검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 32

        21.
        2003.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To comparison the surface treatment methods of stone board materials, the results of Dorry's abrasive test were 23.4 for water-jet system and 18.9 for flame-burner system. Therefore abrasive hardness, the stone board materials by the water-jet system was greater than one by flame-jet system. As a result of Shore's hardness test, the stone board materials by water-jet system was twice greater than one by flame-jet system. Authors carried out microscopic observation to survey a defection of the composition minerals for two methods, but all of the both methods have not founded a defection. Therefore, the stone board materials by water-jet system was greater durability than one by flame-jet for the surface treatment methods.
        4,600원
        22.
        1999.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존의 정수처리 공정인 응집 침전 과정을 대체하여 분리막을 이용한 상수처리 시스템의 개발을 목적으로한다. 따라서 4가지 형태의 정수처리 공정과 분리막의 분획 분자량을 변화시켰을 때 막 투과수의 변화와 안정적이며 높은 투과수를 얻기 위해 필요한 운전 조건의 최적화를 실험하였다 실험결과 한외여과막이 정밀여과막보다 막 투과수 감소경향이 완만했으며 초기 투과수 회복율은 더 높았다. 수질 분석의 결과 한회여과막이 정밀 여과막보다 우수하였지만 전처리에 의한 차이는 나지 않았다. 운전 조건에 따른 flux 는 온도, 선속도가 높을수록 압력이 낮을수록 flux 감소율이 적은 경향을 나타내었다.
        4,000원
        23.
        2017.09 서비스 종료(열람 제한)
        Recently, Advanced water treatment facilities with Ozone are being introduced domestically. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. Therefore, in this study, It was evaluated in Permeability Evaluation of metal spraying coating.
        24.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        선박의 항해 안전성을 유지하기 위하여 평형수 탱크에 주입ㆍ배출되는 선박평형수는 그 안에 포함되어 있는 각종 수중생물로 인하 여 지역 해양 환경에 부정적인 영향을 주고 있다. 국제해사기구(IMO)는 선박평형수를 통한 수중생물의 이동을 막기 위해, 2004년 선박평형수 와 침전물 통제 및 관리를 위한 국제협약을 채택하고 2016년 9월에 발효하여, 2017년 9월 이후 정기검사가 도래하는 모든 선박은 선박평형수 처리장치를 설치하도록 하였다. 선박평형수 처리 방식에는 활성물질을 이용하여 처리하는 전기분해식, 오존식, 약품식과 물리적인 처리방식인 필터, 자외선식 등으로 나누어 지며, 두 가지 방식을 혼용하여 사용하기도 한다. 일반적으로 비용과 효율 면에서 전기분해방식이 우수한 것으로 알려져 있다. 본 논문에서는 직접식 전기분해 선박평형수 처리장치의 기본 원리, 구성 요소, 육상 시험 내용을 고찰하였다. 육상시험은 정부시 험 시설이 설치되어 있는 KIOST 거제분원에서 300m3/h 처리 용량의 장치로 수행하였다. 이 육상시험을 통해 직접식 전기분해 선박평형수 처 리장치가 IMO에서 제시하고 있는 기준을 만족하고 다른 방식에 비해 효율적인 것을 확인하였다.
        25.
        2016.10 서비스 종료(열람 제한)
        Recently, Advanced water treatment facilities with Ozone are being introduced domestically. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. Therefore, in this study, It was evaluated in ozone resistance and bond strength of metal spraying coating.
        26.
        2016.08 KCI 등재 서비스 종료(열람 제한)
        The treatment efficiencies of domestic sewage treatment processes were analysed and assessed to suggest and design a suitable technology for coal seam gas (CSG) water treatment. Two sewage treatment plants (S and G in Busan) were selected. The former operates with standard activated sludge and modified Ludzak Ettinger processes while the later uses the combination of A2/O and gravity fiber filtration. For both plants, the concentrations of BOD, CODMn, T-N and T-P were about 5.0, 19.0, 5.0, 11.0 and 1.0 ppm, respectively, which satisfy the discharge standards. Therefore, although sewage treatment processes seems to be applicable for CSG water treatment, additional processes to remove total dissolved solids and ionic compounds (i.e. bicarbonate) need to be introduced to produce fit-for-purpose water resources for beneficial use (in accordance with Water ACT 2013). This, for the CSG treatment process design, it is necessary to align the operating conditions with merging methods of combinable unit technology obtained from sewage treatment processes.
        27.
