        1.
        2011.11 구독 인증기관 무료, 개인회원 유료
        The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.
        4,000원
        2.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of the study was to improve of performance for Magnetic Resonance Imaging (MRI) examination in the department of radiology. It was performed DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, The fifth kinds of CTQ (critical to quality) by the kindness, the waiting time, the examination explanation, the waiting time and the waiting environment were selected by voice of customer. In the stage of measurement, the performed examinations and the reservation waiting time were measured each 1.77 and 1.69 sigma. In the stage of analysis, the potential key causes were determined the limited working hours and the difference of examination time of various entries. In the stage of improvement, MRI were performed with the operating system of 24 hours examination and the optimization of the difference of examination time by among of 30 minutes, 40 minutes, 50 minutes. Finally, the number of examinations and reserved waiting days were measured by each 3.17 and 1.71 sigma in the control stage.
        4,000원
        3.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ± 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ± 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).
        4,000원
        5.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.
        4,000원
        6.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of the study was to apply and to expand the six sigma to reduce waiting times for computed tomography (CT) examination which manipulated by the department of radiology. It was preceded by DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, it wereselected for total 5 critical to quality (CTQ), which were the kindness, the waiting time, the examination explanation, the waiting day and the waiting stand environment, that increased the reserved time of CT examination. In the stage of measurement, the number of examinations and of reservation waiting days performed and resulted in final CTQ(Y) which measured each 1.68 and 1.85 sigma. In the stage of analysis, the examination concentrated on morning time, non-scheduled examination of the day, the delayed time of booking, frequent telephone contacting and equipment malfunction were determined as variable key causes. In the stage of improvement, it were performed with expansion of the examination in the morning time, integration of laboratories that used to in each steps, developing the ability of simultaneous booking schedule for the multiple examinations, developing program of examination request, and the customer management team operations. For the control, the number of examinations and reserved waiting days were measured each 3.14 and 1.13 sigma.
        4,000원
        7.
        2010.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.
        4,000원
        8.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To investigate acute drug intoxication trends in the elderly visited Emergency Medical Centers, Data was collected from the records of poisoning patients visited Five different Hospitals from January 1. 2007 to December 31. 2007. The analysis was conducted by using 135 cases of 624 cases. When considering only the elderly and making comparisons between the urban areas and the rural areas the following data was produced. In regard to patients with acute drug intoxication, the main substance of choice was pesticides. Cases of acute drug intoxication are definitely higher for those categorized as the rural elderly (75.0%) when compared with those categorized as the urban elderly (44.1%). The male to female ratio, those living together as a family, past suicide attempts, mental state and sobriety condition when they came, monthly distribution etc. between the two groups did not demonstrate a difference between them. In regard to reasons given for acute drug intoxication, suicide was the highest at 60.7% of the cases. When comparing accidental reasons for poisoning, the urban elderly, at 34.2% of their cases, were higher than in the rural elderly, at 23.7%. After first aid was administered, the admission rate was higher for the rural elderly (47.4%) than for the urban elderly (33.9%). This shows that the rural elderly have a more severe acute drug intoxication poisoning problem than the urban elderly do.
        4,000원
        9.
        2009.11 구독 인증기관 무료, 개인회원 유료
        To investigate acute drug intoxication trends in the elderly visited Emergency Medical Centers, Data was collected from the records of poisoning patients visited Five different Hospitals from January 1. 2007 to December 31. 2007. The analysis was conducted by using 135 cases of 624 cases. When considering only the elderly and making comparisons between the urban areas and the rural areas the following data was produced. In regard to patients with acute drug intoxication, the main substance of choice was pesticides. Cases of acute drug intoxication are definitely higher for those categorized as the rural elderly (75.0%) when compared with those categorized as the urban elderly (44.1%). The male to female ratio, those living together as a family, past suicide attempts, mental state and sobriety condition when they came, monthly distribution etc. between the two groups did not demonstrate a difference between them. In regard to reasons given for acute drug intoxication, suicide was the highest at 60.7% of the cases. When comparing accidental reasons for poisoning, the urban elderly, at 34.2% of their cases, were higher than in the rural elderly, at 23.7%. After first aid was administered, the admission rate was higher for the rural elderly (47.4%) than for the urban elderly (33.9%). This shows that the rural elderly have a more severe acute drug intoxication poisoning problem than the urban elderly do.
