The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.
강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
A shake table test is conducted for the three-story reinforced concrete building structure using 0.28 g, 0.5 g, 0.75 g, and 1.0 g of seismic input motions based on the Gyeongju earthquake. Computational efforts are made in parallel to explore the mechanical details in the structure. For engineering practice, the elastic modulus of concrete and rebar in the dynamic analysis is reduced to 38% and 50%, respectively, to calibrate the structure's natural frequencies. The engineering approach to the reduced modulus of elasticity is believed to be due to the inability to specify the flexibility of the actual boundary conditions. This aspect may lead to disadvantages of nonlinear dynamic analysis that can distort local stress and strain relationships. The initial elastic modulus can be applied directly without the so-called engineering adjustment with infinite element models with spring and spring-dashpot boundary conditions. This has the advantage of imposing the system flexibility of the structure on the sub-boundary conditions of springs and damping devices to control its sensitivity in a serial arrangement. This can reflect the flexibility of realistic boundary conditions and the effects of system damping (such as the gap between a concrete footing and shake table, loosening of steel anchors, etc.) in scalar quantities. However, these spring and dashpot coefficients can only be coordinated based on experimental results, making it challenging to select the coefficients in-prior to perform an experimental test.
Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
An approximate analysis method is proposed to predict the dynamic amplification of shear forces in ordinary reinforced concrete shear walls as a preliminary study. First, a seismic design for three groups of ordinary reinforced concrete shear walls higher than 60 m was created on the basis of nonlinear dynamic analysis. Causes for the dynamic amplification effect of shear forces were investigated through a detailed evaluation of the nonlinear dynamic analysis result. A new modal combination rule was proposed on the basis of that observation, in which fundamental mode response and combined higher mode response were summed directly. The fundamental mode response was approximated by nonlinear static analysis result, while higher mode response was computed using response spectrum analysis for equivalent linear structural models with the effective stiffness based on the nonlinear dynamic analysis result. The proposed approximate analysis generally predicted vertical distribution of story shear and shear forces of individual walls from the nonlinear dynamic analysis with comparable accuracy.
Seismic performance of ordinary reinforced concrete shear wall systems commonly used in high-rise residential buildings is evaluated. Three types of shear walls exceeding 60m in height are designed by performance-based seismic design. Then, incremental dynamic analysis is performed collapse probability is assessed in accordance with the procedure of FEMA P695. As a result, story drift, plastic rotation, and compressive strain are observed to be major failure modes, but shear failure occur little. Collapse probability and collapse margin ratio of performance groups do not meet requirement of FEMA P695. It is observed that critical wall elements fail due to excessive compressive strain. Therefore, the compressive strain of concrete at the boundary area of the shear wall needs to be evaluated with more conservative acceptance criteria.
In this study, natural period formular is presented for a RC shear wall structure with H-, T-, and L-shaped wall sections. The natural period formular proposed by Goel and Chopra and adopted in ASCE 7-10 was modified by using the ratio of the flange and web wall area. The natural periods of structures with H-shaped wall were numerically obtained, the results indicated that the ASCE 7-10 could not consider the natural period variation according to the length of the flange wall, but the proposed formula could do. Especially, ASCE 7-10 estimated much longer periods than eigenvalue analysis, and this implies that conservative seismic design is difficult. The periods by eigenvalue analysis exist between the upper and lower bounds given by the proposed formula, and conservative design is possible by using the proposed lower bound value. In order to verity the effectiveness of the proposed method, actual residential buildings with various types of flange walls are considered. Ambient vibration tests, eigenvalue analyses, and nonlinear dynamic analyses were conducted and the periods were compared with the values by ASCE 7-10 and the proposed formula. The results showed that the proposed formula could estimate more accurately the periods than ASCE 7-10.
