of the seismic capacity. As a result of the retrofit, the seismic capacity was improved.
        327.
        2013.03 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 건축물의 실시간 피드백 진동제어를 위한 기초연구로써, 자체 기술력을 바탕으로 개발된 무선 가속도센서 시스템 및 프로토타입 (Prototype) AMD 시스템을 결합하여 피드백 진동제어 시스템을 구성하고, 모형 건축물을 대상으로 구성된 제어시스템의 기초성능을 평가하고자 하였다. 이를 위하여 본 논문에서는 우선 MEMS 센서 소자 및 블루투스 통신 모듈 기반의 무선 가속도 센서 유닛, 실시간 가속도 응답획득 및 제어법칙에 근거한 제어출력을 구현하도록 구성한 운영프로그램 등을 개발하였다. 또한 AC 서보모터를 이용해 기동되도록 설계한 프로토타입 AMD 및 모터 드라이버 시스템을 구성하였다. 마지막으로 이를 이용해 실시간 피드백 진동제어 시스템을 구성하였고, 2층 모형 건축물을 대상으로 실험실 규모의 진동제어 실험을 수행하여 목적된 구조물의 진동저감 효과를 정량적으로 분석하였다. 실험의 결과, 모형 구조물의 1차 및 2차 공진주파수 그리고 랜덤주파수 등의 실험조건에서 명확한 진동저감의 효과를 확인할 수 있었으며, 종국적으로 본 논문에서 개발한 무선 가속도센서 시스템 및 AMD 시스템이 향후 여타 구조물의 진동제어를 위한 효과적인 수단으로 응용될 수 있는 가능성을 확인하였다.
        328.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings with reconstruction and reusing in the declined residential area of Jeonju old town. The average CO2 emission to square meter of residential buildings in Jeonju is 1.7tCO2/m2.
        329.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings with reconstruction and reusing in declined commercial area of Jeonju old town. The average CO2 emission to square meter of commercial buildings in Junju is 1.4tCO2/m2.
        330.
        2012.11 서비스 종료(열람 제한)
        This study presents the seismic evaluation and prediction of post-retrofitted piloti-type reinforced concrete building with buckling-restrained braces (BRBs) under the successive earthquakes. For seismic assessment before and after retrofit of the BRBs, the fragility analysis is considered. The fragility relationships for the damaged building between ground shaking intensity and damage probability were derived under the successive earthquakes.
        331.
        2012.11 서비스 종료(열람 제한)
        The aim of this study is to evaluate performance of snow-resistant for the existing building. For this purpose, it was to propose a way to evaluate whether facilities reach goal performance as performance level separated by immediate occupancy level and collapse prevention level. Preliminary evaluation was developed to conduct by using assessment index of five items of vulnerability and two items of impact for selecting the reinforcement priority of target facilities.
        332.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings on the operation phase in the declined residential area of Jeonju old town. The average CO2 emission to square meter of residential buildings in jeonju was calculated.
        333.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cacer risks(ELCRs) in asbestos-containing buildings for maintenance and management. The range of airborne asbestos concentration of 33 buildings was 0.0018 ~ 0.0126 f/cc and one site exceeded indoor air-quality recommended limit 0.01 f/cc. And ELCRs based on US EPA IRIS(Integrated risk information system) model are 1.5E-06 ~ 3.9E-05 levels, and there was no site showed 1.0E-04 (one person per million) level or more, and 11 sites showed 1.0E-05 (one person per 100,000 people) level or more. To prevent the release of asbestos fibers, it needs operation and maintenance of asbestos-containing building materials, and there are some methods such as removal, repairment, enclosure and encapsulation. In conclusion, a risk-based air action level for asbestos in air is an appropriate metric for asbestos-containing building management.
        334.
