Recently, the use of transfer slab system has increased greatly. However, several construction problems are being encountered owing to its excessive thickness. Therefore, in this study, a transfer slab system that uses a reverse drop panel, which can utilize the facility space of the pit floor by reducing the transfer slab thickness, was considered. To investigate the shear behavior of transfer slab system that uses the reverse drop panel, the two-way shear strength of transfer slab-column connection with the reverse drop panel was analyzed using nonlinear FE analysis. In addition, the two-way shear strength evaluations of transfer slab with the reverse drop panel conducted using the existing evaluation methods were verified by comparing the strengths predicted by those methods with the results of nonlinear FE analysis.
최근 국내에서는 고층 벽식 아파트 건설 시, 하부 주차공간과 공용공간 확보를 위하여 RC 전이슬래브 시스템을 사용하는 경우가 증가하고 있다. 하지만 두께가 얇은 RC 무량판 슬래브를 위해 개발된 설계방법 및 구조성능평가 방법을 두께가 매우 두꺼운 전이슬래브 구조설계에 그대로 사용하고 있다는 문제점이 있다. 따라서 합리적인 전이슬래브의 구조설계를 위해서는 RC 전이슬래브 시스템의 2면 전단거동 양상에 대한 명확한 분석이 필요하다. 이에 따라 본 연구에서는 전이슬래브의 두께, 콘크리트 강도, 전단경간비, 철근비 등 다양한 설계변수에 따라 비선형 FEM을 이용하여 전이슬래브의 2면 전단거동을 분석 하였다. 또한 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교분석하여 기존 평가식의 전이슬래브 2면 전단강도 평가 유효성을 검토하였다.
Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.
An experimental study was carried out to evaluate the punching shear performance of H-steel column + RC slab system for vertical load. Three specimens were constructed for interior column-slab system. All specimens were the same configuration and material properties except for columns such as RC column+flat plate slab and H-Steel column+flat plate slab. From the test results structural characteristics (maximum proof stress, maximum displacement, deformation capabilities and so on) are obtained and evaluated.
The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.
In this study, an experimental research was conducted to investigate the effective compressive strengths of slab-column connections with different strengths. From the test results, it was found that the effective compressive strengths of the interior columns completely restrained by slab were similar to the compressive strengths of the columns.
Finite element analysis is conducted for investigation of structure behavior of high strength concrete(HSC) column-normal strength concrete(NSC) slab connection according to aspect ratio(h/c). Analysis method is verified through comparison of experiment and analysis. As a result, regarding to the aspect ratio, the ultimate strength of column-slab connection decreased as the column dimension increased while the slab thickness did not influence on the ultimate strength of the connection.
In this study, rational prediction models for the effective compressive strengths of HSC corner and interior columns with intervening NSC slabs are developed. A structural analogy between HSC column-NSC slab joint and brick masonry is used to develop the prediction models. In addition, the aspect ratio of slab thickness to column dimension and the surrounding slab confinement effect are considered in the models. The proposed prediction model is verified by comparison with experimental results and various prediction expressions. As a result, with average test-to-predicted ratios of 1.00 for HSC corner columns and 1.09 for interior columns, the proposed equation provides superior predictions over all of the existing effective strength prediction approaches including KCI structural concrete design code(2012).
In this study, experimental research was carried out to study the structural performance of slab-column joints designed by the application of reducing of joint regions damage using steel fiber reinforced concrete.
Test results showed that specimens(RCFPS series) were increased the maximum load-carrying capacity by 1.12~1.23 times and showed stable hysteresis behavior in comparison with the standard specimen(SRCFP).
풍하중 및 지진하중등 횡하중이 작용하는 무량판 슬래브는 전단파괴와 같은 취성파괴를 지연시키기 위해서 충분한 전단강도와 연성능력을 보유하여야 한다. 본 연구에서는 반복 횡하중을 받는 무량판 슬래브의 전단강도와 변형성능을 고찰하기 위하여, 무보강 및 전단 보강된 총 4개의 내부기둥-슬래브 접합부를 실험하였다. 실험결과, 전단보강 슬래브의 이방향 전단강도는 무보강 슬래브보다 최대 1.5배까지 증가시켜 적용하는 콘크리트구조설계기준(KCI)과 ACI 318-02 기준은 중력하중만이 작용하는 경우에는 적절하나 조합하중 특히 횡하중의 영향이 클 경우에는 매우 불안전측 이었다. 한편, 변형성능 측면에서 슬래브-기둥 접합부의 1.5% 횡변위 성능을 확보하기 위하여 이방향 전단강도에 대한 중력하중비를 40%이하로 제한한 ACI-ASCE 352 위원회의 권고는 안전측인 것으로 나타났다.
연구는 플랫 플레이트 구조에서 직사각형 외부기둥-슬래브 접합부의 뚫림전단강도에 관한 실험결과에 관하여 다룬다. 직사각형 기둥의 형상비 증가에 따른 뚫림전단거동을 평가하기 위해 위험단면의 길이를 일정한 값이 되도록 기둥 단면크기를 산정하고 총 8개의 실험체를 계획하였다. 두 수준의 콘크리트 압축강도(f'c=24, 40MPa)에 대하여 기둥단면의 형상비(βc=C1
본 연구에서는 거주형 무량판 구조의 뚫림 전단을 방지하기 위한 연속 절곡된 전단 보강근을 개발하였다. 이를 적용한 슬래브-기둥 접합부에 있어 개발 전단 보강근의 뚫림 전단 성능을 평가하기 위하여, 구조 성능 실험을 수행하였다. 실험 변수는 전단보강근이 없는 경우, 개발 전단보강근을 사용한 경우, 헤드 스터드를 사용한 경우이다. 수평하중에 대한 저항성능을 평가하기 위하여 일정축력하에서의 이력 하중 실험을 수행하였다. 실험결과는 전체 변위 및 접합부 강도 등으로 평가되었다. 이러한 결과로부터, 개발된 전단보강근이 층간변위비 거동에 있어 우수한 성능을 보유함을 확인할 수 있었다.
플랫 플레이트 구조에서 고강도 콘크리트를 사용함에 따라서 접합부의 전단강도와 같은 구조성능을 향상 시켜서 플랫 플레이트 구조의 단점을 보완하여 장점을 극대화시킬 수 있다고 판단된다. 이에 본 논문에서는 70MPa급 고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥․슬래브 접합부 실험체를 제작한 후에 수직하중과 수평하중의 조합하중을 가력하여 플랫 플레이트 구조의 기둥․슬래브 접합부에 대한 전단강도를 비롯한 주요한 구조성능을 평가하고자 한다. 본 연구에서의 실험변수는 슬래브의 철근비와 슬래브에 작용하는 수직하중의 비율로 하였다.