        4,000원
        10.
        2019.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 한국과 미국 방사선학과 대학생들을 대상으로 방사선 정보원과 전공 선택 만족도의 상관 관계를 분석하고자 하였다. 본 연구의 대상자는 한국의 충북 소재의 일개 4년제 대학교와 미국의 텍사스 주 소재의 일개 4년제 대학교의 방사선학과 1, 2 학년을 대상으로 하였다. 설문조사는 2019년 5월 7일부터 5월 28일까지 방사선 정보원과 정보원 신뢰도 그리고 방사선학과 선택 만족도에 대해 자기기입방식으로 조사하였다. 그 결과 첫째, 양국 대학생 모두 인터넷을 가장 많이 사용하는 정보원이지만 교과서를 통한 정보 수집 비중은 미국 대학생들이 유의하게 높았다. 둘째, 한국 대학생들은 미국 대학생들보다 정보원에 대한 신뢰도가 정부의 인쇄물을 제외한 인터넷, 신문, 소셜 네트워크 순으로 유의하게 높았다. 셋째, 미국의 대학생들은 한국 대학생들보다 방사선학과 선택 만족도가 유의하게 높았다. 넷째, 한국 대학생들은 다양한 정보원을 통해 전공 선택에 도움을 받고 있었으며 특히, 소셜 네트워크간의 상관계수가 유의하게 높은 상관관계를 나타냈다.
        11.
        2019.10 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 관전압과 관전류량이 디지털 방사선영상에서 적용되고 있는 노출 지수에 미치는 영향을 알아보고자 하였다. 방사선발생장치는 인버터방식의 디지털 X선 발생장치를 사용했으며 영상검출체는 포터블 형태의 무선 디텍터를 그리드 없이 사용하였다. 방사선영상은 3D 프린터를 이용하여 제작한 원뿔형 피라미드 팬텀을 이용하여 획득하였다. X선의 관전압 조사조건은 40 kVp부터 120 kVp까지 10 kVp 씩 증가시켰고 각 관전압에서 관전류량은 1 mAs에서부터 128 mAs까지 배수적으로 증가시켰다. 그 결과 관전압이 EI와 높은 R2값으로 로그 함수적 관계가 있었으며 관전류량이 매우 높은 선형적인 관계가 있었다. 또한 영상 검출체의 면적선량과 EI도 R2값이 0.76 이상으로 높은 상관관계가 있었다. 결론적으로 관전류량이 EI에 선형적으로 영향을 주었으며, 적절한 영상품질 유지를 위해서는 예측이 용이한 관전류량을 주로 조절하 는 것이 유리하다고 판단된다.
        12.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        국제전기기술위원회의 문서 IEC 60601-1의 3판 규격과 IEC 60601-2-45의 개별 규격에서는 진단용 X선 장치에서 X선 피폭 선량 정보를 표시하고 그 정확성을 명시할 것을 권고하고 있다. 하지만 임상에서 사용 하는 부착형 공기커마 면적선량계는 교정에 어려움이 있다. 이에 본 연구에서는 임상에 적용 가능한 RQR 표준 선질을 이용하여 공기커마 면적선량계의 에너지 의존성과 정확도를 평가하였고 임상에서 간접 교정을 시행할 수 있도록 방법론을 마련하고자 하였다. RQR5의 표준 선질에서 시행한 시험에서 부착형 공기커마 면적선량계는 –7.5%의 오차를 나타냈고, RQR8의 표준 선질에서는 –10.3%의 오차를 나타냈으며 시험한 모든 RQR 선질에 대해 평균 절대오차는 8.30%±2.85%를 나타내 IEC 60580과 AAPM TG 190의 조건을 만족하였다. 본 연구에서 도출한 공기커마 면적선량계의 교정 방법은 임상에서 사용하는 공기커마 면적 선량계의 간접 교정법으로 사용할 수 있을 것으로 기대한다.
