        검색결과 21

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, in order to analyze the water purification efficiency according to the influent water conditions of artificial wetlands, the purification efficiency was compared at two points where sewage treatment water flows in and one point where good effluent flows in. As a result of reviewing the results of the analysis of influent and effluent and the removal efficiency, the T-N and T-P removal efficiency was calculated at 54.7% and 77.4%, respectively, for the two points where sewage treatment water was treated, the treatment efficiency of SS 90.8%, BOD 51.1%, TOC 30.6%, T-N 38.8%, T-P 55.3% was shown. As a result, the efficiency of removing pollutants in the artificial wetland was found to be proportional to the concentration of influent water, and in order to create an efficient artificial wetland, it is judged that thorough review and management at the design stage are necessary considering that the removal efficiency of high-concentration contaminated water was high.
        4,200원
        2.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.
        4,600원
        3.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Membrane distillation (MD) is a thermally driven desalination process with a hydrophobic membrane. MD process has been known to have a lower fouling potential compared to other pressure-based membrane desalination process (NF, RO). However, membrane fouling also occurs in MD process. In this study, the membrane fouling was observed in MD process according to the pre-treatment processes. The filtration and precipitation processes were applied as the pre-treatment to prevent the membrane fouling. The pore sizes of roughing filters were 0.4, 5, 10, 30, and 60 ㎛. The concentration of the coagulant was 1.2 mg/L as FeCl3. The membrane fouling on MD membrane was successfully removed with both pre-treatment processes.
        4,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Euiam and Paldang Reservoirs have often been facing water quality problems, such as eutrophication, algal blooms and off-flavors by treated wastewater effluent (TWE) in the North-Han and the Han River basins, but little is examined on the direct biological effect of TWE. This study tested algal growth potential (AGP) of four TWEs discharged into Euiam and Paldang Reservoirs to evaluate water fertility in September 2014 and March and September 2015. Test alga was used Anabaena circinalis isolated from Paldang Reservoir. Mean concentration of T-N and T-P in TWEs was 3,956.7 μg N L-1 and 50.8 μg P L-1, and the proportion of NO3-N and PO4-P to the total fraction was 72.1% and 40.8%, respectively. Both N and P were high in TWEs, but much higher N than P concentration indicates strong P-limitation. As a consequence, the maximum AGP was determined by PO4-P concentration (r=0.998, p<0.01). Mean AGP value was 15.4 mg dw L-1 among four effluents indicating its eutrophic condition. Due to the establishment of tertiary (advanced T-P) treatment method in the studied plants recently, P concentration was significantly decreased in TWEs compared to the years prior to 2012. However, P concentration seems to be still high enough to cause eutrophication and algal blooms. Therefore, wastewater treatment to P-free level needs to be considered if effluents are directly discharged into the drinking water resources.
        5,100원
        5.
        2016.11 구독 인증기관·개인회원 무료
        최근 셰일가스 산업의 호황과 더불어 셰일가스전에서 배출되는 폐수처리가 중요한 환경문제로 부각되고 있다. 셰일가스전 폐수는 총 용존고형물의 농도가 10에서 200g/L로 높기 때문에 역삼투 담수공정을 적용하기에 어려움이 있다. 본 연구에서는 셰일가스전 폐수를 처리하기 위해 저압에서 운전 가능한 정삼투 공정(FO)의 적용 가능성을 연구하였다. 특히 대표적으로 널리 활용되고 있는 유도용액인 NaCl과 NH3-CO2를 사용하여 셰일가스전 폐수에 포함되어 있는 2가 양이온이 FO공정에 미치는 영향을 알아보았다. FO공정 유도용액의 역확산은 막의 플럭스와 스케일로 인한 막오염에 중요한 영향을 끼치는 것으로 나타났다. 이를 통해 FO공정의 폐수 성상에 따라 유도용액 종류 선택 및 공정 디자인의 중요성이 입증되었다.
        6.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of UV254, dissolved organic carbon (DOC) and SUVA were interpreted.
        4,000원
        7.
