검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2023.11 구독 인증기관·개인회원 무료
        When storing spent fuel in a dry condition, it becomes essential to ensure that any remaining moisture bound to the canister and spent fuel is effectively removed and stored within an inert gas environment. This is crucial for preserving the integrity of the spent fuel. According to the NRC- 02-07-C-006 report, it is advised to reduce pressure gradually or in incremental stages to prevent the formation of ice. In the context of vacuum drying, it is desirable to perform testing using a prototype model; however, utilizing a prototype model can be difficult due to budget constraints. To address this limitation, we designed and constructed a laboratory-scale vacuum drying apparatus. Our aim was to assess the impact of vacuum pump capacity on the drying process, as well as to evaluate the influence of canister volume on drying efficiency. The vacuum drying tests were carried out until the surface temperature of the water inside reached 0.1°C. In the tests focusing on vacuum pump capacity, vacuum pumps with capacities of 100, 200, 400, and 600 liters were employed. The outcomes of these tests indicated that smaller vacuum pump capacities resulted in increased evaporation rates but also prolonged drying times. In the case of drying tests based on canister volume, canisters with volumes of approximately 100 and 200 liters were utilized. The results revealed that larger canister volumes led to longer drying times and lower rates of evaporation. Consequently, if we were to employ an actual dry storage cask for vacuum drying the interior of the canister, it is anticipated that the process would require a substantial amount of time due to the considerably larger volume involved.
        2.
        2023.11 구독 인증기관·개인회원 무료
        The saturation of wet storage facilities constructed and operated within nuclear power plant sites has magnified the significance of research concerning the dry storage of spent nuclear fuel. Not only do wet storage facilities incur higher operational and maintenance costs compared to dry storage facilities, but long-term storage of metal-clad fuel assemblies submerged in aqueous tanks is deemed unsuitable. Consequently, dry storage is anticipated to gain prominence in the future. Nevertheless, it is widely acknowledged that quantitatively assessing the residual water content remains elusive even when employing the apparatus and procedures utilized in the existing dry storage processes. The presence of residual water can only be inferred from damage or structural alterations to the spent nuclear fuel during its dry storage, making precise prediction of this element crucial, as it can be a significant contributor to potential deformations and deterioration. The aforementioned challenges compound the issue of retrievability, as substantial complexities emerge when attempting to retrieve spent nuclear fuel for permanent disposal in the future. Consequently, our research team has established a laboratory-scale vacuum drying facility to investigate the sensitivity of various parameters, including canister volume, pump capacity, water surface area, and water temperature, which can exert thermohydraulic influences on residual water content. Moreover, we have conducted dimensional analysis to quantify the thermohydraulic effects of these parameters and express them as dimensionless numbers. These analytical approaches will subsequently be integrated into predictive models for residual water content, which will be further developed and validated at pilot or full-scale levels. Furthermore, our research team is actively engaged in experimental investigations aimed at fine-tuning the duration of the pressure-holding phase while optimizing the evaporation process under conditions designed to avert the formation of ice caused by abrupt temperature fluctuations. Given that the canister is constructed from acrylic material, we are able to identify, from a phenomenological perspective, the specific juncture at which the boiling phenomenon becomes manifest during the vacuum drying process.
        3.
        2023.05 구독 인증기관·개인회원 무료
        There is a need to develop a quantitative residual water measurement method to reduce the measurement uncertainty of the amount of residual water inside the canister after the end of vacuum drying. Therefore, a lab-scale vacuum drying apparatus was fabricated and its characteristics were evaluated by performing vacuum drying experiments based on the amount of residual water, vacuum drying experiments based on the surface area of residual water, and vacuum drying experiments based on the energy of residual water using the lab-scale vacuum drying apparatus. As a result of the vacuum drying experiments, if the surface area of water is the same, the greater the amount of water, the greater the energy of the water, so more energy is transferred to the surface of the water. Therefore, more water evaporated, and the average temperature of the remaining water was higher. The larger the surface area of the water, the more energy it takes to vaporize it, so the faster it dries and the faster the drying time. Before ice formed, energy was actively transferred by conduction heat transfer from the top, center, and bottom of the water to provide the energy needed for the water to evaporate from the surface. However, no energy was transferred from the water just before it turned into ice. When vacuum drying water, you can dry more water if you dry it slowly over a longer period of time. Therefore, by using a vacuum pump with a low flow rate, the pressure can be lowered slowly to prevent ice from freezing, thereby improving the drying quantity. It was evaluated that there was a good agreement between the energy used when water evaporated and the energy absorbed from the surroundings to within about 4%. Therefore, if the energy absorbed from the surroundings is known, it is possible to evaluate the amount of water evaporated in vacuum drying.
        4.
        2022.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The safety of a KTC-360 transport cask, a large-capacity pressurized heavy-water reactor transport cask that transports CANDU spent nuclear fuel discharged from the reactor after burning in a pressurized heavy-water reactor, must be demonstrated under the normal transport and accident conditions specified under transport cask regulations. To confirm the thermal integrity of this cask under normal transport and accident conditions, high-temperature and fire tests were performed using a one-third slice model of an actual KTC-360 cask. The results revealed that the surface temperature of the cask was 62°C, indicating that such casks must be transported separately. The highest temperature of the CANDU spent nuclear fuel was predicted to be lower than the melting temperature of Zircaloy-4, which was the sheath material used. Therefore, if normal operating conditions are applied, the thermal integrity of a KTC-360 cask can be maintained under normal transport conditions. The fire test revealed that the maximum temperatures of the structural materials, stainless steel, and carbon steel were 446°C lower than the permitted maximum temperatures, proving the thermal integrity of the cask under fire accident conditions.
        4,000원
        7.
        2020.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Compartment fire tests were performed using kerosene and Jet A-1 as fire sources to evaluate the relationship between flame temperature and opening size. The tests were performed for a fire caused by the release of kerosene owing to vehicle impact, and for a fire caused by the release of Jet-A-1 owing to airplane collision. The compartment fire tests were performed using a 1/3-scale model of a metal storage cask when the flame temperature was deemed to be the highest. We found the combustion time of Jet-A-1 to be shorter than that of kerosene, and consequently, the flame temperature of Jet-A-1 was measured to be higher than that of kerosene. When the opening was installed on the compartment roof, even though the area of the opening was small, the ventilation factor was large, resulting in a high flame temperature and long combustion. Therefore, the position of the opening is a crucial factor that affects the flame temperature. When the metal storage cask was stored in the compartment, the flame temperature decreased proportionally with the energy that the metal storage cask received from the flame.
        4,200원