With the increasing attention to environmental pollution caused by particulate matter globally, the automotive industry has also become increasingly interested in particulate matter, especially particulate matter generated by automobile brake systems. Here, we designed a coating composition and analyzed its mechanical properties to reduce particulate matter generated by brake systems during braking of vehicles. We designed a composition to check the mechanical properties change by adding Cr3C2 and YSZ to the WC-Ni-Cr composite composition. Based on the designed composition, coating samples were manufactured, and the coating properties were analyzed by Vickers hardness and ball-on-disk tests. As a result of the experiments, we found that the hardness and friction coefficient of the coating increased as the amount of Cr3C2 added decreased. Furthermore, we found that the hardness of the coating layer decreased when YSZ was added at 20vol%, but the friction coefficient was higher than the composition with Cr3C2 addition.
In this study, considering the expansion/contraction behavior of the upper structure at all times and the abnormal behavior of the receiving friction elements that allow horizontal movement during earthquakes, a port receiving test body simulating the protrusion of the friction elements was created and the modulus performance was evaluated. In order to confirm the influence of the friction element's projection, the friction element's degree of separation was divided into four stages, and the shear behavior of the test specimen and the friction coefficient were confirmed. As a result of the experiment, it was found that the friction load increases as the protrusion degree of the friction element increases. On the other hand, as the degree of protrusion of the coefficient of friction increases, the coefficient of friction also increases. It was confirmed that damage to the friction elements during use increases the coefficient of friction, hinders smooth expansion and contraction of the upper structure, and causes stress concentration at the fixed-end support.
구조물의 지진 피해 감소를 위한 내진 시스템 중에서 면진 시스템은 효율적으로 내진 성능을 향상시킬 수 있는 구조 시스템이다. 면진 시스템은 지반과 구조물을 분리시키는 만큼 안전성이 뛰어나지만, 사용되는 장치의 계열에 따라 연직 및 수평 하중에 대한 지지력과 요구변형량에 대한 복원력이 부족하여 파손이 발생할 수 있다. 본 연구에서는 면진 시스템의 성능 개선을 위해 기존 연구에서 제안한 면진 장치의 지지력과 복원력을 향상시킨 고무 마찰 베어링 장치에 대하여 실험 및 해석을 통한 성능 검증 연구를 수행하였다. 이를 위해 고무 마찰 베어링 장치의 설계 상세를 재정립하고 요구 성능에 따른 구조 실험을 수행하여 장치 특성을 검증하였다. 또한, 실험 결과의 신뢰성 향상을 위한 유한요소해석을 수행하여 실험 결과와 유사한 성능 수 준의 장치 특성을 확인하였다.
본 논문에서는 이중질량을 갖는 랙시스템의 마찰거동을 고려한 지진응답해석 기법에 관하여 연구하였다. 마찰 거동을 모사할 수 있는 비선형 동적 시간이력해석 알고리즘을 개발하였다. 이중질량체 간의 미끄러짐과 일체화거동은 비선형 마찰모델로서 고려하였으며, 이를 적절히 모사하기 위한 수치해석기법을 개발하였다. 개발된 알고리즘을 이용하여 랙시스템의 지진응답에 대한 매개변수연구를 수행하였다. 랙시스템의 피해에 큰 영향을 미칠 것으로 예상되는 주요 인자로 랙구조체 질량에 대한 적재질량체의 질량비와 두 질량체 사이의 마찰 계수를 선정하고, 질량비와 마찰계수를 변화시켜 가면서 최대 변위응답의 경향성을 분석하였다. 수치 모사 결과로 부터, 이중질량으로 모델링된 랙시스템의 변위응답은 구조물의 고유진동수가 커질수록 감소하는 경향을 확인할 수 있었다. 이 연구를 통하여 제시하는 방법은 랙시스템의 마찰거동을 미끄러지는 거동을 적절히 모사할 수 있으며, 이로부터 내진 성능평가를 위한 효율적 수치해석 기법으로 활용될 수 있을 것으로 판단된다.
In order to use PUR/CuO Composites as the sealing materials for ships equipment, this research has been performed. PUR/CuO composites are produced by using ultrasonic waves. The increase of CuO leads to increase in the tensile strength and shore hardness. The cumulative wear volume shows a tendency to increase in proportional to sliding distance. As the CuO particles of these composites indicated, the friction coefficient was slightly increased. The major failure mechanisms were lapping layers, deformation of matrix, plowing, debonding of particles and microcracking by scanning electric microscopy photograph of the wear tested surface.
