        22.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at 300 ℃, 400℃, 500℃, 600℃, 700°℃, and 800℃ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.
        4,000원
        23.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 NO96 화물창의 BOG(boil off gas), BOR(boil off rate)을 감소시키기 위한 노력으로 단열재료 및 단열층을 변화시켜서 개발된 NO96-GW, NO96-L03의 방열구조에 대해서 BOG, BOR 값을 계산하고 단열성능을 비교․평가하였다. 두 가지의 변형된 NO96 모델을 기존의 NO96 방열과 단열층 및 단열재료의 차이점을 비교하고, 각각의 열저항 및 BOG/BOR 값의 비교 결과를 제시하였다. 열저항 값은 유한요소해석법을 이용하여 계산되었으며, 준정적 열평형 상태를 가정하여 열유속과 온도분포를 통하여 단열성능을 비교하였다. 계산에 사용된 화물창의 모든 재료물성치는 온도 의존값으로서 반영하여 -163oC에서의 극저온 상태에서 특성을 반영되었다. 각 화물창의 BOG, BOR 계산은 국부 열전달 해석을 통해 방열판에서 발생하는 열유속을 계산하고, 등가모델을 적용하여 계산하는 과정으로 수행되었으며, 그 결과를 각 화물창의 단열성능을 비교평가하기 위해서 검토하였다.
        4,000원
        25.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: Evaluation of the wind speed effect on the temperature drop of an asphalt mixture during construction, by using the transient heat transfer theory and dominant convective heat transfer coefficient model. METHODS: Finite difference method (FDM) is used to solve the transient heat transfer difference equation numerically for various wind speeds and initial temperature conditions. The Blasius convective heat transfer coefficient model is adapted to account for the effect of wind speed in the temperature predictions of the asphalt mixture, and the Beaufort number is used to select a reasonable wind speed for the analysis. As a function of time and depth, the temperature of the pavement structure is predicted and analyzed for the given initial conditions. RESULTS : The effect of wind speed on the temperature drop of asphalt mixture is found to be significant. It seems that wind speed is another parameter to be accounted for in the construction specifications for obtaining a better quality of the asphalt mixture. CONCLUSIONS: It is concluded that wind speed has a significant effect on the temperature drop of the asphalt layer. Although additional field observations have to be made to reflect the effect of wind speed on the construction specifications, it appears that wind speed is a dominant variable to be considered, in addition to the atmospheric temperature.
        4,000원
        26.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Computational algorithms and their implementations are studied for the treatments of kernel function’s shadow effects, which occurs in the application of the BEM(boundary element method) for radiation heat transfer analysis. In this problem, surfaces are assumed to be diffuse and gray placed in two-dimensional enclosures with transparent medium. Self-blocking or third party blocking is possible when the radiosity from the BEM nodes cannot reach the destination points. Also the third party blocking can be the partial or total blocking case. Algorithms, which can accurately recognize the each blocking cases and reflect the shadow effects to the BEM kernel function, are studied in this paper. Effective implementation methods are presented, and their results are verified by the test problem
        4,000원
        28.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to find better performance of heat sink, in this research, different cases were analysed by changing number of slots and shape of fins. Round shape fins which have wide surface showed 24% better heat transfer rate than vertical fins. There were not big discrepancies between 1 slot and 2 slots fins. Consequently, for better performance of heat sink, developments for widening surface and better material for high heat transfer rate are needed.
        4,000원
        29.
        2009.12 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the heat transfer characteristics and energy consumption in the wet and dry ondol systems. Conditions of the continued heating mode set the room temperature at 20℃ and hot water supply temperature at 60℃ and 70℃ for 3 days. The scheduled heating mode operates heating at 6~9am (room temperature at 20℃), suspends heating at 9~18pm (leaving mode), and runs heating at 1 8~24am (room temperature at 20℃) and 24~6am (room temperature at 17℃) for 2 days. The results from the continued heating mode in the dry/wet ondol systems confirmed that the dry and wet systems had the same average indoor temperature (18.9℃) and similar energy consumption. In addition, the results from the scheduled heating mode in the dry/wet ondol systems confirmed that the dry ondol system had lower energy consumption than the wet ondol system. Therefore, the scheduled heating mode in the dry ondol system is expected to reduce energy consumption.
        4,000원
        30.
        2009.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        전해제련 공정은 악티늄족 원소를 동시에 회수하는 공정으로써, Pyroprocessing의 핵확산 저항성을 보장 하는 중요한 공정이다. 공학규모의 전해제련 장치를 설계하기 위한 기본 도구를 개발하기 위해서 실험실 규 모의 장치에 대한 열전달 해석을 수행하였다. 열전달 해석을 수치 해석적으로 계산하기 위해 ANSYS CXF 상 용 코드를 사용하였다. 열전달 해석 결과, 가열부의 길이가 수직으로 용융염의 높이보다 약 3배 이상이 되었 을 때, 용융염의 온도를 일정하게 유지할 수 있었으며, 냉각부의 길이는 그 영향이 미비하였다. 전해조 덮개아래의 아르곤 가스의 온도는 냉각 판의 개수에 따라 감소하였으며, 5개 이상 설치 할 경우 250 ℃ 이하로 유 지할 수 있음을 보였다. 이러한 계산 결과는 실제 실험 장치에서 측정된 장치 내부 온도 분포와 경향성이 일 치하는 것을 볼 수 있었다. 본 연구에서 해석된 전해제련 장치의 열 분포 특성은 공학규모 장치의 설계를 위 해 중요한 자료로 사용 될 수 있을 것이다.
        4,000원
        31.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 계면경계에서 특이성을 갖는 이종재료 열전달문제를 효율적으로 해석할 수 있는 이동최소제곱 유한차분법을 제시한다 이동최소제곱 유한차분법은 격자망(grid)없이 절점만으로 이동최소제곱법을 이용하여 Taylor 다항식을 구성하고 차분식을 만들어 미분방정식을 직접 푼다. 초평면함수 개념에 근거한 쐐기함수를 이동최소제곱 센스(sense)로 근사식에 매입하여 쐐기거동과 미분 점프에 따른 계면경계 특성을 효과적으로 묘사하고 고속으로 미분을 근사하는 이동최소제곱 유한차분법의 강점을 발휘하도록 했다. 서로 다른 열전달계수를 갖는 이종재료 열전도문제 해석을 통해 이동최소제곱 유한차분법이 계면경계문제에서도 뛰어난 계산효율성과 해의 정확성을 확보할 수 있음을 보였다.
        4,000원
        39.
        1995.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        3차원 실내공간의 상부에서 일정유속이 유입하여 양측면 하부쪽으로 유출될 경우, 책상형의 가열 장애물 영향에 의한 유동장의 변화와 온도분포를 수치계산 한 결과 다음과 같은 결론을 얻었다. (1)표준 k-ε 2 방정식 모델로 난류유동장을 해석한 결과 장애물을 기준으로 상하부에는 독립적인 큰 재순환 영역이 존재함을 알 수 있었다. (2) 유입류의 속도 변화에 따른 전제적인 유동패턴은 큰 변화없이 상사적인 분포를 하는 것을 알 수 있었다. (3) 유입속도가 감소함에 따라서, 공간에 대한 발열체의 온도영향이 커진다. (4) Re수가 작은 범위 (10 상(4)-10 상(5)에서는 열전달이 급격히 상승하여, Re수가 10 상(5)이상이 도면 열전달이 거의 일정하다.