This research studied the electrical characteristics, IR transmission characteristics, stealth functions, and thermal characteristics of infrared thermal-imaging cameras of copper-sputtered samples. Nylon samples were prepared for each density as a base material for copper-sputtering treatment. Copper-sputtered NFi, NM1, NM2, NM3, NM4, and NM5, showed electrical resistance of 0.8, 445.7, 80.7, 29.7, 0.3, and 2.2 Ω, respectively, all of which are very low values; for the mesh sample, the lower the density, the lower the electrical resistance. Measuring the IR transmittance showed that the infrared transmittance of the copper-sputtered samples was significantly reduced compared to the untreated sample. Compared to the untreated samples, the transmittance went from 92.0–64.1%. When copper sputtered surface was directed to the IR irradiator, the IR transmittance went from 73.5 to 43.8%. As the density of the sample increased, the transmittance tended to decreased. After the infrared thermal imaging, the absolute values of △R, △G, and △B of the copper phase increased from 2 to 167, 98 to 192, and 7 to 118, respectively, and the closer the density of the sample (NM5→NFi), the larger the absolute value. This proves that the dense copper phase-up sample has a stealth effect on the infrared thermal imaging camera. It is believed that the copper-sputtered nylon samples produced in this study have applications in multifunctional uniforms, bio-signal detection sensors, stage costumes, etc.
본 연구에서는 sol-gel법을 이용하여 세라믹 중공사 지지체 표면에 합성된 sol을 dip coating하고 활성층을 형성시켜 한외여과막을 제조하였다. 코팅 횟수 및 코팅 용액의 조성에 따른 코팅층 변화를 확인하여, 결함을 최소화하고 균일하게 제조할 수 있는 조건을 확립하고, 소결 후 투과 특성 측정을 통해 소결 온도의 영향을 고찰하였다. 제조된 한외여과막은 분획분자량(Molecular Weight Cut-Off, MWCO)과 gas-liquid displacement porometer (GLDP), liquid-liquid displacement porometer (LLDP)를 이용하여 기공크기를 측정하고 분리막의 성능과 기공크기의 연관성을 연구하였다.
미세 기공을 갖는 세라믹 중공사막의 기공 크기 및 분포도를 분석하기 위해 gas-liquid displacement porometer(GLDP)와 liquid-liquid displacement porometer(LLDP) 두 가지 측정법을 이용하였다. GLDP와 LLDP를 이용한 기공 크기 측정 및 분석과 관련하여 이론적 고찰을 진행하였고, 10-100 nm의 기공 크기를 갖는 세라믹 중공사막의 기공 크기 및 분포도를 비교 분석하였다. 또한, 서로 다른 기공크기를 가질 것으로 예상되는 세 종류의 세라믹 중공사막의 기공 크기 측정 결과와 수투과도, 배제율 측정 결과를 종합하여 분리막 특성의 연계성을 확인하였다.
뛰어난 물성을 가진 poly (vinylidene fluoride) (PVDF)는 정밀여과 (MF)와 한 외여과 (UF) 분리막의 소재로써 많이 연구되고 있다. 기공의 크기를 조절하는 것은 분리막을 제조하는데 있어 중요한 요소이다. 본 연구에서는 매우 간단한 방법으로 분리막의 기공 크기를 조절하는 새로운 방법을 제시하고자 한다. PVDF 한외여과 분리막의 기공 크기는 유리판 위에 150 ㎛의 두께로 주조된 PVDF 도프 용액이 응고조 (증류수)속으로 들어가는 속도를 통해 조절되었다. 이 때 PVDF 한외여과 분리막의 기공 크기는 응고조에 들어가는 PVDF 도프 용액의 속도가 감소될수록 증가하는 경향을 보였다.