In order to improve seismic safety of nuclear power plant (NPP) structures in high seismicity area, seismic isolation system can be adapted. In this study, friction pendulum system (FPS) is used as the seismic isolation system. According to Coulomb‘s friction theory, friction coefficient is constant regardless of bearing pressure and sliding velocity. However, friction coefficient under actual situation can be changed according to bearing pressure, sliding velocity and temperature. Seismic responses of friction pendulum system with constant friction and various velocity-dependent friction are compared. The velocity-dependent friction coefficients of FPS are varied between lowand fast-velocity friction coefficients according to sliding velocity. From the results of seismic analysis of FPS with various cases of friction coefficient, it can be observed that the yield force of FPS becomes larger as the fast-velocity friction coefficient becomes larger. Also, the displacement response of FPS becomes smaller as the fast-velocity coefficient becomes larger.
The new rotary friction damper was developed using several two-nodal rotary frictional components with different clamping forces. Because of these components, the rotary friction damper can be activated by building movements due to lateral forces such as a wind and earthquake. In this paper, various dependency tests such as displacement amplitude, forcing frequency and long term cyclic loading were carried out to evaluate on the structural performance and the multi-slip mechanism of the new damper. Test results show that the multi-slip mechanism is verified and friction coefficients are dependent on displacement amplitute and forcing frequency except long term cyclic loading.
Dry sliding wear behavior of electro-pressure sintered Co-Fe and Co-Ni compacts was investigated. Pin-on-disk wear tests were performed on the sintered Co-Fe, Co-Ni disks against alumina balls at various loads ranging from 3N to 12N. A constant sliding speed of 0.1m/sec was employed. Wear rate was calculated by dividing the weight loss of a specimen by the measured specific gravity and sliding dis-tance. Worn surfaces and cross-sections of the specimens were examined using an SEM and EDS to investigate wear mechanism of the compacts. The wear behavior of the compacts were discussed as a function of their com-position. Effects of mechancial properties of the compact as well as oxide layers formed on wearing surface on the wear were also discussed
Reactive DC magnetron sputtering 법으로 AISI 304 스테인레스강 기판 위에 TiN 극박막을 50nm∼700nm 두께로 증착한 후, 경화된 AISI 52100 강과 알루미나를 마모 상대재로 하여 박막의 미끄럼마모 시험을 상온 대기 중에서 행하고, 마모 상대재에 따른 TiN 극박막의 마찰과 마모 거동을 연구하였다. AISI 52100 강구를 마모 상대재로 한 경우, TiN 박막은 200g 이하의 마모 하중과 0.035m/sec의 낮은 미끄럼 속도 조건에서 500nm 내외의 극박으로도 마찰계수가 0.1 내외로 유지되는 우수한 내마모성을 보였다. 이같이 우수한 내마모성은 AISI 52100 강으로부터 천이된 Fe가 산화되어 TiN 박막 표면에 Fe 산화층을 형성한 때문으로 설명되었다. 그러나, 마모 상대재를 알루미나 볼로 한 경우에는 TiN 박막 위에 산화층이 형성되지 않고, 마모가 거의 되지 않는 알루미나 볼과 박막층 사이에 국부적 응력집중 등이 발생하여 시험된 전 조건 하에서 박막층의 박리 현상이 관찰되었고 높은 마찰계수가 측정되었다. 또한 기판의 평균 표면조도, Ra가 박막의 두께와 유사할 때 마찰계수가 급격히 상승하는 현상이 관찰되었다.
본 연구는 지진격리장치의 일종인 마찰 단진자 시스템(FPS)의 교량에의 적용에 관한 연구이다. FPS에 의하여 지진 격리된 교량과 지진 격리되지 않은 교량의 지진하중 작용시의 응답을 비교하기 위하여 축소모델 교량을 이용한 진동대 실험을 수행하였다. 연구결과, 본 장치를 설치한 경우 지진하중에 대한 지지능력이 향상하는 것으로 나타났다. 또한, 활동면 곡류반경에 의해 조절이 가능한 F.P.S 베어링의 강성은 입력된 kwlsfur의 강도와는 무관하며, 활동면의 마찰계수에 따라 속도가 변화하여 약진시에는 활동면에서의 속도가 작으므로 강진시와 비교하여 지진하중에 의하여 발생하는 마찰력도 감소하게 되었다. 한편 F.P.S 베어링의 마찰특성은 반복된 실험에서도 변화하지 않았고, 영구변형은 약적으로도 작았을 뿐만 아니라 누적되지도 않았다.
