In this study, we propose a flow velocity evaluation scheme based on pressure measurement in pressurized pipeline systems. Conservation of mass and momentum equations can be decomposed into mean and perturbation of pressure head and flowrate, which provide the pressure head and flowrate relationship between upstream and donwstream point in pressurized pipeline system. The inverse impedance formulations were derived to address measured pressure at downstream to evaluation of flow velocity or pressure at any point of system. The convolution of response function to pressure head in downstream valve provides the flow velocity response in any point of the simple pipeline system. Simulation comparison between traditional method of characteristics and the proposed method provide good agreements between two distinct approaches.
In this work, measured data from thickness gauge behind of the finishing mill stand was used for increasing accuracy of thickness control in plate rolling process. The Automatic Gauge Control (AGC) system of the mill could control roll gap for the remaining rolling passes based on the difference between measured and calculated thickness. This work was possible with some modification in software product system to use measured data without additional installation of equipment. As a result, the accuracy of thickness has been increased up to 31%. The accuracy of thickness control was defined as a standard deviation of the differences between target and measured final thickness of average.
Green strength is an important property of powders since high green strength guarantees easy and safe handling before sintering. The green strength of a powder compact is related to mainly mechanical and surface characters, governed by interlocking of the particles. In this study, the effect of powder surface roughness on the green strength of iron powders was investigated using a transverse rupture test. Three-dimensional laser profiler was employed for quantitative analyses of the surface roughness. Two different surface conditions, i.e. surface roughness, of powders were compared. The powders having rough surfaces show higher green strength than the round surface powders since higher roughness leads increasing interlocked area between the contacting powders.
The synthesis behavior of nanoporous silica aerogel in the macroporous ceramic structure was observed using TEOS as a source material and glycerol as a dry control chemical additive (DCCA). Silica aerogel in the macroporous ceramic structure was synthesized via sono-gel process using hexamethyldiazane (HMDS) as a modification agent and n-hexane as a main solvent. The wet gel with a modified surface was dried at under ambient pressure. The addition of glycerol appears to give the wet gel a more homogeneous microstructure. However, glycerol also retarded the rate of surface modification and solvent exchange. Silica aerogel completely filled the macroporous ceramic structure without defect in the condition of surface modification (20% HMDS/nhexane at 36hr).
The purpose of this study was to identify the differences in pulmonary functioning after respiratory exercise with IPPB (Intermittent Positive Pressure Breather) in patients with progressive muscular dystrophy (PMD). The subjects were 46 patients with PMD who were admitted to the Rehabilitation Medicine Department of Youngdong Severance Hospital. The subjects were assigned into one of 2 groups. The control group received comprehensive treatments such as ROM exercise, deep breathing exercise, moist hot packs, and ultrasound twice a day while admitted at the Rehabilitation Medicine Department. Unlike the control group, the subjects at the experimental group received respiratory exercise treatment with IPPB. The subjects were admitted for 10~19 days, and the average length of hospital stay was 12.2 days. Pulmonary functioning was evaluated at admission and discharge by SENSOR MEDICS. The data were analyzed by a paired t-test and a independent t-test. The results were as follows: 1) The change of each parameter of pulmonary function tests were significantly improved in all groups after respiratory exercise treatment during admission (p<0.05). 2) By comparing the change of each parameter of pulmonary function tests between the experimental group and control group, the parameters of vital capacity (VC), forced vital capacity, forced vital capacity predicted (FVCP) and forced expiratory volume in 1 second (FEV1) were significantly improved in the experimental group which had received the pulmonary exercise treatment with IPPB (p<0.05). In conclusion, this study suggests that the pulmonary exercise treatments with IPPB facilitated improvement in the pulmonary functioning for the PMD patients during their hospital stay.
Aluminum was deposited on aluminum oxide powders using a fluidized bed reactor at atmospheric pressure. The aluminum oxide powders were irregular flakes with acute angles and the average particle size was 26 . The fluidized bed was formed by flowing argon gas at the velocity of 60 cm/sec. The optimal fluidization condition was obtained with the reactor designed to be tapered so that the fluid velocity decreases as the fluidizing gas goes up along the reactor. Aluminum was deposited by flowing TiBA(Triisobutylaluminum) evaporated at through the fluidized bed reactor heated to 350~. The result from the analysis by XRD and EDAX confirmed the coating of aluminum and an SEM micrograph showed the conformality.