        2012.08 KCI 등재 서비스 종료(열람 제한)
        최근 해상을 비롯한 수상공간에 다양한 플로팅 건축물이 계획되거나 설치되고 있다. 그러나 관련 법제도의 미비로 인하여 플로팅 건축물의 설계 및 건설 혹은 관리운영에서 많은 문제점이 발생되고 있으며 이는 플로팅 건축물의 활성화를 저해하는 중요한 요인이 되고 있다. 따라서 본 연구에서는 플로팅 건축물에 대한 국내 법제도 적용 사례 및 해외 관련 법제도 사례 조사를 실시하여 우리나라에서 플로팅 건축물의 법제도 개선을 위한 기초자료와 개선방향을 제시하였다. 연구결과 플로팅 건축물은 선박이 아닌 건물로서 법적 지위를 확보하며 플로팅 건축물 설치 특별구역을 설정하여 건물의 대지를 조성하고 별도 기술기준을 적용하며 건축인허가 및 등기 절차를 활용할 수 있도록 법제도 개선이 필요하다.
        335.
        2012.04 KCI 등재 서비스 종료(열람 제한)
        마리나클럽을 중심으로 한 마리나는 앞으로 예상되는 해양관광 및 해양레포츠 수요에 대비한 필수적인 시설이다. 국내 여건을 반영하여 마리나와 마리나클럽은 요트수용 대수를 기준으로 한 규모와 프로그램에 따라 레포츠소형, 복합소형, 레포츠중형, 복합중형, 레포츠대형, 복합대형의 6가지 유형으로 구분할 수 있다. 서울마리나, 아라마리나, 전곡마리나 등 3개의 국내 마리나클럽을 분석한 결과 마리나전용 시설과 상업시설의 공간 비율은 평균 21% : 79% 로 나타났다. 단기적으로는 현재의 공간 구성을 유지하는 방향으로 복합형 마리나클럽 계획이 우선 시 될 것으로 예상되며, 장기적으로는 마리나전용시설 비율이 높은 레포츠형 마리나클럽으로 전환될 것으로 보인다. 또한 플로팅 마리나클럽은 해양관광 및 해양레포츠 체험을 극대화하는 친수공간 확보에 매우 유리하다.
        336.
        2012.02 서비스 종료(열람 제한)
        한반도는 지리적으로 주변국보다는 지진재해의 빈도가 비교적 적은 지역으로 인식되어 있지만, 지진 발생 빈도수가 점차 증가함에 따라 지진재난으로부터 국민의 생명과 재산을 보호하기 위한 방재대책이 필요한 시대적인 요구에 직면해 있다. 이를 대비한 시스템으로 현재 소방방재청에서는 지진재해대응시스템을 구축·운영 중이다. 이번 연구에서는 기존 지진재해대응시스템에 추가적으로 적용할 수 있는 지진재해로 인한 사회 경제적 피해예측 모델 적용을 위한 지진재해대응시스템의 방법론과 관련된 연구를 진행하고자 하였다. 피해예측 모델을 적용하기 위해서는 먼저 지진피해평가기법을 완성하여야 하는데, 이를 위해 지진기록 뿐만 아니라 지진피해에 대한 다양한 현장조사 기록 및 기초 자료들이 필요하다. 하지만 국내에는 이와 같은 기초자료서 활용가능 기본 데이터베이스의 구축이 자료의 양은 적지 않으나, 오래된 자료가 많고 이번 연구에 적용가능의 활용도가 떨어지는 경우가 많다. 지진재해대응시스템에 응용하기 위해 기초자료로서 사용되는 지진가속도자료 또는 토양층 정보, 전단파 속도자료 데이터베이스 정보 등을 선별하여, 최대지반가속도 또는 스펙트럴 가속도 등을 구하는 경험식에 적용하고자 하였다. 또한, 현재 소방방재청에서 진행 중인 지진가속도계측자료통합관리시스템의 산출물인 가속도 정보를 향후에 지진재해대응시스템의 기초자료로서 사용할 수 있는 방안을 설계단계에서 고려하는 연구를 진행 중이다. 이를 통해 해당분야의 적용연구에 대한 선행연구로 이용될 수 있을 것이다.