Si-Cr계 내열강 SUH3와 Cr-Ni계 stainless강 SUS 303 및 이들이 마찰용접재 SUH3-SUS303을 1,060℃에서 용체화처리하고 다시 700℃에서 10, 100시간 시효열처리한 각 시험편의 고온 피로강도에 대한 시효열처리의 효과를 알기 위하여 700℃에서 고온 회전굽힘 피로시험을 하고 파약거동을 미시적으로 관찰하여 다음과 같은 결과를 얻었다. 1) SUH3재와 SUS303재의 최적마찰용접조건은 회전수 2420rpm, 마찰가압력 8kg/mm2, 전 upset량 7mm(마찰가압시간 3sec, upset시간 2sec)이었다. 2) 700℃ 고온에서 장시간 이루어지는 고온피로시험에 있어, 용체화처리재의 S-N 곡선 경사부의 기울기가 가장 급하게 나타났다. 3) SUH3-SUS303 마찰용접재는 1,060℃에서 1시간용체화 처리하고, 700℃에서 시효처리하는 경우 최적시효시간은 10시간이었다. 4) 10시간 시료재의 고온피로한도는 모재보다 SUH3은 75.4%, SUS303은 28.5% 높았으며, 용접재 SUH3-SUS303은 44.2% 정도 높았다. 100시간 시효재는 모재보다 SUH3은 64.91% SUS303은 30.4% 높았으며, SUH3-SUS303은 30.4% 높았으며, SUH3-SUS303은 36.6% 높았다. 5) 마찰용접재의 상온 및 고온의 피로파단은 모두 SUS303의 모재측에 발생하였으며, 용접면에서의 파단은 전혀 없었다. 6) SUS303재와 마찰용접재 SUH3-SUS303재의 크랙은 입내파양형이었으나 SUH3은 입계크랙의 전파로 파양한다.
수직거동 마찰댐퍼 시스템의 내진보강공법의 유효성을 판단하기 위해 제진장치의 반복가력실험과 1980년대 비내진 상세를 가지는 R/C건축물을 대상으로 하는 실물 2층 골조를 제작하여 유사동적실험을 실시하였다. 실험결과 수직거동 마찰댐퍼 시스템으로 보강된 실험체는 동일 가속도(200 gal)에서 기준 실험체 대비 최대하중은 약 1.6배 증가하였고, 응답변위는 0.4배로 저감되어 본 연구에서 개발된 수직거동 마찰댐퍼 내진보강공법의 유효성이 검증되었다.
The failure of piping in nuclear power plants and various plant facilities is mainly caused by vibration due to fluid pressure, dead load, temperature expansion and earthquake load in the pipe. Repeated stresses due to vibration cause local fatigue failure on pipe joints where stress is concentrated, which is a factor that hinders the safety of the structure. Therefore, the vibration problem is solved by installing devices to solve the vibration problem in the pipe where vibration frequently occurs. In this study, we developed a damper that damps the dynamic load generated by piping using the friction pendulum principle, and analyzed the behavior curve of the MER-Spring specimen to be used.
This experimental study showed that the shear friction strength that the joint regions of hybrid steel-reinforced concrete beam systems was increased by the dowel bars.
이 논문에서는 원자력발전소나 각종 플랜트 시설물에서 배관을 보호하기 위하여 마찰방식을 이용한 댐퍼를 개발하여 성능을 분석 하는 연구를 수행하였다. 마찰방식댐퍼는 MER-Spring에 압축력을 가하여 베어링과 샤프트에 마찰력을 발생시켜 진동을 감쇠시키는 장치이 다. 댐퍼의 성능을 분석하기 위하여 MER-Spring과 마찰재의 재료특성을 분석하고, 마찰의 영향에 대한 연구를 수행하였으며, 이에 대한 거동 방정식을 수립하였다. 또한 재료의 변형 여부를 판단 및 수립된 거동방정식의 신뢰성 검토를 위하여 시작품을 제작하였고 시편으로 제작된 댐 퍼의 성능 시험과 유한요소 해석을 통하여 이를 분석하였다. 그 결과, 재료의 신뢰성이 확인되었고 마찰계수는 속도에 따른 보정이 필요하며, 반복재하 실험 및 유한요소해석 결과 우수한 결과를 나타냄을 확인하였다. 또한, 추후에 동적하중에 대한 검토가 수행되어 이 연구의 성과가 더 넓은 범위에 적용되었으면 한다.
In this paper, to protect the piping in nuclear power plants and various plant facilities, we have developed a damper using the friction method and carried out a study to analyze the performance. Friction typed damper means a device for attenuating vibration by generating a frictional force to the bearing and the shaft by applying a compressive force to the MER-Spring. In order to analyze the performance of the damper, the properties of MER-Spring and friction materials were analyzed, a study on the effects of friction was carried out, and the behavior of this equation was established. And, to determine whether deformation of the material and to examine the reliability of the behavior of equation established, prototypes was produced and, through a performance test and finite element analysis of a damper made of specimens, they were analyzed.
In this study, an experimental study to investigate the shear friction behavior of the SC Wall to RC slab connection was carried out. The maximum shear friction capacity and failure mode were examined, and the results were also compared with theoretical value. Finally, the results are to be used for the basic reference of the design guideline(draft) for the RC-SC connection.