FRP is a new material that has light, high strength and high durability characteristics and is emerging as a third construction material in and out of countries. However, very few studies have been done on curved FRP construction materials that can be used for tunnels or arched bridges. In particular, many joints are required for the application of curved panels to the open cut tunnel. Experimental data on the performance of the joint is required due to insufficient design criteria. The purpose of this study is to analyze the structural performance of real size, composite materials curved panels. To achieve this goal, curved panels were constructed and bending performance was tested. A numerical analysis was also performed and compared with the results of the test. The results of the test showed that the average load was 757.6 kN and the average displacement of bottom was measured at 53.12 mm. Compression stress on the upper flange and tensile stress on the lower flange were within acceptable limits of 50% of the allowable stress.
복층터널의 중간슬래브는 터널 라이닝에 브래킷을 설치하여 그 위에 거치되는 구조이므로, 브래킷의 파손 시 중간슬래브 낙하 및 라이닝 손상에 따른 인적, 물적 피해가 크게 발생할 수 있기 때문에 브래킷의 설계는 복층터널에서 매우 중요한 사항이라고 할 수 있다. 따라서 본 연구에서는 복층터널의 중간슬래브 지지를 위한 브래킷의 설계와 이의 적용성 검증을 위한 실험 계획을 수립하였다. 중간슬래브의 브래킷은 총 4 종류로 구분하여 설계하였으며, 이는 일반 구간, 팽창줄눈 구간, 비상대피시설로 계단 구간, 비상대피로 차로 구간이다. 브래킷은 차량 진행방향으로 연속적으로 설치하는 방법과 줄눈을 설치하여 불연속적으로 설치하는 방안이 있다. 연속적으로 설치할 경우 구조적으로 더 안정적이지만 브래킷의 유지보수 시 부분적으로 보수를 수행하기 어렵기 때문에 2m 간격으로 줄눈을 설치하는 것으로 설계하였다. 설계에 대한 검증을 위하여 실험계획을 수립하였다. 그림 1과 같이 라이닝의 양단에 브래킷을 설치하여 반력벽 없이 브래킷 설계에 대한 검증 실험을 수행할 수 있도록 하였으며, 상사비 0.5를 적용한 축소 실험체를 제작하여 파괴 형상까지 분석할 수 있도록 하였다. 실험체의 제작 과정을 그림 2에서 보여주며, 향후 하중 재하에 따른 거동 분석 실험을 수행할 계획이다.
신개념 철근콘크리트 포장(ARCP: Advanced Reinforced Concrete Pavement)은 균열유도장치를 이용하여 원하는 위치에 균열을 유도하고 연속철근 콘크리트 포장(CRCP)의 거동에 영향을 미치지 않는 균열 사이의 종방향 철근을 다수 제거하여 철근 사용량을 대폭 감소시키는 포장 공법이다. ARCP 공법의 주요 요소 기술의 하나인 균열유도는 균열유도장치의 형상, 설치깊이, 콘크리트와의 부착유무에 따라 균열의 진전 및 거동에 차이가 발생할 수 있다. 따라서 본 연구에서는 최적의 균열 유도를 위한 방안을 마련하고자 균열유도장치의 형상, 설치깊이, 콘크리트와의 부착 유무에 따른 유도균열을 형성하여 각각의 거동을 계측 및 분석하였다. 그림 1과 같은 야드 실험체에 7종류의 서로 다른 균열유도장치를 설치하였으며 유도균열의 거동 측정을 위한 균열게이지를 설치하였다. 거동 계측은 균열발생 초기부터 균열폭 및 슬래브 온도를 측정하였으며, 계측 10일차부터 20일까지의 데이터를 분석하였다. 균열폭 거동을 그림 2에 나타내었다. 균열폭 거동이 크게 발생하는 균열유도장치는 균열유도장치와 콘크리트가 부착되지 않은 경우(C4)와 콘크리트 다짐을 위하여 균열유도장치의 면적이 작은 경우(C5)인 것으로 나타났으며, 가장 작은 균열폭 거동이 나타나는 것은 비닐을 삽입하였던 경우(C6)인 것으로 나타났다. 균열유도장치의 형상 및 설치깊이, 콘크리트와의 부착 유무에 따라 균열폭 거동에 다소 차이는 발생하지만 모든 경우에서 균열폭이 0.1mm 이하의 작은 거동이 발생하는 것으로 보아 계획한 균열유도장치는 모두 사용이 가능한 것으로 분석되었다.