In this study, nonlinear finite element analysis based on the Modified Compression Field Theory has been conducted to evaluate shear strength of RC walls with opening. On the analysis, reinforcement ratio within development length of rebars nearby the opening was reduced in the model in order to investigate the effect of opening on shear strength of RC shear walls. The nonlinear finite element analysis has been verified through comparison with the test result in literature. Through the verification, it was investigated that the analysis considering the development length of rebars well reflected the effect of an opening on shear strength of RC shear walls while current design provisions did not reasonably consider one.
Reinforced concrete shear walls with deficient reinforcement details are tested under cyclic loading. The deficiency of reinforcement details includes insufficient splice length in U-stirrups at the ends of horizontal reinforcement and boundary column dowel bars found in existing low- to mid-rise Korean buildings designed non-seismically. Three test specimens have rectangular, babel and flanged sections, respectively. Flexure- and shear-controlled models for reinforced concrete shear walls specified in ASCE/SEI 41-13 are compared with the flexural and shear components of force-displacement relation extracted separately from the top displacement of the specimen based on the displacement data measured at diverse locations. Modification of the shear wall models in ASCE/SEI 41-13 is proposed in order to account for the effect of bar slip, cracking loads in flexure and shear. The proposed modification shows better approximation of the test results compared to the original models.
Reinforced concrete shear walls are effective for resisting lateral loads imposed by wind or earthquakes. Observed damages of the shear wall in recent earthquakes in Chile(2010) and New Zealand(2011) exceeded expectations. Various analytical models have been proposed in order to incorporate such response features in predicting the inelastic response of RC shear walls. However, the model has not been implemented into widely available computer programs, and has not been sufficiently calibrated with and validated against extensive experimental data at both local and global response levels. In this study, reinforced concrete shear walls were modeled with fiber slices, where cross section and reinforcement details of shear walls can be arranged freely. Nonlinear analysis was performed by adding nonlinear shear spring elements that can represent shear deformation. This analysis result will be compared with the existing experiment results. To investigate the nonlinear behavior of reinforced concrete shear walls, reinforced concrete single shear walls with rectangular wall cross section were selected. The analysis results showed that the yield strength of the shear wall was approximately the same value as the experimental results. However, the yielding displacement of the shear wall was still higher in the experiment than the analysis. The analytical model used in this study is available for the analysis of shear wall subjected to high axial forces.
This research presents the nonlinear analysis model for reinforced concrete shear wall systems with special boundary elements as proposed by the Korean Building Code (KBC, 2009). In order to verify the analysis model, analytical results were compared with the experimental results obtained from previous studies. Established analytical model was used to perform nonlinear static and dynamic analyses. Analytical results showed that the semi-special shear wall improved significantly the performance in terms of ductility and energy dissipation as expected based on previous test results. Furthermore, nonlinear incremental dynamic analysis was performed using 20 ground motions. Based on computer analytical results, the ordinary shear wall, special shear wall and newly proposed semi-special shear wall systems were evaluated based on the methods in FEMA P965. The results based on the probabilistic approaches accounting for inherent uncertainties showed that the semi-special shear wall systems provide a high capacity/demand (ACMR) ratio owing to their details, which provide enough capacity to sustain large inelastic deformations.
RC shear wall sections which have irregular shapes such as T, ㄱ, ㄷ sections are typically used in low-rise buildings in Korea. Pushover analysis of building containing such members costs a lot of computation time and needs professional knowledge since it requires complicated modeling and, sometimes, fails to converge. In this study, a method using an equivalent column element for the shear wall is proposed. The equivalent column element consists of an elastic column, an inelastic rotational spring, and rigid beams. The inelastic properties of the rotational spring represent the nonlinear behavior of the shearwall and are obtained from the section analysis results and moment distribution for the member. The use of an axial force to compensate the difference in the axial deformation between the equivalent column element and the actual shear wall is also proposed. The proposed method is applied for the pushover analysis of a 5- story shear wall-frame building and the results are compared with ones using the fiber elements. The comparison shows that the inelastic behavior at the same drift was comparable. However, the performance points estimated using the pushover curves showed some deviations, which seem to be caused by the differences of estimated yield point and damping ratios.