        2015.12 KCI 등재 서비스 종료(열람 제한)
        To develop various usable water from coal seam gas (CSG) water that needs to be pumped out from coal seams for methane gas production, a feasibility study was carried out, evaluating and analysing a recent report (Coal Seam Gas Water Management Policy 2012) from Queensland State Government in Australia to suggest potential CSG water treatment options for fit-for-purpose usable water production. As CSG water contains intrinsically high salinity-driven total dissolved solid (TDS), bicarbonate, aliphatic carbon, Ca+2, Mg+2 and so on, it was found that appropriate treatment technologies are required to reduce the hardness below 60 mg/L as CaCO3 by setting the reduction rates of Ca+2, Mg+2 and Na+ concentrations, as well as TDS reduction. Also, Along with fiber filtration and membrane separation, an oxidation degradation process was found to be required. Along with salinity reduction, as CSG water contains organic compounds (TOC: 248 mg/L, C6 -C9: <20 mg/L and C10 - C36: <60 mg/L), compounds with relatively high molecular weights (C10 - C36) need to be treated first. Therefore, this study suggests a combined system design with filtration (Reverse osmosis) and oxidation reduction (electrolysis) technologies, offering proper operating conditions to produce fit-for-purpose usable water from CSG water.
        28.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        This study aimed for evaluating the applicability of the two stage dual media filtration system in field water treatment plant. The field plant of two stage and dual media filtration system was operated for 2 months. Average iron concentrations of the settled water, existing filtered water and second stage filtered water was 0.041 mg/L, 0.007 mg/L and 0.005 mg/L, respectively. Removal efficiency of iron concentration in the second stage is appropriately 35% more than in existing filtered water. Also removal efficiency of residual chlorine in the dual media filtration system is relatively 42.3% more than in existing filtered water due to adsorption of activated carbon, but the removal of ammonia nitrogen by adsorption is insufficient. Average concentrations of THM and chloroform in the settled water are 0.033 mg/L, 0.026 mg/L, respectively and in existing filtered water are 0.023 mg/L and 0.023 mg/L. Average concentrations of THM and chloroform in the dual media filtration system are 0.008 mg/L and 0.013 mg/L. Therefore removal efficiency of THM concentration in second stage is more than 66.4% in existing filtrated water. Also removal efficiency of chloroform in the dual media filtration system is more than 50.0% in existing filtered water because of the adsorption of activated carbon. In this case backwashing period in dual stage system is 4~5 days, but in existing filtration system is 1~2 days.
        29.
        2011.12 KCI 등재 서비스 종료(열람 제한)
        Ecological toxicity testing of the whole-effluent from the ozone ballast water treatment system was conducted as specified in the quality assurance project plans (QAPP). The growth inhibition test with microalgae, acute aquatic toxicity test with the Rotifer reproduction, toxicity test (or population growth) with the Rotifer, survival and growth toxicity test with larval fish and sediment toxicity test with amphipod were carried out to evaluate ecological toxicity on the movile test barge.
        30.
        2007.01 KCI 등재 서비스 종료(열람 제한)
        The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of NO3- and Cl- of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and CHCl3 that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.
        31.
        2006.09 KCI 등재 서비스 종료(열람 제한)
        This research aims to investigate the behavior of organic matter that causes bacterial re-growth and the formation of disinfectant by-products such as THM in water treatment, and to optimize conditions for a more efficient and conventional water facility. THM removed 51 % and 12 % through coagulation/sedimentation and filtration using a selected conventional system. In this experiment, the removal ratio of DOC was highest at 68 % when the Gt value was 42,000 and lowest at 41 % when the Gt value was 30,000. 77-84 % of total DOC was removed during coagulation/sedimentation, and 15-23 % was removed during filtration. When Gt values were between 30,000 and 66,000, over 50 % of high molecular matter above 10 K during coagulation/sedimentation was removed. Turbidity removed 98 % when the Gt value was 66,000. As the Gt value increased, the turbidity removal ratio increased. Turbidity removed over 20 % during the filtration process.
        32.
        2004.12 KCI 등재 서비스 종료(열람 제한)
        선박에서 발생되는 밸러스트수를 전처리하기 위하여 수중에 포함되어 있는 미생물을 복극전해처리시스템을 이용하여 살균처하였다. 전해처리시스템에 유입되는 시료는 정량펌프를 사용하여 상향류로 전극판 사이를 통과하도록 하였으며, 반응시간별로 유량을 조절하여 체류시간을 다르게 하였다. 양극판은 티타늄에 이산화이리듐을 전착한 Ti/Ir02 극판으로 하였으며, 음극판은 스테인리스 스틸판을 사용하였다. 전원공급은 최대 전압이 250V, 전류가 100Amper의 맥류가 전혀 없는 트랜지스트 평활회로를 사용한 D.C. Power Supply를 사용하여 전류밀도를 조절하여 운전하였다. 반응시간에 따라 전류밀도를 0.1~1.0A사이로 변화를 주어 실험한 결과 5초 이내에 E. coli, Bacteria, Bacillus sp.의 미생물이 사멸됨을 확인할 수 있었고, 전극간격은 75mm, 전류밀도 2.0A/dm2, 체류시간을 5초로 하였을 때 제거율이 90%이상이였다. 연구결과를 통하여 밸러스트수 처리에 적용 가능한 기술임을 알 수 있었다.
        1 2