검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,136

        561.
        2019.04 서비스 종료(열람 제한)
        In this study, the torsional strength of reinforced concrete hollow beams is predicted by nonlinear finite element analysis. A nonlinear finite element analysis program, ATENA, was used for the analysis. A total of six reinforced concrete beams were used and the analysis was performed under the same conditions as the actual test.
        562.
        2019.04 서비스 종료(열람 제한)
        The flexural strength of lightweight aggregate concrete (LWAC) T-beams reinforced with the minimum amount of longitudinal reinforcement could be conservatively predicted by the conventional procedure using the equivalent stress block specified in concrete code provision.
        563.
        2019.03 KCI 등재 서비스 종료(열람 제한)
        철근의 대체보강재로서 섬유보강근에 대한 적용연구가 증가하고 있으며, 단기거동에 대한 많은 연구가 진행되어 왔다. 본 연구에서는 동결융해와 알칼리 환경하에서의 바살트와 유리섬유보강근의 미세구조와 인장거동 변화를 실험적으로 평가하였다. 100회까지의 동결융해에서 5% 내외의 강도와 탄성계수 저하가 발생하였다. 20일까지의 초기 미세구조변화의 경우 알칼리용액의 온도가 낮은 경우에는 손상이 거의 발생하지 않았으나, 60℃에서는 20일 경과시에도 수지 용해와 섬유 손상이 관찰되었으며, 수지계면의 섬유분리가 발견되었다. 알칼리 환경에서는 20℃환경에서 100일까지는 10% 내외의 강도저하 현상이 발생하였으며, 500일 노출시 최대50%의 강도 저하가 발생하는 것으로 관찰되었다. 40℃와 60℃ 환경에서는 50일과 100일에서 급격한 강도저하가 관찰되었으며, 바살트섬유보강근의 경우에는 알칼리에서 섬유부풀음에 의한 손상으로 강도저하가 더 크게 나타났다. 따라서 블레이디드된 섬유보강근의 장기성능을 향상시키기 위해서는 내알칼리성 확보를 위한 표면처리가 필요한 것으로 분석되었다.
        564.
        2019.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 탄소섬유시트, 아라미드섬유시트, 그리고 유리섬유시트를 혼합한 하이브리드 FRP 플레이트를 제작하였으며, 제작한 보강 플레이트를 보강한 후, 최대한의 휨 보강 효과가 발생되도록 다시 보강 플레이를 긴장시켜 RC보의 휨 보강 효과를 파악하고자 하였다. 또한, 긴장시키는 보강방법을 제시하는 동시에 무보강 실험체에 비해 보강효과가 어느 정도 되는지 실험적으로 규명하기 위해 실험적 연구를 진행하였다. 연구를 위해 총 8개의 RC 보 부재를 동일하게 제작하여 1 개의 실험체(N 실험체)를 제외한 7 개의 실험체는 보강재 종류, 단부 정착 앵커 개수, 보강재 두께 등을 주요 변수로 하여 실험을 실시하였다. 실험결과, 휨 거동을 보이는 실험체에 긴장을 가한 FRP 플레이트로 보강하면, 보강하지 않은 실험체에 비해 우수한 휨거동(초기강도, 항복시 강도 및 강성, 최대강도 등)보여 주었으며, 단부정착 앵커의 개수가 많고, 보강재의 두께(보강량)가 클수록 보강효과가 우수한 것으로 나타났으며, 긴장시킨 보강재는 단일 FRP 플레이트에 비해, 하이브리드 FRP 플레이트를 적용했을 때 보강효과가 더 우수하게 나타났다.
        565.
