        2022.10 구독 인증기관·개인회원 무료
        Radionuclides stored in a radioactive waste repository over a long period of time might be leached through the barriers such as engineered rock (cement) and natural rock (granite). Organic complexing agents such as ethylenediaminetetraacetic acid (EDTA) and isosaccharinic acid (ISA) may also influence the mobility of radionuclides. In this study, a continuous fixed-column reactor packed with engineered and natural rocks was designed to investigate the effect of organic complexing agents on cesium mobility through cement and granite under anaerobic conditions. The influent flow rate of the mixed solution (organic complexing agent and cesium) at the column bottom was 0.1 mL/min, while that of groundwater was 0.2 mL/min, which was introduced between cement and granite layers in the middle of the column. The hydraulic properties such as diffusion coefficient and retardation factor were derived by a bromide tracer test. The effects of different operating parameters, such as initial cesium concentrations, initial EDTA or ISA concentrations, and bed size, on the cesium adsorption were investigated. The Thomas, Adams-Bohart, and Yoon-Nelson models were applied to the experimental data to predict the breakthrough curves using non-linear regression. These results suggest that organic complexing agents such as EDTA and ISA significantly influence the mobility of cesium in the barriers, indicating that the presence of complexing agents enhances the migration of cesium to the geosphere.
        22.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
        4,000원
        23.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As earthquakes have increased in Korea recently, people are paying attention to the seismic performance of buildings built in the past. Many school buildings in Korea were built based on standard drawings before the seismic design was applied. However, since school buildings are often designated as emergency evacuation facilities in case of disasters such as earthquakes, seismic evaluation and retrofit must be done quickly. This study investigated the failure modes among structural components (beams, columns, and joints), focusing on 1980s standard drawings for school buildings. The effects of column axial force, partial masonry infills, and different material strengths for concrete and rebar were considered for detailed evaluation. As a result, most of the joints were found to be the weakest among structural components. Column axial forces tended to make the joints more vulnerable, and partial masonry infills increased the possibility of joint failure and shear failure in columns.
        4,000원
        24.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 유한요소해석 D/B를 기반으로 보간식을 산출하여 개활지 폭발현상에 의해 기둥에 작용하는 폭압이력을 예측하는 모델을 개발했다. D/B 구성을 위해 7종류 기둥 너비에 대해 총 70회의 유한요소해석을 수행했다. 제안하는 방법의 성능확인을 위해, 기존에 제시된 경험식 기반의 예측식과의 비교연구를 수행했다. 또한, D/B를 구성하는 point 외의 영역에서의 예측 정확도 확인을 위 해 유한요소해석 결과와의 비교/검증 연구를 추가로 수행했다. 제안하는 방법은 기존의 경험식 기반 예측식에 비해 유한요소해석 결 과와 유사한 결과를 산출함을 확인했다.
        4,000원
        25.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The collapse of reinforced concrete (RC) frame buildings is mainly caused by the failure of columns. To prevent brittle failure of RC column, numerous studies have been conducted on the seismic performance of strengthened RC columns. Concrete jacketing method, which is one of the retrofitting method of RC members, can enhance strength and stiffness of original RC column with enlarged section and provide uniformly distributed lateral load capacity throughout the structure. The experimental studies have been conducted by many researchers to analyze seismic performance of seismic strengthened RC column. However, structures which have plan and vertical irregularities shows torsional behavior, and therefore it causes large deformation on RC column when subjected to seismic load. Thus, test results from concentric cyclic loading can be overestimated comparing to eccentric cyclic test results, In this paper, two kinds of eccentric loading pattern was suggested to analyze structural performance of RC columns, which are strengthened by concrete jacketing method with new details in jacketed section. Based on the results, it is concluded that specimens strengthened with new concrete jacketing method increased 830% of maximum load, 150% of maximum displacement and changed the failure modes of non-strengthened RC columns.
