        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.
        4,000원
        2.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In seismic design standards such as KDS 41 17 00 and ASCE 7, three procedures are provided to estimate seismic demands: equivalent lateral force (ELF), response spectrum analysis (RSA), and response history analysis (RHA). In this study, two steel special moment frames (SMFs) were designed with ELF and RSA, which have been commonly used in engineering practice. The collapse probabilities of the SMFs were evaluated according to FEMA P695 methodology. It was observed that collapse probabilities varied significantly in accordance with analysis procedures. SMFs designed with RSA (RSA-SMFs) had a higher probability of collapse than SMFs designed with ELF (ELFSMFs). Furthermore, RSA-SMFs did not satisfy the target collapse probability specified in ASCE 7-16 whereas ELF-SMFs met the target probability.
        4,000원
        3.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.
        4,000원
        4.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor(R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.
        4,000원
        5.
        2010.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        안전한 내진설계를 위해서는 부재에 요구되는 소성변형을 평가하여야 한다. 본 연구에서는 복잡한 비선형해석없이 탄성 해석결과에 근거하여 이중골조의 부재소성변형을 평가할 수 있는 빠르고 간편한 방법을 개발하였다. 보, 기둥, 벽체 등의 소성변형은 부재강성, 층간변위비, 모멘트 재분배, 단면치수 및 소성힌지 위치의 함수로 결정된다. 벽체와 보가 모멘트 접합된 경우에는 벽체의 소성변형에 의한 로킹효과를 고려하여 증가된 소성변형을 구한다. 8층 이중골조에 대하여 제안된 방법을 적용하였고, 비선형해석을 통하여 제안된 방법의 정확성을 검증하였다. 제안된 방법은 단순계산으로 부재소성변형을 합리적으로 예측하지만, 정확한 부재소성변형 평가를 위해서는 비탄성 층간변위비의 정확한 예측이 필요한 것으로 나타났다. 제안된 방법은 향후 성능중심 내진설계에 활용할 수 있을 뿐만 아니라 기존 건물의 성능평가에도 활용될 수 있을 것이다.
        4,200원
        6.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 철근콘크리트 특수모멘트골조(SMF)내 보-기둥 접합부의 비탄성 회전능력에 대한 연구결과를 조사한 것이다. 모든 실험체들은 ACI 318-02에 정의된 설계 및 세부지침에 따라 특수모멘트골조로 분류되었다. AISC(2002)기준에서 모멘트골조의 접합부에 대한 내진성능의 만족 기준을 이용하여 보-기둥 접합부를 평가하였다. 총 39개의 실험체들에 대해 자세하게 조사되었다. 특수모멘트골조에 대한 내진설계기준을 만족하는 대부분의 접합부들은 3%의 소성회전까지 휨강도의 심각한 감소 없이 연성이 유지되었다. 이는 특수모멘트골조 접합부들에 대한 엄격한 콘크리트 내진설계 규정에 따른 것으로 조사되었다. 접합부내의 횡방향 보의 존재는 보-기둥 접합부의 구속력과 전단에 대한 저항성을 증가시킨 것으로 조사되었다 접합부 전단응력에 대한 ACI 328-02 제한조건을 만족하는 모든 특수모멘트골조의 접합부들은 요구되는 내진성능을 만족하는 것으로 나타났다.
        4,000원
        7.
        2007.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 확률과 신뢰성을 바탕으로 개발된 FEMA-355F의 내진성능 평가기법을 적용하여 철근 콘크리트 모멘트골조 건물의 내진성능을 평가하였다. 철골 구조물을 대상으로 개발된 FEMA의 성능평가 방식을 다른 구조 시스템에 적용할 때 각 시스템에 적합한 성능값을 결정해야하며, 요구값과 성능값 계산 시 수반되는 불확실성을 반영하는 계수들을 새로이 구해야 한다. 이를 수행하기 위해 예제 건물을 IBC 2003에 따라 설계한 후, 성능평가에 필요한 변수들을 결정하기 위해 건물의 위치에 적합한 지반운동을 이용하여 비탄성 동적 해석을 수행하였다. 해석결과에 따르면 계산된 성능값의 분포는 요구값에 비해 상대적으로 작았으며, 이 결과는 본 연구에서 결정된 성능값이 합리적임을 나타낸다. 구해진 신뢰도는 부분 및 전체 붕괴 모두에 대해 목표치를 초과하였으므로 예제 건물은 목표 성능을 만족하는 것으로 나타났다.
        4,000원
        8.
        2005.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건축 구조물의 내진 설계는 탄성 정적 방법에 기초하고 있으나, 강진시 구조물의 실제 거동은 비탄성 동적이기 때문에 설계 규준의 적합성을 판단하기 위해서는 비탄성 동적 해석이 요구된다. 본 논문에서는 철근 콘크리트 특수 모멘트 저항 골조 건물을 선택하여 IBC 2003에 따라 설계한 후, 선택된 부재들의 최대 소성 회전, 소산 에너지를 구하여, 건물의 비탄성 거동이 규준에서 의도한 거동을 보이는 지를 검토함과 동시에 층간변위률 요구값을 구하여 설계 한도를 만족하는 지를 조사하였다. 더불어 비횡력 저항 시스템인 내부 모멘트 저항 골조의 해석시 포함 여부의 영향도 함께 조사하였다. 해석 결과 IBC 2003에 의해 설계된 건물은 규준이 의도한 비탄성 거동을 보여주었으며 층간변위률 또한 설계한도를 만족하였다. 그리고, 내부 모멘트 저항 골조는 지진 해석 결과에 중요한 영향을 미치므로 해석 모델에 반드시 포함되어야 함을 알수 있었다.
        4,000원