        2019.01 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 강 - PC 복합모듈 골조를 구성하는 프레스 성형된 비대칭 기둥과 보 접합부의 구조적 성능을 평가하는 것이다. 모듈러 골조를 구성하는 대부분의 접합부는 폐쇄형의 사각형 강재 기둥 단면을 주로 사용한다. 폐쇄형의 기둥 단면을 사용한 기둥-보 접합부는 시공성을 감소시키고 내화성을 확보하는데 어려움이 있다. 이러한 단점을 극복하기 위하여 강판을 프레스로 성형하여 비대칭 개방형 단면 내에 콘크리트를 충진하는 것이다. 프레스 성형된 비대칭 기둥-보 접합부의 구조적 성능을 조사하기 위해 총 4개의 실험체를 제작하였다. 실험결과, 비대칭 기둥의 구조적 성능과 거동이 비대칭 기둥 단면이 합성되는지 또는 기둥의 폭-두께 비율에 따라 달라지는지를 보여주었다. 프레스 성형된 비대칭 기둥-보 접합부의 구조적 성능은 실험결과와 이론식을 비교하여 평가하였다.
        566.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        순환골재를 사용한 철근콘크리트 부재에서 휨강도에 비하여 전단성능 저하가 문제점으로 제기되고 있다. 이를 해결하기 위한 방법으로 강섬유를 콘크리트 보강재로 사용할 수 있다. 본 연구에서는 순환골재를 사용한 SFRC 보의 전단실험을 통하여 강도 및 변형 특성을 파악하고자 하였다. 주요 실험변수는 강섬유 혼입률(0, 0.5%, 1%), 순환골재 치환율(0%, 100%), 전단경간비(a/d = 1, 2) 등이다. 실험결과 실험에 의한 전단강도는 강섬유의 혼입률이 증가할수록 전단경간비가 작아질수록 증가하였다. 강섬유 1% 혼입한 순환골재의 경우 일반 골재에 비해 최대전단내력이 1.77~6.25% 증가한 반면에 강섬유 0∼0.5% 혼입한 실험체에서는 일반골재에 비해 순환골재가 24.2%∼49.2%의 전단강도가 저하되었다. 이를 볼 때 1% 강섬유 보강에 의하여 순환골재 사용에 따른 강도 저하를 방지하는데 크게 기여하는 것을 알 수 있다.
        567.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        기존 콘크리트 구조물의 노후화 또는 지진과 같은 외부 하중에 의하여 구조물의 구조 성능이 저하되기 때문에, 기존 건물의 보수 및 보강 연구는 중요하다. 외부부착 탄소섬유 보강 공법과 같은 효율적인 보수 공법을 사용하면 경제적으로 콘크리트 구조물의 구조 성능을 높일 수 있다. 따라서 외부부착 탄소섬유를 사용한 콘크리트 부재의 실험 연구는 많이 진행되었다. 특히, 콘크리트 보를 사용한 전단 보강에 관한 연구는 탄소섬유의 양, 부착 각도, 스트립의 폭, 그리고 재료간의 상호작용에 관한 것이었다. 하지만 선행된 연구에 비하여 탄소섬유의 이 방향 레이아웃에 관한 다양한 변수 연구는 부족한 상황이다. 따라서 이 연구에서는 이 방향 레이아웃 외부부착 탄소섬유 공법을 사용하여 콘크리트 보의 전단보강 효과를 검증하였다. 이 방향 레이아웃의 보강 효과는 스터럽과의 전단 기여도, 실험체의 전단 거동과 보강 시점에 따른 최대 내력의 비교를 통하여 이루어졌다.
        568.
        2018.10 서비스 종료(열람 제한)
        This study evaluated the fiber orientation and distribution fiber in the beam members of cementitious materials using conventional and tapered nozzles. For this purpose, the specimens with 10cm × 10cm × 30cm were vertically cast to evaluate the fiber orientation and distribution coefficients on the cutting plane. Compared to the conventional nozzle, the tapered nozzle showed an improvement in the fiber orientation and distribution in the beam member.
        569.
        2018.10 서비스 종료(열람 제한)
        The flexural behavior of reinforced concrete (RC) beams strengthened with an iron based-shape memory alloys strip(Fe-SMAs) by a near-surface mounted (NSM) method was evaluated. The pre-strained values of 0% and 4% and introduced prestressing force by an activation of a shape memory effect of the Fe-SMA strengthening material were considered as experimental variables. The experimental results show a large increase in initial stiffness of beams reinforced with 4% pre-strain. On the contrary, The effect of prestressing seems to be insignificant on the yielding and ultimate loads of tensile bars.