        4,000원
        26.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        다가구주택 필로티기둥은 전이구조 형식으로 되어 있어 지진하중에 대하여 전단파괴가 발생하기 쉽다. 이에 따라 내 진설계기준은 강화되고 있지만 이전에 지어진 건축물의 경우 내진보강이 필요한 실정이다. 하지만 기존 습식 공법의 경우 시간 적, 경제적 부담이 크기 때문에 내진보강이 잘 이루어지지 않는다. 따라서 모서리앵글과 CN복합섬유패널을 활용하여 DIY 시공 이 가능한 전단보강공법을 제안하고자 하며 본 실험에서 CN복합섬유패널의 전단성능을 평가하고자 한다. 볼트 연단거리 및 앵 글의 재질을 변수로 설정하여 실험한 결과, 볼트 연단거리가 가까울수록 각형띠판 래티스기둥의 전단내력이 증진되는 것을 확 인하였으며 슬리브 볼트는 고장력 볼트에 비하여 현저히 내력이 저하되어 CN복합섬유패널을 평가하기가 어려웠다. 또한, 알루 미늄앵글은 강재앵글에 비하여 내력은 낮지만 연성능력이 좋은 것으로 평가되었고, 강재앵글은 상대적으로 강성이 크기 때문에 CN복합섬유패널에 주는 영향이 미미한 것을 확인하였다. 이를 실용화하기 위해서 구체적으로 앵글의 크기와 볼트 연단거리를 변수로 설정하여 실험을 수행해야 할 것으로 판단된다.
        4,000원
        28.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.
        4,000원
        29.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems’ joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.
        4,200원
        32.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        According to 「Hwangnyongsa Temple Central Column Record」among the remaining documents, under reconstruction the pagoda of Hwangnyongsa&s 9th floor was completed in July 872 on the lunar calendar. At that time, King Kyeongmun worried about sarira under its central column, saying the central column does not move, and then He ordered to lift the central column. So his servants lifted it on November 6th 872 and checked the sarira and put it back on November 25th on the lunar calendar. 「Hwangnyongsa Temple Central Column Record」did not document how to lift the central column which is tens of meters. therefore, this study inferred the way the central column of the pagoda of Hwangnyongsa was lifted in 872, left as a mystery. For that, this study set various hypotheses and it researched and analyzed hoisting technique that is a way to lift the pagoda of Hwangnyongsa and a column. In conclusion, this study inferred the most suitable hoisting technique for the pagoda of Hwangnyongsa at that time, based on the research and analysis of each chapter.
        4,000원
        33.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        마에는 다양한 기능성 성분이 함유되어 있어서 식용 및 약용으로 다양하게 이용되고 있다. 특히 allantoin은 대표적인 마의 2차 대사산물로서 의약품 및 기능성 화장품 제조에도 활용되는 고부가가치 산물이다. 본 연구에서는 아미노 결합 정지상 HPLC 컬럼을 이용하여 마의 속과 껍질의 allantoin 함량을 분석하였다. Allantoin 표준용액의 검량 선의 결정계수(R2)값은 0.9999로 높은 직진성을 보였으며, 검출한계(LOD)와 정량한계(LOQ)는 각각 0.0229 mg/mL 및 0.0694 mg/mL로 설정되었다. 마 속과 껍질의 건조중량 기준 allantoin 함량은 각각 3.09±0.02 mg/g, 3.91±0.11 mg/g으로 속보다 껍질에 더 많은 allantoin이 함유되어있음을 확인하였다. 따라서 이러한 결과를 토대로 향후 농업부산물인 마껍질이 새로운 고부가가치 기능성 소재로 활용될 수 있음을 확인하였다.
        4,000원
        34.
