검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,425

        1361.
        2006.08 KCI 등재 서비스 종료(열람 제한)
        Since low-floor apartments are vertically closer to parking lots and roadways, it is hypothesized that residents in low-floor apartments may be exposed to elevated ambient levels of motor vehicle emissions compared to residents in high-floor apartments. The present study examined this hypothesis by measuring two motor vehicle source-related pollutants(CO and PM10) in ambient air of high-rise apartment buildings within the boundary of industrial complexes according to atmospheric stability. The ambient air concentrations of CO and PM10 were higher for low-floor apartments than for high-floor apartments, regardless of atmospheric stability. The median concentration ratio of the low-floor air to high-floor air ranged from 1.3 to 2.0, depending upon atmospheric stabilities, seasons and compounds. Moreover, the CO and PM10 concentrations were significantly higher in the winter and in the summer, regardless of the floor height. Atmospheric stability also was suggested to be important for the residents' exposure of high-rise apartment buildings to both CO and PM10. The median ratios of surface inversion air to non-surface inversion air ranged from 1.2 to 1.7 and from 1.0 to 1.6 for PM10 and CO, respectively, depending upon seasons. Conclusively, these parameters(apartment floor height, season, and atmospheric stability) should be considered when evaluating the exposure of residents, living in high-rise apartment buildings, to CO and PM10. Meanwhile, the median PM10 outdoor concentrations were close to or higher than the Korean annual standards for PM10, and the maximum PM10 concentrations substantially exceeded the Korean PM10 standard, thus suggesting the need for a management strategy for ambient PM10. Neither the median nor the maximum outdoor CO concentrations, however, were higher than the Korean CO standard.
        1366.
        2005.06 KCI 등재 서비스 종료(열람 제한)
        In the absence of exogeneous nitrogen supply, evaluation of a symbiosis effectiveness of Bradyrhizobium japonicum USDA 110 in a supernodulating soybean mutant, SS2-2, its wild type, Sinpaldalkong 2, and control genotype, Jangyeobkong, was conducted in this study. Nodules in SS2-2 were initially white and similar to its wild type, Sinpaldalkong 2. At the late stage, the wild type nodules became dark pinkish by maturation, by contrast, mature nodules in SS2-2 remained light green to pinkish, indicating a lack of leghemoglobin. Tap root length was short in nodulated symbiotic SS2-2 than that of its wild type and the control genotype. Nodulated root length and nodule density on root length were significantly increased by B. japonicum inoculation, but no significant increase was observed on root length and percentage of nodulation to total root length. Regardless of Bradyrhizobium inoculation, SS2-2 showed higher nodule dry weight and higher acetylene reduction activity (ARA) when compared with its wild type and the control genotype. Inoculation of B. japonicum leaded the increase of ARA in 47 days after planting (DAP), in part because of nodule development. Supernodulating mutant, SS2-2, less responded to B. japonicum induction in terms of nitrogen fixation and nodulation characteristics than its wild type. Thus, interaction of supernodulating soybean mutant with Bradyrhizobium had less symbiotically associated response than normal nodulating soybean.
        1367.
        2005.05 KCI 등재 서비스 종료(열람 제한)
        This study is designed to investigate the characteristics of PM10 concentration and the chemical composition of heavy metallic components in the PM10 sampled in western Busan from March to May, 2003. PM10 measurement was done during springtime of 2003, totaling 29 days: 9 days in March, 10 days in April and 10 days in May. With a sampling time of 24 hours, it started 9:00 AM on that day and ended 9:00 AM the next day. The mean contribution ratio of soil during springtime was 10.3 %. Al had a significant correlation with Ca, Fe, Mg and Si and little correlation with Na, Ni and Zn.
        1369.