        337.
        2012.02 서비스 종료(열람 제한)
        화재시 인명 등 피해를 최소화하기 위하여 건물 주요 구조부는 일정 성능의 내화구조로 시공되어야 하며, 이러한 내화구조로 구성된 방화구획 등에는 재실자의 이동, 설비류 시공 등을 위한 개구부가 설치되게 된다. 이러한 개구부에는 화재시 건물내의 연소확대 방지를 위하여 방화문, 방화셔터, 방화댐퍼 등과 같은 연소확대방지설비가 설치되는데 건물에서의 연소확대는 주요구조부의 붕괴 보다는 이와 같은 개구부를 통해 이루어지므로 설치되는 방화문 등 연소확대방지설비에 대한 기준의 정비 및 보완이 중요하다. 연소확대방지설비 중 방화문의 경우 외국에서는 방화문이 설치되는 부위의 내화성능 등을 고려하여 내화성능을 20분에서 최대 3시간까지 구분하여 적용하고 있으나 현재 국내에서는 설치하는 모든 방화문에 대하여 일률적으로 비차열 1시간 성능만을 적용토록 하고 있어 화재발생시에 충분한 연소확대방지를 기대하기 어려운 실정이다. 이에 외국의 방화문 성능기준을 검토하여 국내 방화문의 성능기준을 개선방향과 이를 위한 기초자료를 제공하고자 하였다. 본 연구의 결과 현재 국내의 방화문에 대하여 설치부위의 내화성능 및 설치용도를 감안한 차열성능의 추가, 피난계단·특별피난계단의 부속실로 통하는 출입구·샤프트·피난 통로 등에 설치하는 방화문에 대한 이면상승온도 제한 및 방화문에 사용하는 유리창 면적 제한 및 평가 등에 대한 검토 및 보완이 필요한 것으로 나타났다. 이에 따라 화재시나리오를 바탕으로 한 성능설계, 이에 대한 실제 내화성능 평가 등을 통한 성능검증 등을 실시한 후 이를 바탕으로 구체적인 성능기준 등 제도개선안을 마련하고 전문가 의견 등을 수렴하여 방화문 성능기준에 대한 제도개선이 이루도록 할 것으로 판단되었다.
        338.
        2012.02 서비스 종료(열람 제한)
        재해나 재난으로 인하여 건축물에 발생하는 경제적인 피해규모는 건축물에 내재된 현존가치의 손실분과 재사용이 가능할 만큼의 성능회복을 위한 복구비를 포함하는 것이 일반적이다. 건축물의 현존가치는 경과연수와 성능의 관계로부터 정의될 수 있다. 그런데 만일 지진피해를 입은 상태에서 건축물의 성능상태는 현지조사를 통해 쉽게 파악되겠지만, 지진으로 인하여 건축성능이 얼마큼 손상되었는지를 명확히 파악하는 것은 건축물의 성능상태를 사전에 알고 있지 않고서는 현실적으로 쉽지 않은 일이다. 그런데 통계에 따르면, 국내 건축물 동수 현황은 718만여 동이고, 이 중에서 각종의 법 규정에 따라 건축물의 상태나 안전성에 대하여 관리되는 건축물은 145천여 동으로 전체의 약 2%에 불과하고, 나머지 약 98%에 달하는 건축물에 대한 성능상태는 전혀 알 수 없다. 그래서 지진으로 인한 건축물의 경제적 피해를 정상적으로 예측하는 데는 한계가 있다. 이번 연구에서는 대다수의 건축물에 대해서는 현행법 규정에 따라 시행되는 “시설물 안전점검 및 정밀안전진단 지침과 같은 세부지침”에서 정한 정성적인 평가방법인 안전등급 판정을 준용해 성능을 정량적으로 평가하고, 모든 건축물에 대해 현장조사를 통하여 성능을 평가할 수 없음으로 경과연수에 따라 그 성능이 자연적인 감소되는 경향에 대하여 건축물의 성능곡선 모델을 통해 일반화하여 이들의 결과로부터 건축물의 현존가치 곡선 모델을 도출하고자 한다. 따라서 이번 연구에서는 경과연수에 따른 건축물의 성능지표와 현존가치 곡선 모델을 제안함으로써 ‘지진으로 인한 건축물의 피해예측 모델 개발’에 기여하는데 그 목적이 있다.