In this paper, analytical models for reinforced concrete shear wall systems designed based on Korean Building Code (KBC2009) are proposed, which have special and semi-special seismic details and are compared with experimental results for a verification of analytical models. In addition, semi-special seismic details aimed to improve constructability and enhance economic efficiency were proposed and evaluated. The analytical models were performed based on nonlinear static and dynamic analysis. Through the nonlinear analyses, two seismic details showed the similar seismic behavior from the cyclic test and the analytical models for the two different seismic details represented the behavior in terms of the initial stiffness, maximum strength and strength degradation. And newly proposed seismic details(semi-special) provided with similar hysterestic behavior as well as the maximum drift.
경계요소를 가지는 철근콘크리트 전단벽의 비선형 해석을 위한 간편 모델을 제안하였다. 이 간편 모델은 전단벽의 휨 및 전단 거동을 스프링요소로 나타낸 거시적 모델이다. 휨거동은 벽체의 단면해석을 기초로 한 모멘트강도와 회전능력을 벽체 양단의 수직 스프링요소로 나타내었다. 경계요소를 가지는 전단벽은 휨거동에 의해 지배되므로 전단거동은 휨거동에 바탕하여 변수를 계산하였고 중앙부 수평 스프링요소로 나타내었다. 제안된 모델은 전단벽 정적이력시험 결과와 비교한 후 비선형동적해석을 수행하여 사용된 이력법칙 및 변수들의 타당성을 조사하였다. 비선형동적해석을 이용한 변수연구를 통하여 내진성능평가의 주요변수인 요구값과 성능값에 미치는 영향을 검토하였다. 그 결과 전단력-전단변형 관계에서 약간의 차이가 있지만 전단벽의 전체거동은 잘 일치하였으며, 주요 변수의 변화에 대해 요구값과 성능값도 일정하게 변화하므로 제안된 해석모델은 경계요소를 가진 철근콘크리트 전단벽에 알맞은 것으로 판단된다.
지진취약도 분석은 원자력 발전소의 내진성능평가를 위하여 발전되어져 왔지만, 현재는 적용성이 건물과 교량 등에도 확대되어지고 있다. 일반적으로 지진취약도 곡선은 수많은 지진가속도 기록을 이용하여 비선형 시간이력해석으로 구한다. 비선형 시간이력해석에 의한 지진취약도 분석은 구조물의 모델링과 해석에 많은 시간이 소요되는 과정을 요구한다. 비선형 시간이력해석의 이와 같은 약점을 보완하기 위해서 변위계수법과 역량스펙트럼 방법과 같은 간단한 해석방법을 지진취약도 분석에 적용하였다. 변위계수법과 역량 스펙트럼 방법을 적용한 지진취약도 곡선의 정확성을 평가하기 위하여, 철근콘크리트 전단벽 구조물에 대한 변위계수법과 역량스펙트럼 방법을 적용한 지진취약도 곡선을 비선형 시간이력해석에 의해 구해진 지진취약도 곡선과 비교하였다. 지진취약도 곡선의 작성을 위해서는 설계스펙트럼에 대응되는 190개의 인공지진과 Shinozuka 등이 제안한 방법이 적용되었다.
이 연구에서는 평면, 입면 및 구조적 특성이 다양한 철근 콘크리트 고층 아파트 건물의 고유주기를 예측할 수 있는 새로운 식을 제안하였다. 제안식은 벽체의 진동이론과 지진시 계측된 건물들의 고유주기로부터 개발 되었으며, 평면에서 다양한 방향으로 설계된 전단벽의 구조적 특성을 적절히 반영할 수 있다. 제안식의 검증을 위해 신축 중인 국내 아파트 건물 10개동의 고유주기를 측정하였으며, 측정된 고유주기는 제안식 및 KBC 2009, ASCE 7-10과 같은 기준식들과 비교 하였다. 비교 결과, 제안식은 기준식에 비해 최근의 철근콘크리트 전단벽 건물 특성을 합리적으로 반영함으로써 고유주기를 보다 정확하게 예측하는 것으로 나타났다.