본 연구에서는 입자크기가 다른 3가지 α-알루미나 분체로부터 주입성형법과 소결법을 혼용하여 튜브형 α-알루 미나 지지체를 제조하여 초기 α-알루미나 분체의 입자크기와 소결 온도가 지지체의 기공구조와 기체투과 특성에 미치는 영 향을 고찰하였다. 평균입경이 0.2, 0.5, 1.7 μm인 α-알루미나 분체를 사용했을 시 제조된 α-알루미나 지지체는 각각 약 80, 130, 200 nm의 평균 기공경을 가졌으며 평균 기공경은 소결 온도 보다는 초기 알루미나 분체의 입자크기에 의존하였다. 모 든 시편에서 소결 온도가 증가할수록 지지체의 부피 밀도는 증가하였고 겉보기 기공률은 감소하였다. He, N2, O2, CO2에 대 하여 30°C에서 단일기체 투과 특성을 평가한 결과, 기체 투과도는 기공경 제곱에 비례하여 증가하였고 기공률이 증가함에 따 라서 직선적으로 증가하였다. 이를 토대로 제조된 α-알루미나 지지체의 기체 투과는 점성유동(viscous flow)에 의하여 이루 어지며, α-알루미나 지지체의 기체 투과 특성은 초기 α-알루미나 분체의 입자크기와 소결온도를 제어함으로써 조절될 수 있 음을 확인할 수 있었다.
Ceramics biomaterials are useful as implant materials in orthopedic surgery. In this study, porous
HA(hydroxyapatite)/β-TCP(tricalcium phosphate) composite biomaterials were successfully fabricated using HA/β-TCP powders with 10-30 wt% NH4HCO3 as a space holder(SH) and TiH2 as a foaming agent, and MgO powder as a binder. The HA/β-TCP powders were consolidated by spark plasma sintering(SPS) process at 1000 oC under 20 MPa conditions. The effect of SH content on the pore size and distribution of the HA/β-TCP composite was observed by scanning electron microscopy(SEM) and a microfocus X-ray computer tomography system(SMX-225CT). These microstructure observations revealed that the volume fraction of the pores increased with increasing SH content. The pore size of the HA/β-TCP composites is about 400-500 μm. The relative density of the porous HA/β-TCP composite increased with decreasing SH content. The porous HA/β-TCP composite fabricated with 30%SH exhibited an elastic modulus similar to that of cortical bone; however, the compression strength of this composite is higher than that of cortical bone.
Fe-Cr-Al powder porous metal was manufactured by using new electro-spray process. First, ultra-finefecralloy powders were produced by using the submerged electric wire explosion process. Evenly distributed colloid(0.05~0.5% powders) was dispersed on Polyurethane foam through the electro-spray process. And then degreasing andsintering processes were conduced. In order to examine the effect of cell size (200 µm, 450 µm, 500 µm) in process,pre-samples were sintered for two hours at temperature of 1450˚C, in H₂ atmospheres. A 24-hour thermo gravimetricanalysis test was conducted at 1000˚C in a 79% N₂ + 21% O₂ to investigate the high temperature oxidation behavior ofpowder porous metal. The results of the high temperature oxidation tests showed that oxidation resistance increased withincreasing cell size. In the 200 µm porous metal with a thinner strut and larger specific surface area, the depletion ofthe stabilizing elements such as Al and Cr occurred more quickly during the high-temperature oxidation compared withthe 450, 500 µm porous metals.
비대칭 폴리비닐리덴플루오라이드(PVDF) 막을 상전환법으로 제조하였다. 도포용액은 PVDF를 용매인 N-ethyl-2-pyrrolidone (NMP)와 비용매인 1,4-dioxane, diethyleneglycol dimethyl ether (DGDE), acetone, (equation omitted)-butyrolactone(GBL)의 혼합용매에 녹여서 제조한다. 여러 첨가제가 도포용액 특성, 투과특성과 막 구조에 미치는 영향을 조사하였다. 응고제인 물과 1,4-dioxane, DGDE, acetone과의 상용성이 NMP보다 낮아서 기공크기가 작아진다. 첨가제의 양을 조절하여 기공크기를 변화시켰다. 혼합용매(수계 및 비수계)가 막의 투과성능에 미치는 영향을 살펴보았다. 용액점도뿐만 아니라 표면장력도 용매 투과특성에 영향을 끼침을 알 수 있었다.
벼의 기공 분포 밀도에 미치는 규소의 영향을 구명코자 동계 온냉조절온실에서 규소 농도를 달리하여 수경재배한 벼 제 7 엽기의 엽신 부위별 기공수 및 기공세포 크기를 관찰한 결과 규소 농도 증가로 밀양2003 엽신중 기공수가 줄어들고 엽의 전 표면적에 대한 기공수 기공세포 크기로 나타낸 기공세포의 분포 밀도가 낮게 되어 양면 표피의 cuticle-silica 2중층의 존재 이외에도 수분경제면에서 유리한 특성을 갖게 될 것으로 간주되었다.