        339.
        2012.02 서비스 종료(열람 제한)
        건축물의 지진피해를 저감시키기 위해 국내에서도 다양한 실험과 연구가 이루어지고 있는데 그 중 건축물의 내진성능 진단방법 중의 하나로 전문가진단법과 같이 정량적인 내진평가를 얻기보다는 비전문가에게 사용 건축물의 구조적 이해를 돕기 위한 방법으로 일반인이나 건축물 관리자, 또는 비전문가가 사용할 수 있는 기초자진단법이 미국, 일본 등에서 많이 사용되고 있다. 본 연구는 국내 건축물 가운데 전통 기법으로 축조된 목조 건축물에 적용할 수 있는 내진성능 평가법을 개발하기 위하여 우선 해외 목조 건축물의 매뉴얼 및 진단지침 등을 조사·분석하였다. 국내·외 9개 기초자진단법의 비교분석을 통해 내진성능 평가를 위한 일반적・구조적 평가항목을 도출하였고 소유자나 일반인, 관리자가 목조 건축물의 내진성능에 대해 이해하기 쉽도록 사진과 그림이 첨가되고 항목수가 10개, 20개 항목으로 된 2가지 종류의 기초자진단법 매뉴얼을 제시하였다. 또한, 목조 건축물의 내진성능 기초진단법 적용성 분석을 위하여 실제 사용자들에 대한 설문조사 결과, 전체 응답자의 80%가 내진성능에 대한 정보 습득 경험이 없고 본 매뉴얼 정보에 대한 유용성과 활용성에 대하여 대체로 만족하다는 결과를 얻었다.
        340.
        2012.02 서비스 종료(열람 제한)
        지진은 바람 등을 포함한 다른 종류의 자연재해와 달리 현행 설계기준에 부합하도록 설계된 건축물이라고 하더라도 구조적/비구조적 손상을 발생시킬 수 있는 거의 유일한 자연재해이다. 이러한 건축물에 발생하는 손상은 경제적 피해를 발생시키며, 선진국으로 갈수록 지진발생 시 예상 경제적 피해는 기하급수적으로 증가하게 된다. 본 연구에서는 지진으로 인한 일정 지역에 위치한 건축물 손상이 야기시키는 경제적 손실을 산정하기 위한 방법론을 제시하고자 한다. 이를 위하여 우선 기존에 제시된 다양한 건축물의 경제적 손실평가 방법과 소방방재청에서 운용하고 있는 지진재해대응시스템의 내용에 대해서 간략하게 소개한 후, 현 지진재해대응시스템에서 사용하고 있는 다양한 기법을 최대한 활용하여 지진으로 인한 건축물의 구조적 손상에 의한 손실을 계산하고, 이를 해당 지역에 지역손실평가로 확장하는 일련의 방법론을 제시하고자 한다. 본 논문에서 소개하는 방법론은 상당부분 현재 미국에서 지진재해대응시스템으로 사용하고 있는 HAZUS 시스템의 일부를 국산화시킨 국내 소방방재청의 지진재해대응시스템에 개별 건축물의 지진으로 인한 손실평가 기법을 추가한 것이므로 현재의 지진재해대응시스템에 적용시켜 통합적으로 운용하기 편리할 것으로 판단된다.