        570.
        2018.10 서비스 종료(열람 제한)
        This In paper In this research a experimental and analytical study were performed to investigate strengthening efficiency of a hybrid material beam developed with the goal of simultaneously increasing the flexural stiffness and strength of aging RC structures. A composite beam consisted of two materials ; aluminum, GFRP. The experimental investigation consisted of testing 3 simply supported full-scale concrete beams. As test variables, the cross-sectional type of hybrid material beam(BE-2, SH-2). Test results show that the stiffness and load capacity of all specimens strengthened with hybrid material beam increased compared with unstrengthened specimens. A hybrid material beam of BE-2 was more efficient for stiffness increase than a un non-strengthened beam of U-B. A damage by power pin install reduce flexural load-carry capacity to 7∼10%. Specimens with high reinforcement raito had larg load-carry capacity than specimens with low reinforcement ratio and had small load-carry increase ratio compare with theoretical load-carry capacity of non-strengthen.
        571.
        2018.10 서비스 종료(열람 제한)
        An experimental study was conducted to examine for the structural behavior of coupled steel plate shear wall (Coupled SPSW) system what is formed by connection the two steel plate shear walls (SPSW) with a coupling beam. The variable of this study was the length of coupling beam. The testing results were showed that the strength and stiffness of specimen with shorter coupling beam were improved than those of other specimen. However there is no difference of the yielding mechanism.
        572.
        2018.10 서비스 종료(열람 제한)
        This study compared the experimental values obtained from existing papers and the analytical values obtained using nonlinear finite element analysis programs. The results show a similar aspect, with a yield load of 74.5 kN in the experiment and a yield load of 69.3kN in the analysis result showing a difference of about 6%.
        573.
        2018.08 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 실내실험을 통하여 개량형 공압식 가동보를 대상으로 수로경사 변화를 고려한 유사의 수리학적 발달 과정을 분석하였다. 분석결과 보에 의하여 형성된 델타는 시간이 증가함에 따라 하류로 이동하며, 델타높이(hd)는 증가하였다. 또한 보에 도달 할수록 흐름이 약해지면서 델타의 이동속도(SD)는 감소하였다. 무차원 델타 위치(xD/x)가 증가할수록 무차원 델타의 유효높이(hd/hw)와 무차원 저수지 용량(VxD/Vx)이 증가였다. 따라서 동일한 조건에서 수로경사(i)가 완만할수록 델타의 퇴적량(QS)이 감소하게 되며, 델타의 체적(VxD) 발달에 큰 영향을 미치는 것으로 나타났다. 통수 초기 델타의 전면경사가 완만하며, 델타가 하류로 이동할수록 델타의 전면경사는 증가하였다. 또한 수로경사(i)가 완만할수록 델타의 전면부 길이 비(hd/△S)는 1에 가까워지고, 무차원 델타의 높이(hd/h)와 무차원 델타의 이동속도(SD/V0)가 감소하였다. 델타의 높이(hd)가 증가할수록 수심(h)은 감소하였으며, 보에 접근하는 유속(V0)과 델타의 이동속도(SD)도 감소하였다.
        574.
        2018.08 KCI 등재 서비스 종료(열람 제한)
        수자원의 추가 확보와 홍수에 대한 선제적 대응을 목적으로 국내 4대강 주요 지점에 다기능보(multi-function weir)를 설치하였다. 다기능보는 흐름 통제 단면으로서 정밀한 유량 산정이 가능한 수리구조물로 하천의 일반적인 수위-유량 관계식보다 정밀하게 산정할 수 있으며, 향후 각 유역의 국가 표준 유량 기준점으로 활용할 수 있는 방안을 강구하는 것이 바람직하다. 이에 본 연구에서는 영산강의 승촌보를 대상으로 현재 취득되는 운영 자료를 분석하여 개선사항을 제시하고, 이를 보완하기 위하여 간접유량추정 방법인 경사-면적법(slope-area method)을 응용하여 정밀한 유량 산정이 가능할 수 있는 방법을 제안하고자 한다. 분석 결과, 현재 상태는 이론적인 유량계수 범위 초과와 급격한 변동, 상 ․ 하류부의 수위차를 연동하지 못하는 등 이에 대한 보완이 필요하였다. 응용한 경사-면적법은 앞서 제시한 한계점을 보완하고, 자연 하도의 검증된 수리학적 이론에 의해 수면경사와 마찰손실을 반복 계산을 통해 오차를 줄여나가는 상호 보완적인 방법으로 물리적으로 타당하여 적용가능성을 확인하였다. 향후, 다기능보의 최적 운영을 위하여 이를 적용한다면, 실제 운영에 도움이 될 것으로 기대된다.