        2015.05 구독 인증기관·개인회원 무료
        본 연구는 SWRO/PRO 조합공정에서 PRO 공정 유입수로써 적합한 유입수질 조건과 전처리 기술을 알아보고자 하였다. 실험에 사용된 유입수로는 P시의 하수처리장 방류수를 사용하였으며, 유도용매는 역삼투막 농축수를 활용하였고, 이때 사용한 PRO막은 Toray사의 CTA재질막을 사용하였다. 본 연구에서 응집-침전, 모래여과, DMF, 활성탄여과, 정밀여과공정, 역삼투공정 등 총 6가지 전처리공정을 선정하여 평가하였고, PRO 공정 성능에 영향을 크게 주는 것으로 확인하였다. 향후 SWRO/PRO 조합공정에서 안정적인 에너지 절감 효과를 기대할 수 있는 최적 공정을 도출할 계획이다.
        8.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, current sewer infiltration/Inflow(I/I) computation and application method was examined about improvement and adequacy relating to the main issues raised by the field for practitioners. The results of review about infiltration calculation method were considered to be in need of improvement at‘standards of minimum sewage calculation’. Furthermore, the results of review about I/I application method were considered to be in need of improvement at‘standards of seasonal infiltration application’and‘the relative decrease in the Annual evaluation standards’. In addition, annual I/I analysis at JC County for the four years(2009 ~ 2012) in respect of operation flow and rainfall data was conducted. The result of annual infiltration analysis, compared average daily sewage generated average infiltration rate was found in 21.95 %, infiltration by unit was found in 0.31 m3/day/cm/km and 0.12 m3/day/day, respectively. The result of annual inflow analysis, average rainfall - Inflow equations was found y = 5.499x(R2 0.793), and the average Inflow quantity by sewer extension was predicted to 0.66 m3/mm-km.
        4,500원
        10.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        11.
        1999.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        달방댐 3개 유입수의 연평균 총인 농도는 달방골, 서 학골 및 신흥골이 각각 7.7, 19.1 및 40.0 mgP/m3이었으며 신흥골 유입수가 상대적으로 높았다. 초기 강우시에는 유입수량 증가에 따라 총인 농도가 모두 증가하는 양의 관계를 보여주고 있으나 뒤이어 계속해되는 두번째 강우에서는 유입수량 증가와 크게 관련이 없는 것으로 나타났다. 강우가 집중되었던 1994년 10월 12일에 달방골 유입수의 초기 강우시 총인농도는 97.8 mgP/m3 이였으며, 서학골 유입수는 190 mgP/m3, 신흥골 유입수는 1,336 mgP/m3로 매우 높았다. 달방댐 표층(0~5m 평균)의 총인 농도는 1994년부터 점차 증가되어 1994년과 1995년 10월의 농도가 각각 26.0과 50.0 (3회 측정치 평균) mgP/m3으로 조사되었다. 달방댐에 유입되는 전체 총인 부하량은 각각 236.9 kgP/yr으로 계산되었으며 우기인 10월과 11월에 유입 되는 부하량이 전체 부하량의 71.0%인 167.8 kgP/yr이었다. 유역전체로 볼 때 신흥골 유역으로부터 부하되는 인부하량이 64.1%로 많은 것으로 나타났다. 인 발생부 하량은 2,216 kgP/yr로 계산되었으며, 유역에서 발생된 인이 호수까지 도달되는 도달율은 10.7%이었다. 본 연구결과 호수 수질을 관리하기 위해서는 강우, 특히 초기 강우시에 유입되는 오염물질의 양을 줄여야 할 것으로 사료된다. 이를 위해서는 유역에 산재해 있는 비점오염원인 가축 배설물과 농경지로부터 유출되는 인부 하량을 감소시킬 수 있는 방안이 수립되어야 할 것으로 보인다.