        13.
        2018.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 인체 모사 조형물을 3차원 프린팅으로 출력한 사례를 보고하고자 하였다. 재료는 용융적층방식의 개인용 3차원 프린터 장비와 폴리락트산을 소재로 사용하였다. 3차원 인체 모사 조형물 출력은 모델링하는 단계, 평면화 작업과 G-code 변환 단계,출력변수 설정 단계, 3D 출력단계, 마지막으로 후처리 단계 순으로 진행하였으며, 학생들의 학습만족도(해부학인지도, 수업흥미도)를 리커트 5 점 척도로 조사하였다. 그 결과, 총 20가지의 3차원 인체 모사 조형물을 성공적으로 출력하였다. 총 출력소요시간은 11,691분(194시간 85분)이었으며 평균 출력소요시간은 584.55분(9시간 7분)이었다. 이에 소요된 필라멘트량은 총 2,390.2 g 이었으며 평균 119.51 g 이 소요되었다. 학습만족도의 해부학인지도는 평균 4.6 점, 수업흥미도는 평균 4.5 점으로 높은 것으로 나타났다. 앞으로 3차원 프린팅 기술은 영상해부학 교육의 학습효과를 높여줄 수 있으리라 기대한다.
        14.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 평가 하고자 하였다. 의료용 X선은 디지털방사선(digital radiography, DR)시스템을 사용하였다. 최상의 공간분해 능을 도출하기 위해 X선관의 초점크기와 디지털영상후처리 방법을 변화시켰다. 이때 텅스텐을 이용한 에 지방법의 변조전달함수(modulation transfer function, MTF)를 사용하여 선예도(0.5 MTF)와 해상도(0.1 MTF) 를 평가하였다. 그 결과 소초점에서 영상후처리의 대조도를 강화시킨 조건에서 3.871 lp/mm (0.1 MTF)와 3. 290 lp/mm (0.5 MTF)의 공간분해능을 얻었다. 결론적으로 이러한 결과는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 관찰할 수 있었다.
        15.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 비등방성 2차원 확산 기반 필터를 이용하여 전산화단층영상(computed tomography, CT)의 노이즈 제거와 공간분해능을 향상하고자 하였다. 실험은 4-채널 다중검출기 전산화단층영상기기(4-channel multi-detector computed tomography, MDCT)를 이용하였으며, CT 영상품질 평가를 위해 미국 의학물리학자 협의회(american association of physicists in medicine, AAPM) CT 성능 평가용 팬톰을 사용하였다. X-선 조사 조건은 120 kVp, 100 mAs로 고정한 후 ultra-high resolution으로 10 mm 축 방향 스캔 하였다. 본 연구에서 제안한 비등방성 2차원 확산 기반 필터는 원 영상에 각 픽셀에 가중치 1.2를 곱하고 0.4% 히스토그램 스트 레칭을 통해 영상의 대조도를 증가시킨 후 비등방성 2차원 확산 필터를 적용하였다. 그 결과, 공간분해능 은 원 영상에서 0.75 mm까지 구분되었지만 제안한 비등방성 2차원 확산 기반 필터 영상에서는 0.40 mm까 지 구분되었다. 원 영상의 노이즈는 46.0, 제안한 비등방성 2차원 확산 기반 필터 영상의 노이즈는 33.5로 27.2%가 감소하였다. 우리가 제안한 비등방성 2차원 확산 기반 필터는 CT의 노이즈 제거와 공간분해능을 향상시킬 수 있었다.