        2004.12 KCI 등재 서비스 종료(열람 제한)
        난소가 제거된 생쥐를 이용하여 자궁조직에서의 ADAM-8, 9, 10, 12, 15, 17, 그리고 ADAMTS-1의 유전자의 발현이 생식호르몬에 의하여 조절되는 지를 알아보았다. 암컷 생쥐의 난소를 제거하고, 2주후에 sesame oil, 17 -estradiol (), progesterone ( 혹은 이 둘 혼합액 ()을 피하 주사하였다. RT-PCR 방법을 이용하여 유전자 전사체의 발현을 조사한 결과 ADAM-8, 12, 그리고 17은 oil을 주
        1373.
        2004.09 KCI 등재 서비스 종료(열람 제한)
        Sinorhizobium sp. strain MUS10 forms nitrogen-fixing stem nodules on Sesbania rostrata, a tropical green manure crop. In this study, the ultrastructural events associated with the formation of stem nodules were investigated. Sinorhizobium sp. strain MUS10 entered the host tissue through cracks created by the emerging adventitious root primordia and multiplied within the intercellular spaces. During early phases of infection, host cells adjacent to invading bacteria revealed cellular damage that is typical of hypersensitive reactions, while the cells at the inner cortex exhibited meristematic activity. Infection threads were numerous in S-day-old nodules and often were associated with the host cell wall. In several cases, more than one infection thread was found in individual cells. The junction at which the host cell walls converged was often enlarged due to fusion of intracellular branches of infection threads resulting in large infection pockets. The infection threads were made up of a homogeneous, amorphous matrix that enclosed the bacteria. Several finger-like projections were seen radiating from these enlarged infection threads and were delineated from the host cytoplasm by the plasma membrane. As in Azorhizobium caulinodans induced root nodules, the release of Sinorhizobia from the infection threads into the plant cells appears to be mediated by 'infection droplets'. A 15-day­old Sesbania stem nodule revealed typical ultrastructure features of a determinate nodule, containing several bacterioids within symbiosomes.
        1376.
        2004.01 KCI 등재 서비스 종료(열람 제한)
        체계적으로 분석된 대구지역의 PM10 오염도의 시간적 및 공간적 특성과 대조지역에서 측정된 PM10 오염도에 근거하여 대구지역의 PM10 오염에 대한 저감 방안이 다음과 같이 제시된다. 대구시의 지역특성에 따른 PM10 관리의 관점에서 볼 때 대구지역의 PM10 관리는 다른 지역보다는 도로변 또는 도로변 인근지역, 그리고 공업지역에서 우선적으로 이루어져야 하고 지역적으로 PM10 관리 전략을 달리하여야 함을 제시하고 있다. 남산동, 삼덕동 및 대명동을 포함하여 도로변 또는 도로변 인근의 주택에 거주하는 주민의 PM10으로부터 건강 위해성을 줄이기 위해서는 자동차 교통 관리가 가장 우선적으로 수행되어야 한다. 한편, 노원동과 중리동을 포함한 공업지역 또는 인근에 거주하는 주민의 PM10으로부터 건강 위해성을 줄이기 위해서는 자동차 교통 관리 보다는 공단 배출 PM10 관리가 가장 우선적으로 수행되어야 한다. 