본 연구에서는 전단벽-모멘트골조 시스템으로서 전단벽이 주로 횡력을 부담하는 철근콘크리트 건물을 대상으로 다양한 설치형식과 마찰력의 총량 및 분포를 갖는 마찰형 감쇠기의 제진보강 효과를 수치해석을 통해 비교 분석하였다. 감쇠기의 설치형식으로서 전단벽에 인접한 대각가새형, 벽체가 없는 골조를 보강하는 대각가새형 및 벽체 단부를 보강하는 수직경계요소형을 고려하였다. 하중기준 강화로 설계용보다 크게 증가한 지진하중에 대해 건물의 재료비선형성을 고려한 비선형시간이력해석을 수행하여 에너지소산, 횡하중 및 부재손상도 측면에서 마찰형 감쇠기의 제진성능을 비교 분석하였다. 기준마찰력의 30% 수준의 총마찰력을 갖는 벽체보강 대각가새형 설치형식이 전반적으로 가장 우수한 제진성능을 보이며,이 경우에 마찰력 배분방식은 중요하지 않았다. 또한 일부층에 집중설치함으로써 전층설치에 약간 못미치는 제진성능을 얻을 수 있었다.
본 연구의 목적은 하부층에 필로티 구조, 상부층에 전단벽식구조를 가진 저층 철근콘크리트 건물의 내진설계 및 내진성능 평가를 위한 기본적인 자료를 제공하는 것으로서, 비선형 지진응답해석을 실시하여 각 층의 내력과 연성율 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 검토하였다. 본 연구에서는 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 특성을 2질점계로 치환하였으며, 하부층인 필로티 구조는 휨파괴형으로 상부층인 전단벽식 구조는 전단파괴형 시스템으로 각각 모델링하였다. 또한 각층의 복원력 특성으로는 필로티 구조는 Degrading Trilinear Model(휨파괴형), 상부층은 Origin Oriented Model(전단파괴형)을 선정하였다. 상기 복원력 특성은 각 층의 보유내력에 의하여 변화를 하며, 지진응답해석용 입력지진파로는 8개의 피해지진의 가속도 성분을 선정하여 이들 가속도 성분의 최대가속도를 0.1g, 0.2g, 0.3g로 표준화 하였다. 각각 지진강도수준에 따라 지진 응답해석을 실시하여 하부층 필로티 구조와 상부층 전단벽식 구조의 내력비와 응답 연성율 사이의 상관관계를 파악하였다. 최종적으로 특정 연성율을 위한 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력을 산정하여 요구내력 스펙트럼(Required Strength Spectrum)을 제안하였다. 본 연구에서 제안한 요구내력스펙트럼은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성율 이내로 머물게 하는 하한내력의 범위를 파악할 수 있는 등, 연구결과는 필로티 구조를 가진 철근콘크리트 전단벽식 건물의 내진성능평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 사료된다..2-propanedial 1.5 M 실험구에서는 실험개시시 30\;{\times}\;10^4\;cell/ml이던 것이 3 일 후 138\;{\times}\;10^4\;cell/ml였고, 실험종료시인 5 일 후에는 385\;{\times}\;10^4\;cell/ml로 증식되어 가장 높은 증식률을 보였다. 참굴 D상 유생을 대상으로 먹이효과를 조사한 결과 실험구와 대조구간 유생의 성장 및 생존율에 유의한 차이를 보이지 않았다.C에서 73.3%, 10^{\circ}C에서 63.3% 및 5^{\circ}C에서 56.7%로 수온이 30^{\circ}C 이내에서는 높을수록 높은 경향을 보였다. 