검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 24

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently a biosafety level-3(BL-3) mobile laboratory has been set up for the virus scanning and vaccine development because of the COVID-19 pandemic. The study on air flow inlet and outlet location and its flow direction with ventilation in the mobile laboratory needs to prevent spread of COVID-19 virus because the COVID-19 virus is primarily transmitted to people through respiratory droplets and aerosol coming out as their coughing. This study is conducted on the air flow pattern optimization in BL-3 mobile laboratory with various design specifications of position of air supply & exhaust port and particle source. Air flow patterns of ceiling supply-exhaust and ceiling supply-bottom side exhaust with particle source were determined to compare the impact of the infection prevention. CFD simulation was used to analyze for two air flow patterns and particle source position. Numerical results showed that air flow pattern of air conditioning system with ceiling supply-exhaust in a row is more effective than that of ceiling supply-bottom side exhaust air flow pattern in terms of infection prevention in biosafety mobile laboratory.
        4,000원
        5.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 우리나라 기업들의 교육훈련감소추세에 대한 문제제기와 함께 그 원인을 파악하고자 하였다. 기존연구에서도 교육훈련의 긍정적 효과에 대한 연구를 제시하고 있으나 본 연구에서는 성과측정에 대한 변수를 보다 명확하게 추출하여 우리나라 기업의 교육훈련이 기업의 성과에 어떤 영향을 주는지에 대해 가설을 설정하고 회귀분석의 방식을 적용하여 검증하였다. 교육훈련시간과 교육훈련비용은 기업의 인적자원개발의 성과지표에 긍정적인 영향을 미치는 것으로 실증되었고 교육훈련비보다는 교육훈련시간이 각종 성과지표에 더욱 탄력적으로 영향을 주는 것으로 나타나 교육훈련시간의 관리가 중요한 것으로 분석되었다. 아울러 국내외적으로 경쟁의 가중되는 기업환경 속에서 기업 관리자들은 인적자원개발활동 중 교육훈련의 중요성과 그 효과에 대해서 명확하게 인식하고 교육훈련을 통한 인적자원개발에 관심과 노력을 많이 집중함으로써 기업이 경쟁적 우위를 확보할 필요성이 크다는 결론에 이르게 되었다.
        5,400원
        6.
        2015.03 구독 인증기관 무료, 개인회원 유료
        생물학적 위험등급 3등급 BL3용 공조기의 급배기는 밀폐 연구시설 사이의 교차오염을 막기 위하여 관계 규정에 의거 전외기 방식을 택하고 있다. 이와 같은 전외기 방식의 공조기는 에너지 소비가 많으며 게다가 BL3의 경우 하루 24시간 운전으로 인하여 에너지 소비가 매우 많으며 또한 연구시설의 대형화로 인하여 에너지 소비는 더욱 증가하게 될 것이다. BL3용 공조기에서의 에너지 절약에 관한 연구로는 국외의 경우 전외기 방식에서 급기와 배기덕트 사이에 부동액 등을 사용한 핀-튜브 열교환기를 사용하여 배기로부터 열회수를 통한 에너지 절약에 관한 연구를, 국내의 경우 생물학적 안전성을 기반으로 하는 재순환에 의한 에너지 절약에 관한 연구를 시도하고 있다. 본 연구에서는 기존의 BL3용 공조기에서 주로 사용하는 핀-튜브 열교환기와 마이크로 채널 열교환기에 대한 특성을 비교, 연구하였고 마이크로 채널 제작을 위한 열교환기 설계 프로그램을 개발하였다.
        3,000원
        9.
        2013.08 구독 인증기관 무료, 개인회원 유료
        This paper presents that hybrid cooler of vapor compression type and natural refrigerant circulation type is energy saving cooler using R-410a for indoor mobile telecommunication station. Its performance and operation characterists are done experimently about receiver tank, piping and heat exchanger designs for natural circulation of refrigeration and use of R-410a for fixed height location difference of indoor and outdoor cooler.
        4,000원
        11.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This is the competitive structure of the wave power is studied thru patent information analysis with using of DWPI. The competitive structure is analyzed with worldwide patent pending(resistration) by year-on-year and patent pending(resistration) by nationality and IPC patent pending(resistration) current status by nationality and with technology development change of IPC patent pending(resistration) by nationality and the present condition of yesr-on-year patent pending(resistration) of main nations.
        4,000원
        12.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This analyzed the competitive structure of heat pump by nationality, by year-on-year and by technology on patent pending thru patent information analysis and applied KISTI holding DWPI for it. Heat pump technology is expected to position at development period or at start point reaching puberty just got out development period and to be consistently developed thru patent portfolio analysis.
        4,000원
        14.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The hybrid cooling system of vapor compression system and naturally circulating coolin system using R-410a for indoor mobil tele-communication center(IMTC) is developed and its performance is experimentally studied. Its results are summarized as follows. First, cooling capacity of naturally circulating cooling system is proportional to indoor and outdoor temperature difference and it has max. 4,550 kcal/h at indoor and outdoor air temperature difference 15℃. Second, heat exchangers of evaporator and condenser should be designed and constructed to be able to get maximum refrigerant capacity by naturally circulating force and to enhance heat transfer by refrigerant. Third, cooling capacity of hybrid cooling system has optimum operating point according to refrigerant charging capacity and refrigerant charging capacity of naturally circulating cooling system is 30~50% more than vapor compression refrigeration system.
        4,000원
        15.
        2008.03 KCI 등재 구독 인증기관·개인회원 무료
        1 2