거창지역의 쥬라기 화강암에서 발달하는 결과 평행한 압열인장강도(σt)의 특성을 분석하였다. 여섯 방 향의 결에 대한 평가는 미세균열의 길이와 위의 강도에 대한 파라미터의 값을 이용하여 수행하였다. 각 방향에 속하는 다섯 시험편의 강도값은 다섯 그룹으로 분류하였다. 이들 다섯 그룹의 강도값은 그룹 A < B < C < D < E의 순으로 증가한다. 위의 미세균열과 강도 사이의 밀접한 상관성을 도출하였다. 이 연구의 분석 결과는 다음과 같다. 첫째, 3개 결 사이의 강도의 변화 및 특성을 보여 주는 도면을 작성하였다. 위의 도면에 서는, 각 그룹에 속하는 여섯 방향의 강도값을 1번 결(리프트 1 및 리프트 2), 2번 결(그레인 1 및 그레인 2) 그리고 3번 결(하드웨이 1 및 하드웨이 2)의 순으로 배열하였다. 다섯 그룹의 강도분포선은 R1의 방향에 집중한다. 그래서 강도차(Δσt)를 지시하는 위의 다섯 선 사이의 폭은 R1 방향에서 가장 협소하다. 관련 도면으로부터, 각 결을 형성하는 두 방향 사이의 변화 특성을 도출하였다. 그레인 2(2)-시험편은 그레인 1(1)-시험편 에 비하여 보다 높은 강도값 그리고 보다 낮은 강도차값을 보여 준다. 이러한 현상은 시험편 H2(2)와 H1(1) 사이의 사례와 부합한다. 위의 시험편 (2)의 강도 특성은 시험편 (1)에 비하여 보다 낮은 미세균열의 밀도 그리고 하중 방향에 평행 배열하는 미세균열의 분포에 있어서의 보다 높은 균일도를 시사한다. 위의 도면에서는 각 그룹에 속하는 여섯 강도값이 증가하는 순으로 배열하였다. 그룹 D 및 E 양쪽에 속하는 시험편의 강도값은 R1 < R2 < G1 < H1 < G2 < H2의 순으로 나타난다. 따라서, 그룹 D 및 E의 강도값은 여섯 방향의 결의 평가를 위한 지시자값이 될 수 있다. 둘째, 경사각(θ)과 강도차 사이의 상관도를 작성하였다. 위의 두 파라미터의 값은 두 방향 사이를 연결하는 다섯 강도분포선을 통하여 획득하였다. 일번 면(그레인 1-하드웨이 1, R'), 2번 면(리프트 1-하드웨이 2, G') 및 3번 면(리프트 2-그레인 2, H')과 관련된 도면으로부터, 일차함수의 기울기값은 R'(0.391) < G'(0.470) < H'(0.485)의 순으로 증가한다. 3개 면 중에서, 3번 면과 관련된 도면은 다섯 그룹 사이의 가장 높은 분포밀도를 보여 준다. 1번 결(리프트 1-리프트 2, R), 2번 결(그레인 1-그레 인 2, G) 및 3번 결(하드웨이 1-하드웨이 2, H)과 관련된 도면으로부터, 일차함수의 기울기값은 R(0.407) < H(0.453) < G(0.460)의 순으로 증가한다. 3개 결 중에서, 일번 결과 관련된 도면은 하부 구간에 속하는 그룹의 가장 높은 빈도수를 보여 준다. 종합하면, 3개 면 · 3개 결 사이의 경사각의 분포 폭은 H' < G < R' < R < G' < H의 순으로 증가한다. 섯째, 미세균열의 길이와 관련된 파라미터 그리고 인장강도 사이의 상관성 분 석을 수행하였다. 이들 파라미터는 빈도수(N), 총 길이(Lt), 평균 길이(Lm), 중앙 길이(Lmed) 및 밀도(ρ)를 포 함할 수 있다. 위의 미세균열에 대한 개개 파라미터(X) 그리고 다섯 그룹에 해당하는 다섯 수준의 인장강도 (Y) 사이의 상관도를 작성하였다. 다섯 종류의 상관도로부터, 상관계수의 값(R2)은 다섯 수준의 강도와 함께 증가한다. 각 도면으로부터 도출한 다섯 상관계수의 평균값은 0.22(N) < 0.34(Lt) < 0.38(ρ) < 0.57(Lmed) < 0.58(Lm)의 순으로 증가한다. 넷째, 그룹 E에 해당하는 최대강도(X) 그리고 위의 다섯 파라미터(Y) 사이의 상 관도를 작성하였다. 관련 도면으로부터, 상관계수의 값은 0.61(N) < 0.81(Lt) < 0.87(ρ) < 0.93(Lm) < 0.96 (Lmed)의 순으로 증가한다. 가장 높은 상관성을 갖는 두 파라미터는 최대 강도와 함께 중앙 길이이다. 미세 균열과 강도 사이의 상기 상관성 분석을 통하여, 이 연구에서 도출한 결과물에 대한 신뢰성을 제고할 수 있다.
본 논문에서는 압분광법을 기반으로 강재에 작용하는 응력을 비파괴/비접촉식으로 측정할 수 있는 새로운 방법은 제안하고, 이에 대한 가능성을 실험적으로 검증하였다. 분광법은 일반적으로 대상물의 화학적 성분을 분석하는데 주로 사용되며, 토목분야에서는 강재의 부식을 판단하는데 일부 사용되고 있다. 압분광법은 대상물이 하중을 받을 때 측정된 스펙트럼이 하중이 없는 상태에서 측정된 스펙트럼으로부터 이동(Shift)되는 현상인, 압분광현상을 기반으로 응력을 측정하는 방법이다. 여기서, 응력-스펙트럼 이동 관계를 선형으로 가정하였을 때, 압분광 계수를 도출할 수 있으며, 이를 통하여 현재상태의 응력을 측정할 수 있다. 해당 기술은 레이저를 기반으로한 비접촉식 응력측정 기술로써, 최근에 철도 구조물에 대한 응력 측정을 시작으로 다양한 토목구조물의 응력측정에 대한 적용이 시도되고 있다. 본 연구에서는 이와 같은 압분광법 기술을 이용하여 강구조물의 응력을 측정할 수 있도록, 용사코팅을 이용하여 알루미나를 구조용 강재표면에 도포하고, 일축압축 하중시험을 수행하여 각 하중단계에서의 스펙트럼 이동(Shift)값을 확인하였다. 이를 통하여, 각 하중값과 스펙트럼 이동값이 선형관계임을 확인하였다. 따라서, 이와 같은 선형적인 관계로 부터, 1차 선형식의 상수값인 압분광 계수를 도출하고, 이를 통하여 강재에 작용하는 응력을 측정할 수 있을 것으로 기대된다.
The research measured cracks by visualizing them through mechano- luminescence(ML) paint. By applying M-L paint on the surface of the specimen and using the 3-point bending test. Through the results of this research, we confirmed the crack propagation speed by section and the mechanical correlation such as between loads and cracks and between deflection and cracks, which means this research was quite successful in analyzing the characteristics of cracks.