염분에 따른 잠입 실험 결과는 실험 개시 300분 경과 후 염분 30 psu에서 93.3%로 가장 높았고, 35 psu에서 90.0%, 25 psu에서 83.3%, 20 psu에서 60.0%, 15 psu 이하에서는 거의 잠입이 이루어 지지 않았다. 따라서, 적정 살포를 위한 잠입률은 치패의 크기와 상관없이 저질종류는 모래 (75%) + 뻘 (25%), 입자크기는 1 mm 모래에서 높게 나타났다. 공기 중 노출시간은 짧을수록, 수온은 30^{\circ}C 이내에서 높을수록, 염분은 20-35 psu 이내에서 높을수록 잠입률이 높은 경향을 나타내었다. 교수학습모형에 관련된 지식을 묻는 내용으로 주로 출제되었다. 이에 구체적인 개선방안으로 특정 교수학습모형의 이론적 토대가 되고 전체적인 교수설계를 하기 위한 기본 바탕이 될 수 있는 교수학습이론에 관한 내용, 또한 현재가정과교육에
이 논문에서는 단조증가하중 하에서 철근콘크리트 전단벽의 수치해석을 위해 개발된 재료모델을 반복하중을 포함한 일반적인 하중 하에서의 구조 거동을 효과적으로 모사하기 위한 해석모델로 확장하여 제안하고 있다. 먼저 재료모델을 구성함에 있어 하중이력에 따라 인장과 압축이 교대로 작용하는 콘크리트는 기본적으로 회전균열모델을 따르는 직교이방성 재료로써 가정하였고, 직교하는 축에 대해 인장과 압축을 오가는 이력곡선을 중심으로 등가의 일축응력-변형률 관계를 정의하였다. 나아가 철근은 평균응력-변형률 개념을 통해 단조증가 상태의 응력-변형률 관계를 구성하였고, 역전된 반복하중으로 인해 발생하는 Bausc-hinger 효과를 고려하여 이력곡선을 정의하였으며, 전단 효과를 고려하기 위해 전단지간 비에 따라 기존에 제안된 이력곡선을 수정하였다. 특히 해석과정의 효율성을 도모하고 변형연화 거동특성 등 일반적인 하중-변위 평형경로를 갖는 철근콘크리트 구조물의 비선형 해석을 위해 arc-length 기법을 도입하였다. 또한 제안된 수치해석모델에 대한 효율성을 검증하기 위해 요소단위의 철근콘크리트 판넬 시험체와 대표적인 전단벽 시험체의 반복하중 이력에 따른 하중-변위 관계 등 전단에 의해 지배를 받는 구조체에 대한 해석 결과와의 비교가 이루어졌다.
이 논문에서는 패널, 깊은 보 그리고 전단벽과 같이 평면응력상태하에 있는 철근콘크리트 구조물의 비선형 유한요소해석에 있어서의 직교이방성 콘크리트 구성 모델의 적용성을 보여준다. 등가의 일축 변형을 개념을 토대로 콘크리트의 구성 관계가 주변형률 축과 일치하고 하중이력에 따라 회전하는 직교하는 축에 대해 제시된다. 제안된 모델은 이축 압축응력상태와 인장-압축 응력상태에서 각각 압축강도의 증가와 인장 저항력의 감소효과를 보여주는 이축 파괴영역의 정의를 포함한다. 인장균열이 발생한 후, 콘크리트의 압축강도의 감소효과가 제시되고, 인장강화효과로 알려진 철근에 의해 지지되는 콘크리트의 인장응력이 고려된다. 평균응력과 평균변형률 개념을 사용하여 힘의 평형, 적합조건 그리고 철근과 철근을 둘러싼 콘크리트 사이의 부착응력-슬림 관계를 토대로 인장강화효과를 모사하기 위한 모델이 제안된다. 유한요소 모델에 의한 예측은 유용한 실험자료와의 비교에 의해 입증된다. 이 논문에서는 해석결과와 이상화한 전단 패널실험으로부터 얻어진 실험값의 비교연구가 수행되고, 제안된 모델의 타당성을 보여주기 위해 서로 다른 응력상태하의 전단 패널 보와 벽체의 힘-변위 관계를 평가하였다.