나아가, 본 연구결과에 기초할 때, 비록 만성영향과 밀접한 관련이 있는 평균농도는 모든 지역에서 PM10 대기환경 기준치 이하로 나타났지만, 급성영향과 밀접한 관련이 있는 최대 농도와 결코 낮지 않은 PM10 대기환경 기준치를 초과하는 빈도수를 고려할 때, 대구지역의 PM10 관리는 지속적으로 수행되어야 함이 강조된다. 대구지역의 시간대 별 PM10 관리 관점에서 볼 때, 대구의 일반 주거지역의 PM10 관리는 오전 10시에서 오후 1 3시에 집중되어야 효율적인 PM10 관리가 될 수 있음을 의미한다. 공업지역인 중리동과 노원동의 경우, 다소 이른 오전 7시부터 오후 1 2시 사이에 PM10 관리가 집중되어야 효율적인 PM10 관리가 될 수 있을 것이다. 반면에 상업/주거 지역인 삼덕동과 대명동 그리고 도로변 지역인 남산동의 경우, 특정 시간대가 아닌 거의 전 시간대에 걸쳐 PM10 관리해야 하고 특히 자동차 배출 PM10 관리대책 수립이 시급하다. 대구지역의 요일 별 PM10 관리 관점에서 볼 때, 모든 지역에 대하여 일요일과 월요일의 PM10 농도가 낮게 나타났으므로 화요일에서 토요일까지 집중되는 것이 PM10관리가 효율적으로 수행될 수 있음을 의미한다. 대구지역의 월 별 PM10 관리 관점에서 볼 때, 모든 지역에서 하절기인 7월, 8월 및 9월에 낮은 농도를 나타내었고, 동절기인 11월 2월 보다는 오히려 이른 봄인 3월에 최대 농도를 나타내고 있으므로 모든 지역에서 3월에는 특별한 PM10 관리가 이루어져야 하고, 특히 근본적인 문제점인 중국의 황사현상을 저감하기 위한 중국과의 외교적인 노력이 요구된다. 대구지역의 계절 별 PM10 관리 관점에서 볼 때, 계절적으로는 모든 지역에서 봄철에 가장 PM10 농도, 그 다음이 겨울, 가을 그리고 여름의 순으로 나타났다. 봄철의 가장 높은 PM10 농도와 여름철의 가장 낮은 PM10 농도는 앞의 월별 PM10 농도 변화에서도 설명된 바와 같이 각각 황사와 장마의 영향 때문인 것으로 사료된다. 여름과 가을 보다 높은 PM10 농도를 나타내는 겨울철의 경우, 난방 연료 사용의 증가로 인한 영향을 받는 것으로 사료되므로 청정연료 사용의 확대가 권장된다. 대부분의 경우, 대조지역에서 측정된 PM10 농도가 대구의 여섯 개 대기오염측정 지점에서 측정된 PM10 농도 보다 낮게 나타났고, 일부는 일반주거지역인 만촌동과 유사하게 나타났다. 따라서, 대구의 PM10 측정망 중에서 만촌동이 주위 PM10 오염원의 영향을 가장 적게 받는 주거지역임을 함께 고려할 때 대구시의 PM10 관리목표는 만촌동의 PM10 수준으로 유지함이 바람직한 것으로 제안된다.
        1377.
        2003.12 KCI 등재 서비스 종료(열람 제한)
        최근 사람의 난포액에 존재하는 gelatinase 중 EDTA처리에 의해 활성이 크게 증가하는 GA110을 발견하였으며, 본 연구에서는 이러한 GA110이 만들어지는 기작을 알아보고자 하였다. 먼저, protein disulfide isomerase(PDI)가 관여하는지 알아보기 위해 PDI 저해제를 처리하여 GA110의 활성을 조사하였다. 난포액에 EDTA를 처리하기 전에 저해제를 첨가하여 반응시키면 저해제 의 농도가 증가할수록 GA110의 활성 이
        1379.
        2003.10 KCI 등재 서비스 종료(열람 제한)
        Hourly data of PM10 concentration collected from nine automatic air quality monitoring stations in Busan from 1999 to 2002 were analyzed to evaluate the spatio-temporal variation and meteorological characteristics of PM10 episodes in Busan metropolitan area. Mean concentrations ranged from 47㎍/m3 to 77㎍/m3. For most stations, mean seasonal hourly concentrations are lowest in summer and highest in spring. PM10 episode above daily mean standard(150㎍/m3) exhibited a maximum frequency at Gamjeondong and a minimum at Dongsamdong, and a maximum in March and a minimum in July and August. The diurnal variation of PM10 episode days is strongly influenced by traffic loads and meteorological conditions.