        575.
        2018.08 KCI 등재 서비스 종료(열람 제한)
        국가직무능력표준 NCS(National Competency Standard)은 고등직업교육기관인 전문대학을 기반으로 하여 시행되어 지고 있다. 전문대학은 학생들이 졸업과 동시에 근무현장에서 최대한의 역량을 수행할 수 있도록 지식. 기술. 태도라는 3가지의 영역을 편성하여 집중적인 교육을 하고 있다. 전문대학 중에서 보건계열은 의료기사 영역을 포함한 다양한 의료 인력을 양성하고 있다. 특별하게도 의료기사 및 의료 분야들은 반드시 면허를 필수적으로 취득해야 의료분야에서 근무를 할 수 있다. 따라서 방사선사면허 국가시험의 합격은 취업의 전제조건이다. 이번연구에서는 방사선사면허 국가시험을 앞둔 D 전문대학 방사선과 3학년 학생들 (229명)의 보건법규 점수를 주차별로 분석하였다. 이러한 주차별 점수획득은 학생들의 개개인별 학습 성취 패턴을 분석할 수 있다. 더 나아가 이러한 결과는 학생들 개인별 방사선사면허 국가시험 합격의 가·부를 예측할 수 있게 해준다.
        576.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        본 연구는 순환골재를 사용한 콘크리트의 활용증대 방안으로 철근콘크리트 구조물의 노후화와 내구성 저하 시 보수․보강으로 사용되는 FRP (AFRP, CFRP) 판으로 보강된 순환골재 고강도콘크리트(40MPa, 60MPa) 보를 제작하여 순환골재 철근콘크리트 보의 휨 보강에 대한 적용성을 평가하고자 한다 기존의 표면매입보강에 따른 에폭시와 FRP 판의 부착력을 고려하지 않기 위해 콘크리트 타설 전 FRP 보강판을 거푸집에 미리 설치하였으며, 순환골재 치환율(30%), 콘크리트 강도(40MPa, 60MPa), 이형철근(D10, D13), FRP 판의 종류(AFRP 판, CFRP 판)를 변수로 12개 실험체를 제작하여, FRP 판과 순환골재 치환율에 따른 휨 성능을 분석하였다. 그 결과 FRP 판으로 보강한 실험체는 무보강 실험체에 비해 최대 17% 증가하는 경향을 나타내었으며 AFRP 판에 비해 CFRP 판의 보강 성능이 우수한 것으로 나타났다. 또한 순환골재 치환율에 따른 보강 성능의 차이는 없는 것으로 나타났다. 실험에 의해 측정된 균열모멘트는 파괴계수를 이용한 결과 기준식과 비슷한 값을 나타났으며 휨 모멘트는 FRP 판을 보강한 일부 시험체가 KCI 2012와 ACI 440-2R에서 제시한 기준을 만족하지 못하는 것으로 나타났다.