        4,000원
        13.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 IPCC가 발간한 AR5 의 시나리오 중 임의로 선택된 RCP 4.5와 RCP 8.5 기후변화 시나리오가 용담댐 유역과 호내의 유량과 수질변화에 미치는 영향을 분석 및 그 방법론을 수립하기 위해서 SWAT 모델과 CE-QUAL-W2 모델을 차례로 사용하였다. 기후변화 시나리오는 용담댐 유역에 대해 상세화 된 자료 를 사용하였으며 2016~2095년의 기간을 2016~2035년, 2036~2065년 그리고 2066~2095년의 세 가지의 기간으로 구분하고 또한 각 연도별로 5월과 10 월 사이의 우기(Wet Season)와 11월과 4월 사이의 건기(Dry Season)로 또한 구분하여 분석하였다. 전체 모의 기간에 대해 산술평균한 용담댐 유역의 유량과 TSS 및 TP는 RCP 4.5가 RCP 8.5 보다 큰 것으로 나타나고 TN의 경우 다른 경향을 나타내었다. 반면, 모델의 예측결과를 기간별 또는 연중 강우특성별로 구별하여 분석한 경우에는 각 경우마다 서로 다른 결과를 나타내고 있다. 기후변화 시나리오가 진행됨에 따라 전반적으로 강우일수는 감소하고 강우강도는 증가하여 갈수기에는 오염물질의 유출이 감소하고, 홍수기에는 오염물질의 유출이 증가하여 연간 오염물질 유출량이 홍수기에 집중되는 특성을 나타내었다. 상기와 동일 한 기간에 대해 SWAT 모델에서 생성된 유역의 자료를 CE-QUAL-W2 모델의 경계조건으로 사용하여 용담댐의 수질변화특성을 모의하였다. TSS와 TP농도는 하절기 강우량의 증가에 따라 특히, 높은 값을 나타내는 것으로 분석되었으나, 고형물질에 잘 흡착되지 않는 TN은 다른 경향이 나타났다. 따라서 기후변화에 의한 장래의 유량 및 수질 변화는 전반적인 경향과 더불어 지역적, 시기적 특성을 또한 반영하여 분석하는 것이 바람직하다고 판단되며 이에 따라 갈수 및 홍수에 의한 시기별, 지역별 유량 및 수질 관리 대책이 별도로 필요할 것으로 판단된다.
        15.
        2012.02 서비스 종료(열람 제한)
        정부는 하수관거의 대대적인 확충과 정비를 통하여 2010년 말 기준 하수도 보급률을 90.1% 수준으로 향상하였으며, 현재 운영 및 유지관리 단계에 접어들었으나 하수관거 운영성과 분석 및 평가를 위한 집수여건에 적합한 침입수와 유입수의 산정 방법에 대한 연구가 절실하다. 본 연구에서는 침입수와 유입수 산정 기법들의 특징을 분석하여 ‘물 사용량 평가법’과 ‘야간 생활하수 평가법’을 침입수 산정 방법으로 채택하였으며, 아산시를 연구 대상지역으로 선정하여 하수 유입수량 및 강우량 등 연구 자료를 수집하여 침입수와 유입수량을 산정하였다, 계산된 결과를 바탕으로 집수구역별 침입수 및 유입수 발생 특성과 연간 및 월간 구분에 의한 침입수 발생 특성, 계절별 침입수 발생 특성을 분석하였다. 합병식 하수배제 방식인 온천 집수구역과 분류식 하수배제 방식인 권곡 및 실옥 집수구역은 야간 생활하수 평가법에 의한 침입수 산정 방식이 효과적인 것으로 평가되었으며, 분류식 하수배제 방식인 모종 집수구역은 물 사용량 평가법과 야간 생활하수 평가법 모두 침입수 산정에 유효한 것으로 평가되었다. 또한, 주거지역인 모종 및 권곡 집수구역과 비교하여 상업지역이 많은 온천 집수구역의 침입수량 및 유입수량 산정 결과가 상대적으로 큰 것으로 나타났다. 결과적으로 상업시설을 이용하는 경제활동 인구가 많은 상업지역이 아파트단지 등 주거지역에 비해 인구수대비 하수 유입율이 평균 72% 많은 것으로 분석되었다. 또한 최대 하수유입량의 68.4%∼74.7% 범위에서 평균 하수유입량이 발생하는 것으로 평가되었으며, 강우에 따른 유입수량은 강우량과 비례하여 우기 및 건기 등 시간적 변화에 따라 크게 변동하였다. 본 연구에서는 집수구역에 따라 침입수 및 유입수의 발생 양상이 다른 것으로 분석되었다. 따라서, 지역 특성이 다른 하수관거 정비지역 선정을 위한 지역별 예상 하수 발생량, 침입수 및 유입수 산정 시는 물론 향후 하수관거 유지관리 및 운영 시에도 지역에 적합한 관리 방안 마련에 크게 활용될 수 있을 것으로 기대된다.