        2021.06 구독 인증기관 무료, 개인회원 유료
        We determined the composition of water and sediment bacterial assemblages from the East Sea using 16S rRNA gene sequencing. Total bacterial reads were greater in surface waters (<100 m) than in deep seawaters (>500 m) and sediments. However, total OTUs, bacterial diversity, and evenness were greater in deep seawaters than in surface waters with those in the sediment comparable to the deep sea waters. Proteobacteria was the most dominant bacterial phylum comprising 67.3% of the total sequence reads followed by Bacteriodetes (15.8%). Planctomycetes, Verrucomicrobia, and Actinobacteria followed all together consisting of only 8.1% of the total sequence. Candidatus Pelagibacter ubique considered oligotrophic bacteria, and Planctomycetes copiotrophic bacteria showed an opposite distribution in the surface waters, suggesting a potentially direct competition for available resources by these bacteria with different traits. The bacterial community in the warm surface waters were well separated from the other deep cold seawater and sediment samples. The bacteria exclusively associated with deep sea waters was Actinobacteriacea, known to be prevalent in the deep photic zone. The bacterial group Chromatiales and Lutibacter were those exclusively associated with the sediment samples. The overall bacterial community showed similarities in the horizontal rather than vertical direction in the East Sea.
        4,600원
        35.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper aims to develop numerical models for seismically-deficient reinforced concrete columns retrofitted using a fiber-reinforced polymer jacketing system under blast loading scenarios. To accomplish the research goal, a coupling model reproducing blast loads was developed and implemented to the column model. The column model was validated with a past experimental study, and the blast responses were compared to the numerical responses produced by past researchers. The validated modeling method was implemented to the non-retrofitted and retrofitted column models to estimate the effectiveness of the retrofit system. Based on the numerical responses, the retrofit system can significantly reduce the peak dynamic responses under a given blast loading scenario.
        4,500원
        36.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops finite element models for seismically-deficient reinforced concrete building frame retrofitted using fiber-reinforced polymer jacketing system and validates the finite element models with full-scale dynamic test for as-built and retrofitted conditions. The bond-slip effects measured from a past experimental study were modeled using one-dimensional slide line model, and the bond-slip models were implemented to the finite element models. The finite element model can predict story displacement and inter-story drift ratio with slight simulation variation compared to the measured responses from the full-scale dynamic tests.
        4,000원
        37.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        모듈러 건축물은 철근콘크리트 및 철골 구조물에 비하여 상대적으로 경량이고, 단위 모듈간 기둥의 일체성을 기대하기 어려운 구조적 특성을 가진다. 이와 같은 구조적 특성은 모듈러 건축물의 높이가 높아짐에 따라 바람 및 지진과 같은 횡력저항성능에 직접적인 영향을 미친다. 본 연구에서는 횡력저항성능을 향상시키기 위해 긴장재를 활용한 모듈러 구조시스템을 제안하였다. 모듈러 구조시스템을 구성하는 주요 요소인 포스트텐션 기둥-바닥 접합부는 셀프 센터링 거동을 유도하기 위한 형상 및 상세를 가진다. 포스트텐션 기 둥-바닥 접합부의 이력 거동을 상세히 파악하기 위해 유한요소해석을 수행하였으며, 그 결과 초기 긴장력 및 보-기둥 접합부의 접합 조건에 따라 이력 거동은 확연한 차이를 보이는 것으로 나타났다.
        4,000원
        40.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 단조가력 하중을 받는 실물크기 비닐온실의 기둥-서까래-도리 접합부의 역학적거동을 알아보기 위해 현장에서 시공되고 있는 두 가지 형식의 실험체로 구조실험을 수행하였다. 실험결과를 바탕으로 두 가지 형식의 접합부에 대해서 휨성능을 분석하고 접합부 분류를 시도하였다. Type B 는 Type A에 비해 휨 성능이 77% 수준으로 나타났으며 두 형식 모두 강성 및 휨내력이 강접합 수준에 미치지 못하는 것으로 나타났다. 기둥-서까래-도리 접합부의 거동은 용접부 및 체 결구 변형에 의한 국부좌굴이 지배적이었다. AISC 기준에 의한 접합부 분류 결과, Type A와 B 접합부 모두 설계 시 가정하는 강접합 성능에 미치지 못하는 결과를 보였으며 단순 접합으로 분류되는 것으로 나타났다. 따라서 접합부 성능평가 및 분류 결과, 접합부 성능을 고려한 온실 설계가 이루어져야 하며 신뢰성 높은 온실 구조설계를 위해서 온실 접합부에 대한 명확한 설계기준 정립 연구가 필요할 것으로 판단된다.