This paper focused on the application of finite element model updating technique to evaluate the structural properties of the reinforced concrete specimen using the data collected from shaking table tests. The specimen was subjected to six El Centro(NS, 1942) ground motion histories with different Peak Ground Acceleration(PGA) ranging from 0.06g to 0.50g. For model updating, flexural stiffness values of structural members(walls and slabs) were chosen as the updating parameters so that the converged results have direct physical interpretations. Initial values for finite element model were determined from the member dimensions and material properties. Frequency response functions(i.e. transfer functions), natural frequencies and mode shapes were obtained using the acceleration measurement at each floor and given ground acceleration history. The weighting factors were used to account for the relative confidence in different types of inputs for updating(i.e. transfer function and natural frequencies). The constraints based on upper/lower bound of parameters and sensitivity-based constraints were implemented to the updating procedure in this study using standard bounded variable least-squares(BVLS) method. The veracity of the updated finite element model was investigated by comparing the predicted and measured responses. The results indicated that the updated model replicates the dynamic behavior of the specimens reasonably well. At each stage of shaking, severity of damage that results from cracking of the reinforced concrete member was quantified from the updated parameters(i.e. flexural stiffness values).
본 연구는 철근콘크리트 특수모멘트골조(SMF)내 보-기둥 접합부의 비탄성 회전능력에 대한 연구결과를 조사한 것이다. 모든 실험체들은 ACI 318-02에 정의된 설계 및 세부지침에 따라 특수모멘트골조로 분류되었다. AISC(2002)기준에서 모멘트골조의 접합부에 대한 내진성능의 만족 기준을 이용하여 보-기둥 접합부를 평가하였다. 총 39개의 실험체들에 대해 자세하게 조사되었다. 특수모멘트골조에 대한 내진설계기준을 만족하는 대부분의 접합부들은 3%의 소성회전까지 휨강도의 심각한 감소 없이 연성이 유지되었다. 이는 특수모멘트골조 접합부들에 대한 엄격한 콘크리트 내진설계 규정에 따른 것으로 조사되었다. 접합부내의 횡방향 보의 존재는 보-기둥 접합부의 구속력과 전단에 대한 저항성을 증가시킨 것으로 조사되었다 접합부 전단응력에 대한 ACI 328-02 제한조건을 만족하는 모든 특수모멘트골조의 접합부들은 요구되는 내진성능을 만족하는 것으로 나타났다.
This paper proposes substructuring method using experimental model of only upper MDOF structure and verifies its applicability to shaking table test. The structure considered in the test is a five-stoty shear type building model which is divided into two parts, of which one is lower three floors for a numerical substructure and the other is upper two floors for a experinlental substructure. The experimental substructure is excited by the shaking table and the acceleration data for the input of shaking table is obtained numerically from lower numerical part. For implementation of the proposed substructuring method, a controller of the shaking table is designed reflecting experimental model. In comparison with acceleration responses, which are measured from experinlental part of 3rd, 4th, and 5th floor and are numerically calculated from the original five-stoty structure, it is observed that the experimental results match well with the numerical results in both time and frequency domain.
본 연구는 전기비저항 측정시 실험체 크기에 따른 영향에 대해 비저항추정모델을 이용한 해석적 검토를 목적으로 한다. 실험에서는 콘크리트 실험체를 제작하여 전극 간격별 겉보기 비저항 측정하였다. 측정된 겉보기 비저항은 실험체 크기가 작아지고 외측(가장자리)에 가까울수록 겉보기 비저항치의 왜곡현상이 심해진다는 것을 확인할 수 있었다. 측정치와 해석치의 비교·분석 결과, 실험체 크기의 영향성 검토에 REM이 활용될 수 있을 것으로 기대된다.