        577.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        기존 구조물의 노후화로 인하여 보수 및 보강에 관한 연구는 활발히 이루어지고 있다. 탄소섬유를 사용한 외부 부착공법은 경제적이고 짧은 시간에 보강 작업이 이루어질 수 있기 때문에 널리 사용되고 있다. 일반적으로 탄소섬유를 사용한 전단 보강에는 일 방향 레이아웃이 많이 사용되고 있으며, 재료의 양, 섬유의 각도 그리고 간격 등에 관한 실험 연구가 많이 진행되었다. 하지만 예비 실험 결과를 통하여 이 방향 전단보강 레이아웃은 일 방향 전단보강보다 좀 더 효율적으로 부재를 구속하는 것을 확인하였다. 따라서, 유사한 재료의 양을 사용하여 일 방향과 이 방향 전단 보강 작업이 이루어진 후 실험을 통하여 두 보강작업의 효과가 검증되었다. 탄소섬유 보강 작업을 할 때는 탄소섬유의 부착 파괴를 방지하기 위하여 탄소섬유 앵커가 설치되었다. 탄소섬유 앵커와 탄소섬유 레이아웃의 전단보강 효과는 실험 경간에 발생한 주인장 변형률의 분포를 통하여 검증되었다.
        578.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 철근콘크리트 휨 부재에 탄소섬유시트, 유리섬유시트, PET(polyethylene terephthalate) 섬유 등을 이용하여 보강 했을 때, 보강재 종류, 보강재 물성, 보강량 등에 따른 보강효과를 파악하는 것이다. 변수별 보강효과를 파악하기 위해 가상의 휨부재를 기준실 험체로 선정하여, 기준실험체에 대해 항복단면과 극한단면일 때의 모멘트-곡률 관계를 파악하였다. 보강하지 않은 기준실험체에 보강재 종류, 보강재 물성, 보강량 등 다양한 변수를 적용하여 총 11개의 실험체의 모멘트-곡률 곡선을 비교하였다. 분석 결과, 보강하지 않은 실험체에 비해 보강한 실험체의 휨강도는 높게 나타났다. 그러나 연성에 대해서는 보강하지 않은 기준실험체가 가장 우수한 것으로 나타났다. 변수별 휨 보강 효과는 보강량이 많고, 파괴시 재료강도가 높을수록 우수하게 나타났으며, 연성효과는 보강재의 파괴시 변형률이 높을수록 우수한 것으로 나타났다. 손상 전과 손상 후의 보강효과에 대해서는 휨보강 효과와 연성효과 모두 10% 이내로 미미하게 나타나 손상상태에 있더라도 온전한 상태로 해석해도 큰 차이가 없을 것으로 판단된다.
        579.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        이 연구는 유공보강근의 형상에 따른 철근콘크리트 유공 보의 전단저항성능을 평가하기 위하여 4체의 실험체를 제작하여 전단실험을 수행하였다. 실험의 주요변수는 유공의 유무, 유공보강 유무, 유공 보강근의 형상으로 하였으며, 제안 유공 보강근은 시공성을 고려하여 사각형과 마름모형이 혼합된 나선형 형태이다. 실험결과, 이 연구에서 제안된 유공보강근은 유공 주변의 균열을 효과적으로 제어하여 실험체의 전단력 향상에 효과적임을 확인하였다. 또한 현행설계기준은 유공 보강근을 배근한 실험체의 실험결과를 과소평가하는 것으로 나타났다.
        580.
        2018.05 KCI 등재 서비스 종료(열람 제한)
        표면매립공법으로 매립한 철계-형상기억합금으로 보강한 보의 휨 거동을 장기 하중 재하실험을 통해 평가하였다. 철계-형상기억 합금 길이대비 2%와 4%의 사전변형 및 형상기억효과 활성화에 의한 프리스트레스 하중 도입을 실험변수로 설정하였다. 1 tonf의 콘크리트 추를 보 중앙에 거치한 후 6개월간의 보 중앙부의 장기 처짐을 측정하였다. 실험결과, 철계-형상기억합금으로 보강한 보의 휨 강성이 증대되었으며, 사전변형이 증가할수록 보강재의 강성감소로 인한 처짐이 증가하는 것으로 나타났다. 프리스트레스 하중 도입에 따른 처짐을 비교했을 때, 프리스트레스 하중을 도입하지 않은 실험체에 비해, 프리스트레스 하중을 도입한 실험체는 약 30%의 처짐 감소 효과를 보이는 것으로 나타났다.