검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 39

        21.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        This study analytically reviewed the behavior of Steel Plate Concrete(SC) walls subjected to combined loads of axial force, flexural moment, and shear force to investigate the effects of shape and arrangement spacing of studs on the behavior of SC walls. To perform it, 9 cases of finite element analyses considering the different shape and spacing of studs in SC wall were carried out. The results showed that, for SC walls combined steel plate and concrete according to the Design Code, the compressive strength is higher than the tensile strength. Compared results from the finite element analyses of SC walls subjected to combined loads with Design Code showed that all cases were higher than the design strength. For KEPIC SNG, the moment and shear force were not influenced by the axial force of 0.1 to 0.2 times axial strength, however, from the analyses, it was found that the values were decreased as the axial force is increased.
        22.
        2014.10 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical walls to enhance performance of wall-wall girder connection. The purpose of this study is to investigate the structural characteristics such as strength, Load-displacement relation of wall-wall girder connection under the monotonic load tests. The fracture pattern of the specimens induced positive moment at connection was steel plate separation from concrete in SPC Wall.
        23.
        2014.10 서비스 종료(열람 제한)
        This study analytically reviewed the behavior of Steel Plate Concrete(SC) walls subjected to cyclic shear forces to investigate the effects of shape and arrangement spacing of studs on the design of SC walls. The shape of the stud did not affect the shear behavior of SC wall but, the spacing influenced to its composite action.
        24.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 SC 전단벽의 전단 연결재인 스터드의 배치와 형상이 SC 전단벽의 거동에 미치는 영향을 살펴보기 위해 전단벽체가 전단력과 축하중을 받을 때의 거동을 해석적으로 검토하였다. 이를 위해 서로 다른 형상과 배열의 스터드가 배열된 SC 전단벽을 대상으로 유한요소해석을 수행하였다. 스터드의 간격이 과하게 떨어져 있을 경우 합성거동이 완벽하게 작용하지 못하며 강판이 설계곡선의 2차 항복 전단력 보다 적은 하중에서 항복함을 확인하였다. 스터드의 형상은 일반형 스터드뿐만 아니라 개선된 경사형 스터드도 전단거동에 큰 차이를 나타내지 않았고, 스터드의 간격이 합성거동에 영향을 미침을 확인하였다. 또한 이 연구를 통하여 경사형 스터드가 일반형 스터드에 비해 좌굴을 제어하는데 효과가 있음을 확인하였다.
        25.
        2014.04 서비스 종료(열람 제한)
        This study reviewed analytically the behavior of Steel Plate Concrete(SC) walls subjected to shear forces to investigate the effects of shape and arrangement spacing of studs on the design of SC walls. The results showed that the steel plate was yielded at the lower load than the second yielding shear force of the design skeleton curve when the spacing of stud is excessively far from each other. It is also found that the shape of the stud did not affect the shear behavior of SC wall, however, the spacing influenced to its composite action.
        26.
        2014.04 서비스 종료(열람 제한)
        This study reviewed analytically the behavior of Steel Plate Concrete(SC) walls subjected to axial forces to investigate the effects of shape and arrangement spacing of studs on the design of SC walls. In this study, it was proven that the inclined shaped stud resists more effectively to the bucking load than the general shaped stud in SC wall.
        27.
        2014.04 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical walls to enhance performance of wall-wall girder connection. The purpose of this study is to investigate the structural characteristics such as strength, Load-displacement relation of wall-wall girder connection under the cyclic load tests. The fracture pattern of the specimens was steel plate separation from concrete in SPC Wall induction of tensile crack failure of SPC Wall concrete.
        28.
        2014.04 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical SPC walls to enhance performance of wall-wall girder connection. The fracture pattern of the SPC wall-wall girder connection was steel plate separation from concrete in SPC Wall. The purpose of this study is to theoretical analysis on fracture behavior of the SPC wall-wall girder connection under the monotonic load test inducing positive moment at connection. The Plastic hinge theory on steel plate of SPC wall girder is proposed to explain steel plate separation fracture pattern.
        29.
        2014.04 서비스 종료(열람 제한)
        The domestic research of the steel plate concrete structures have been focused on the nuclear structures that usually reqire large strength. This research tried to establish some basic design information of SC structures using non-cement concrete. This paper studied on the compressive characteristics, effective length factors subjected to the concentrated compression loadings. The effective length factors were calculated by Euler Column Theory rather than using Plate Buckling Theory. The strains which are requird in calculating the effective length factor were measured to caculate the effective length factor at the yield of surface steel plate, the buckling of surface steel plate and the failure of concrete.
        30.
        2014.04 서비스 종료(열람 제한)
        The composite beam is efficient and easy to construction. But shear connector is needed for the composite action. This research developed SPC beam in order to reduce the shear connector with utilization of mechanical bonded force by the cross sectional shape. The flexural behavior of SPC beam was evaluated through two point loading test.
        31.
        2014.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 휨모멘트를 받는 SC 벽체 스터드의 성능을 최적화시키기 위해 비선형 유한요소법을 사용한 해석적 연구를 수행하였다.SC 벽체에 대한 유한요소모형에서는 접촉, 연결, 그리고 재료에 대한 비선형성을 고려하였다. 그리고 해석모형의 검증을 위해 선행된 실내실험을 모사하여 계측결과와 해석결과를 비교하였고, 제안된 해석방법의 타당성을 검증하였다. 문헌조사를 통해 해석 대상물의 크기를 결정하였고, 다양한 스터드의 형식과 배치간격을 고려한 해석을 수행하였다. 또한, KEPIC SNG를 만족하는지에 대한 추가적인 검토를 수행하였다. 최종적으로 수치해석과 기준의 검토를 통하여 개선된 스터드의 최적 형식 및 배치안을 제시하였다.
        32.
        2013.10 서비스 종료(열람 제한)
        In this study, an experimental study to investigate the shear friction behavior of the SC Wall to RC slab connection was carried out. The maximum shear friction capacity and failure mode were examined, and the results were also compared with theoretical value. Finally, the results are to be used for the basic reference of the design guideline(draft) for the RC-SC connection.
        33.
        2012.11 서비스 종료(열람 제한)
        The objective of this study is to assess the structural response and impact energy absorption characteristics of reinforced concrete (RC) and steel plate concrete (SC) barrier walls under missile impact loading considered in the design of NPP (nuclear power plant)'s facilities. The study considered the barrier wall response under external tornado-generated missiles (e.g., steel pipe and automobiles).
        34.
        2012.11 서비스 종료(열람 제한)
        The objective of this study is to develop the reinforcing design method of the NPP (nuclear power plant)'s steel plate concrete (SC) wall for enhancement of impact resistance capacity under the aircraft and missile impact loading considered in the design of NPP's facilities. This study investigated the effects of the several parameters that can affect impact resistance capacity of SC wall using finite element analysis method.(e.g., thickness of concrete and steel plate, material strength of concrete and steel, and other reinforcing design method).
        1 2