콘크리트 비저항에 대한 실험실 단위의 측정시, 실험체의 제한된 크기로 인해 겉보기 비저항은 측정위치에 따라 영향을 받게 된다. 콘크리트 실험체를 대상으로 한 비저항 측정에서 위치에 따른 영향을 분석하였으며 겉보기 비저항이 가장자리로 이동할수록 그 영향이 높게 나타난다는 것을 확인하였다. 콘크리트 비저항 추정의 정확성을 높이기 위해 이에 대한 사전 검토가 필요함을 알 수 있었다.
본 연구에서는 전기비저항에 대한 실험실 레벨의 측정에서 실험체 크기가 겉보기 비저항에 미치는 영향에 대해 검토하였다. 실험은 실험체의 측변과 높이가 다른 실험체를 제작하여 겉보기 비저항을 측정하였다. 실험결과, 실험체의 측변과 높이이 작을수록 겉보기 비저항이 크게 나타났다. 또한 전기비저항 측정에 미치는 실험체 크기의 영향은 선형적으로 나타나지 않음을 확인하였다.
Resistivity measurements are carried out on infinite isotropic media such as the surface of the earth. Since the concrete resistivity at the laboratory level is measured on specimens of a specific shape and size, it is necessary to examine the influence of the geometry of the specimen on the resistivity measurement. In this study, the influence of the shape of the concrete specimen on the apparent resistivity was investigated through experiments.
In this study, the behavior of column rebar in non-reinforced specimens (BF) was evaluated as part of the development of seismic retrofitting systems for public buildings such as school buildings. This is a very useful work because it can show the deformation state of the main bars according to the hysteretic behavior of lateral loads. When yielding the specimen, the main bar was yielded. and the deformation of stirrup at the inflection point position hardly occurred. These results will be used as a key index to evaluate the yield state of the structure from the deformation comparison of the reinforced specimens.
구조실험에서 정확성과 효율성을 높이기 위해서는 적절한 실험장치를 적용하는 것은 중요한 요소이다. 특히, 대규모의 구조실험에서 적절한 실험장치는 비용과 시간을 절감할 수 있다. 액츄에이터와 유압잭 및 UTM은 실험체의 휨 능력을 평가하는 데일반적으로 적용되고 있다. 그러나, 대규모 실험체에서 다점 다하중 가력하중이 적용되어야 하는 경우에는 기존의 UTM 등을이용하는 실험방법은 정확한 하중을 가력하기에 어려움이 많다. 이를 해결하기 위하여 본 연구에서는 실험결과의 정확성과 효율성을 높이기 위하여 기존의 실험장치로 조합된 새로운 방법을 개발하였다.
본 연구의 목적은 직접전단응력 및 휨 전단응력의 비교분석을 통하여 Perfobond Rib 전단연결재를 사용한 구조물의 하중방향에 따른 전단응력 분석이다. 직접전단응력 분석을 위해서 5개의 변수로 Perfobond Rib 전단연결재 실험체 5개를 제작하고Push-out Test를 실시하였다. 실험 후 Perfobond Rib 전단연결재의 전단저항 메커니즘을 규명하고, 직접전단응력에 영향을미치는 주요 인자를 바탕으로 직접전단력을 산출할 수 있는 제안식을 제시하였다. 또한 휨 전단응력의 분석을 위해 강-콘크리트 합성 바닥판 실험체를 제작하고 정적 휨실험을 실시하였다. 정적 휨실험을 바탕으로 휨 거동특성을 분석하고 휨 전단응력을계산하였다. 직접전단응력과 EN 1994-1-1을 통해 계산된 휨 전단응력을 비교하여 하중방향에 따른 전단저항응력에 대해서분석을 하였다.